AD8036/AD8037
Operation of the AD8036 for negative input voltages and nega-
tive clamp levels on V
L
is similar, with comparator C
L
control-
ling S1. Since the comparators see the voltage on the +V
IN
pin
as their common reference level, then the voltage V
H
and V
L
are
defined as “High” or “Low” with respect to +V
IN
. For example,
if V
IN
is set to zero volts, V
H
is open, and V
L
is +1 V, compara-
tor C
L
will switch S1 to “C,” so the AD8036 will buffer the
voltage on V
L
and ignore +V
IN
.
The performance of the AD8036 and AD8037 closely matches
the ideal just described. The comparator’s threshold extends
from 60 mV inside the clamp window defined by the voltages on
V
L
and V
H
to 60 mV beyond the window’s edge. Switch S1 is
implemented with current steering, so that A1’s +input makes a
continuous transition from say, V
IN
to V
H
as the input voltage
traverses the comparator’s input threshold from 0.9 V to 1.0 V
for V
H
= 1.0 V.
The practical effect of these nonidealities is to soften the transition
from amplification to clamping modes, without compromising
the absolute clamp limit set by the CLAMPIN circuit. Figure 7
is a graph of V
OUT
vs. V
IN
for the AD8036 and a typical output
clamp amplifier. Both amplifiers are set for G = +1 and V
H
= 1 V.
The worst case error between V
OUT
(ideally clamped) and V
OUT
(actual) is typically 18 mV times the amplifier closed-loop gain.
This occurs when V
IN
equals V
H
(or V
L
). As V
IN
goes above
and/or below this limit, V
OUT
will settle to within 5 mV of the
ideal value.
In contrast, the output clamp amplifier’s transfer curve typically
will show some compression starting at an input of 0.8 V, and
can have an output voltage as far as 200 mV over the clamp limit.
In addition, since the output clamp in effect causes the am-
plifier to operate open loop in clamp mode, the amplifier’s out-
put impedance will increase, potentially causing additional errors.
The AD8036’s and AD8037’s CLAMPIN input clamp architec-
ture works only for noninverting or follower applications and,
since it operates on the input, the clamp voltage levels V
H
and
V
L
, and input error limits will be multiplied by the amplifier’s
A
B
C
S1
R
F
140
A B C
0 1 0
1 0 0
0 0 1
S1
V
IN
> V
H
V
L
≤ V
IN
≤ V
H
V
IN
< V
L
–V
IN
+V
IN
V
H
V
L
V
OUT
+1
+1
+1
C
H
C
L
A1
A2
+1
Figure 6. AD8036/AD8037 Clamp Amp System
0 5 10 15 20 25
R
SERIES
–
C
L
– pF
40
30
20
10
Figure 5. Recommended R
SERIES
vs. Capacitive Load
INPUT CLAMPING AMPLIFIER OPERATION
The key to the AD8036 and AD8037’s fast, accurate clamp and
amplifier performance is their unique patent pending CLAMPIN
input clamp architecture. This new design reduces clamp errors
by more than 10× over previous output clamp based circuits, as
well as substantially increasing the bandwidth, precision and
versatility of the clamp inputs.
Figure 6 is an idealized block diagram of the AD8036 connected
as a unity gain voltage follower. The primary signal path com-
prises A1 (a 1200 V/µs, 240 MHz high voltage gain, differential
to single-ended amplifier) and A2 (a G = +1 high current gain
output buffer). The AD8037 differs from the AD8036 only in
that A1 is optimized for closed-loop gains of two or greater.
The CLAMPIN section is comprised of comparators C
H
and
C
L
, which drive switch S1 through a decoder. The unity-gain
buffers in series with +V
IN
, V
H
, and V
L
inputs isolate the input
pins from the comparators and S1 without reducing bandwidth
or precision.
The two comparators have about the same bandwidth as A1
(240 MHz), so they can keep up with signals within the useful
bandwidth of the AD8036. To illustrate the operation of the
CLAMPIN circuit, consider the case where V
H
is referenced to
1 V, V
L
is open, and the AD8036 is set for a gain of +1, by con-
necting its output back to its inverting input through the recom-
mended 140 Ω feedback resistor. Note that the main signal path
always operates closed loop, since the CLAMPIN circuit only
affects A1’s noninverting input.
If a 0 V to 2 V voltage ramp is applied to the AD8036’s +V
IN
for the connection just described, V
OUT
should track +V
IN
perfectly up to 1 V, then should limit at exactly 1 V as +V
IN
continues to 2 V.
In practice, the AD8036 comes close to this ideal behavior. As
the +V
IN
input voltage ramps from zero to 1 V, the output of the
high limit comparator C
H
starts in the off state, as does the out-
put of C
L
. When +V
IN
just exceeds V
IN
(ideally, by say 1 µV,
practically by about 18 mV), C
H
changes state, switching S1
from “A” to “B” reference level. Since the + input of A1 is now
connected to V
H
, further increases in +V
IN
have no effect on the
AD8036’s output voltage. In short, the AD8036 is now operat-
ing as a unity-gain buffer for the V
H
input, as any variation in
V
H
, for V
H
> 1 V, will be faithfully reproduced at V
OUT
.