AZ40029

SOCKETS
L socket
Socket with cord
Socket with LED
14.8 dia.
M121.25
Rubber
13
3
5
1
2
14.8
10
14.8
15.6
22.5
(
32.5
)
(
2.4
)
t=0.5±0.2
Head section
M8
packing
(
1.280
)
(
.094
)
.583
.394
.583
.197
.512
.614
.886
.583 dia.
Terminal case
Terminal body
Rubber packing
Socket fastening screw
Waterproof ring
Hexagonal nut
Terminal receptacle
9.5
5
1
3
7.5
23
2
8.7
(
2.4
)
Cord
Rubber packing
14.8
2
16.5
Approx.
20±3
8±2
(
.094
)
.197
.374
.906
.583
.343
.295
.650
.079
.787±.118
.315±.079
(
t=0.5±0.2
)
1000
39.370
Waterproof ring
Socket fastening screw
Cord
(PVC)
Socket body
Rubber packing
1.5 max.
1
32
3.8
LED
(
Red
)
Cord
3.8
9.5
5
7.5
23
8.7
(
2.4
)
Rubber packing
14.8
2
16.5
Approx.
20±3
8±2
(
.094
)
.197
.374
.906
.583
.343
.295
.650
.079
.787±.118
.315±.079
(
t=0.5±0.2
)
1000
39.370
.150
.150
.059
AZ3806
AZ3807 (cord length: 1m)
weight: 85g
AZ380716 (cord length: 1m)
Terminal number Terminal
1 COM
2 N.C.
3 N.O.
Terminal number Cord color Terminal
1 B (Black) COM
2 R (Red) N.C.
3 W (White) N.O.
Terminal number Cord color Terminal
1 B (Black) COM
2 R (Red) N.C.
3 W (White) N.O.
General tolerance: ±0.4 ±.016
General tolerance: ±0.4 ±.016
General tolerance: ±0.4 ±.016
LAMP LIGHTING CIRCUIT
1. Load at N.O. side
Use normally open (N.O.) connection ter-
minal. LED will be turned on when switch
is in free position, when switch is on,
LED will be turned off.
2. Load at N.C. side
Use normally closed (N.C.) connection
terminal. LED will be turned off when is
in free position, when switch is on, LED
will be turned on.
3 N.O.
Load
+
DC power source
2 N.C.
COM
1
LED
+
DC power source
LED
Load
2 N.C.
3 N.O.
1
COM
Notes)
1. Keep possible leakage current (see the CAUTIONS)
in mind in order to prevent the load from malfunc-
tioning.
2. Types with the 24 to 48V DC lamp rating are recom-
mended for sequencer input use.
3. Connect the red and black leads to the positive
B
and negative v terminals, respectively, for the N.C.
type, and the white and black leads to the positive
B and negative v terminals, respectively, for the
N.O. type.
LED lamp
Socket body
Rubber
packing
Cord
(PVC)
Waterproof ring
Socket fastening screw
QL (AZ4)
mm inch
All Rights Reserved © C
OPYRIGHT Panasonic Electric Works Co., Ltd.
MOUNTING METHOD
1. L socket type
1) After loosening the L socket fastening
screws, grasp the terminal cover and pull
it away from the switch body.
2) Remove the fastening screw from the
terminal block. (Remove with the 3 termi-
nal receptacle.)
3) Loosen the hexagonal nut and
remove the rubber bushing and washer
from the inside.
4) Select cord from applicable wire table.
5) Decide which direction the cord outlet
is to face and strip the sheath according-
ly. (See page 43.)
6) After passing the applicable cord
through the hexagonal nut, bushing, and
washer in that order, pass the cord
through the terminal case.
7) After stripping the cord sheath, insert
the corresponding wires into the grooves
of the terminal body up to the wire stop,
then crimp the terminal receptacle over
the wires with a pair of pliers.
8) After the terminals have been properly
crimped in the terminal body, insert the
body into the terminal case. (When
inserting the body, be careful not to block
the hole for the fastening screw with the
wires.)
9) Temporarily screw in the fastening
screw through the terminal body, then
insert the washer and rubber bushing
into the cord opening of L socket.
Tighten it with a wrench or pliers.
10) Apply the rubber packing over the
terminals, then insert the L socket into
the switch body.
11) Tighten the fastening screw into the
switch body.
2. Socket with cord (including socket
with lamp)
1) Apply the rubber packing over the ter-
minals, then insert the socket with cord
into the switch body.
2) Screw the socket fastening screw into
the switch body and tighten it.
Mounting
The QL micro limit switch is manufac-
tured with a very small variation in the
distance between the datum plane and
the operating point. When the operating
point has been accurately established
and the mounting position clearly deter-
mined, two M4 bolts should be used
securely fastening the switch.
Pull away from the body.
Turn counterclockwise.
Terminal receptacle
Terminal body connection diagram
Turn counterclockwise.
Clockwise direction
Clockwise direction
Operating position
M4 fastening bolts
Mounting
Mounting plate
datum plane
(
O.P.
)
Lead wire stop
Terminal body
Terminal receptacle
Lead wire
QL (AZ4)
All Rights Reserved © C
OPYRIGHT Panasonic Electric Works Co., Ltd.
22.5
Standard
A
Packaging
condition
CORD OUTLET DIRECTION AND SHEATH STRIPPING DIMENSIONS
The cord outlet direction is selected from (1) of the (4) drawings below, and the cord is stripped to match the desired dorection
Aplicable wire
CAUTIONS
QL
L socket
direction
Cord sheath
stripping
dimensions
Wire name
Vinyl cabtire cord (VCTF)
Applicable wire
Conductor Wire strand Finished outside diameter
0.75 mm
2
2-wire 6.6mm .268 inch dia.
3-wire 7.2mm .283 inch dia.
Note: The stripping of the cord is
based on a length for dimension
A as standard and should be
stripped accordingly.
1
AZ3806
23
BA
22
(
COM
)
To
(
2
)
To
(
1
)
To
(
3
)
16
(
N.O.
,
N.C.
)
.866
.630
(1) (2) (3) (4)
Terminal (1) and (A) direction are aligned.
32
1
AZ3806
A
B
16
(
COM
)
To
(
3
)
To
(
2
)
To
(
1
)
.630
22
(
N.O.
)
.866
14
(
N.C.
)
.551
Terminal (3) and (A) direction are aligned.
1
AZ3806
23
AB
14
(
COM
)
16
(
N.O., N.C.
)
To
(
1
)
To
(
2
)
To
(
3
)
.551
.630
Terminal (1) and (B) direction are aligned.
1
AZ3806
32
A
B
To
(
2
)
16
(
COM
)
To
(
3
)
To
(
1
)
22
(
N.C.
)
.866
.630
14
(
N.O.
)
.551
Terminal (2) and (A) direction are aligned.
1. Ambient conditions
1) The use of these switches under the
following conditions should be avoided. If
the following conditions should become
necessary, we recommend consulting us
first.
Use where there will be direct contact
with organic solvents, strong acids or
alkalis, or direct exposure to their
vapors.
Use where inflammable or corrosive
gases exist.
2) Because these switchies are not of
water resistant or immersion-proof con-
struction, their use in water or oil should
be avoided. Also, locations where water
or oil can normally impringe upon the
switch or where there is an excessive
accumulation of dust should be avoided.
2. Wiring
1) Although QL limit switches have large
over-travel (O.T.), excessive O.T. will
occur wear and change in its characteris-
tics. Specifically, where there is a need
for long life, it is recommended that the
proper O.T. should be used.
When the operating object is in the free
condition, force should not be applied
directly to the actuator.
2) Use their own accessories when
mounting and wiring QL limit switches so
as to maintain their own characterisrics.
3) In order to maintain the reliability at a
high level under practical conditions of
use, the actual operating conditions
should be checked for the benefit of the
quality of the product.
4) Do not use the switch in a silicon
atmosphere. Case should be taken
where organic silicon rubber, adhesive,
sealing material, oil, grease or lead wire
generates silicon.
5) Avoid use in excessively dusty envi-
ronments where actuator operation
would be hindered.
3. Socket with LED
1) The OFF condition leakage current at
each voltage is as follows.
2) Even the polarity of power source is
connected in the opposite way, LED is
not broken. However, LED is not lit on.
Rated operating
voltage
6V 12V 24V 48V
24 to 48V DC ––1.6mA 3.2mA
12V DC 2.6mA 5.2mA
6V DC 2.5mA 5.6mA ––
QL (AZ4)
All Rights Reserved © C
OPYRIGHT Panasonic Electric Works Co., Ltd.

AZ40029

Mfr. #:
Manufacturer:
Panasonic
Description:
SWITCH SNAP ACTION SPDT 5A 125V
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet