7
Technical Data 10164
Effective September 2015
Bussmann series
500 Volts gG/gL NH Fuse links
EATON www.eaton.com
Time-current curves - NH Size 0
TIME (Seconds)
CURRENT (Amperes)
684268 2 648 246
10 100 1000
2
6
4
0.1
0.01
1
6
4
2
6
2
4
10
100
6
4
2
6
4
2
6
4
2
1 000
10 000
32
35
40
50
63
80
100
125
160
16
10
20
25
6
Technical data - NH size 0
Part numbers
with metal
gripping lugs
Fuse link
size
Rated
current
(Amps)
Rated
voltage
(V a.c.)
I
2
t (Amps
2
Seconds)
Watts loss
Net weight
per fuse
(kg)
Minimum
pre-arcing
*I
1
120kA
at 500 V a.c.
6NHG0B 0 6 500 14 21 2 0.26
10NHG0B 10 58 290 2
16NHG0B 16 240 1200 3
20NHG0B 20 490 2500 3.5
25NHG0B 25 1200 5600 3.2
32NHG0B 32 1800 9000 4.8
35NHG0B 35 2400 11,800 4.7
40NHG0B 40 3300 16,500 5
50NHG0B 50 5600 27,800 6.3
63NHG0B 63 6600 26,100 5.6
80NHG0B 80 9800 38,900 7.1
100NHG0B 100 20,600 82,300 7.5
125NHG0B 125 25,000 125,000 11.8
160NHG0B 160 62,000 310,000 12.3
*I
1
is the maximum breaking capacity test at rated voltage according to IEC 60269 requirements
Time in seconds (s)
Time in seconds (s)
Current in Amps (A)
Current in Amps (A)
8
Technical Data 10164
Effective September 2015
Bussmann series
500 Volts gG/gL NH Fuse links
EATON www.eaton.com
Time-current curves - NH Size 01
TIME (Seconds)
CURRENT (Amperes)
68422648 24
10
100 1000
2
6
4
0.1
0.01
1
6
4
2
6
2
4
10
100
6
4
2
6
4
2
6
4
2
1 000
10 000
32
35
40
50
63
80
100
125
160
16
10
20
25
864
6
Technical data - NH size 01
Part numbers
with metal
gripping lugs
Part numbers
with insulated
metal gripping
lugs
Fuse link
size
Rated
current
(Amps)
Rated
voltage
(V a.c.)
I
2
t (Amps
2
Seconds)
Watts loss
Net weight
per fuse
(kg)
Minimum
pre-arcing
*I
1
120kA
at 500 V a.c.
6NHG01B 6NHG01BI 01 6 500 14 21 2 0.27
10NHG01B 10NHG01BI 10 58 290 2
16NHG01B 16NHG01BI 16 240 1200 3
20NHG01B 20NHG01BI 20 490 2500 3.4
25NHG01B 25NHG01BI 25 1200 5600 5
32NHG01B 32NHG01BI 32 1800 9000 4.8
35NHG01B 35NHG01BI 35 2400 11,800 4.6
40NHG01B 40NHG01BI 40 3300 16,500 5
50NHG01B 50NHG01BI 50 5600 27,800 6.3
63NHG01B 63NHG01BI 63 6600 26,100 5.6
80NHG01B 80NHG01BI 80 9800 38,900 7.1
100NHG01B 100NHG01BI 100 20,600 82,300 7.7
125NHG01B 125NHG01BI 125 25,000 125,000 11.8
160NHG01B 160NHG01BI 160 62,000 310,000 12.3
*I
1
is the maximum breaking capacity test at rated voltage according to IEC 60269 requirements
Time in seconds (s)
Time in seconds (s)
Current in Amps (A)
Current in Amps (A)
9
Technical Data 10164
Effective September 2015
Bussmann series
500 Volts gG/gL NH Fuse links
EATON www.eaton.com
Time-current curves - NH Size 1
Technical data - NH size 1
Part numbers
with metal
gripping lugs
Part numbers
with insulated
metal gripping
lugs
Fuse link
size
Rated
current
(Amps)
Rated
voltage
(V a.c.)
I
2
t (Amps
2
Seconds)
Watts loss
Net weight
per fuse
(kg)
Minimum
pre-arcing
*I
1
120kA
at 500 V a.c.
50NHG1B 50NHG1BI** 1 50 500 6350 18,000 6.4 0.39
63NHG1B 63NHG1BI** 63 500 6800 23,000 5.6
80NHG1B 80NHG1BI** 80 500 10,500 31,200 7.7
100NHG1B 100NHG1BI** 100 500 22,000 68,200 8.2
125NHG1B 125NHG1BI** 125 500 29,000 82,000 13
160NHG1B 160NHG1BI** 160 500 62,000 310,000 12.3
200NHG1B 200NHG1BI 200 500 97,000 368,600 15
224NHG1B 224NHG1BI 224 500 124,000 471,200 18
250NHG1B 250NHG1BI 250 500 151,300 574,900 19
315NHG1B 315NHG1BI** 315 440 320,000 750,000 22
355NHG1B 355NHG1BI** 355 440 320,000 750,000 32
*I
1
is the maximum breaking capacity test at rated voltage according to IEC 60269 requirements
** Available upon request
Time in seconds (s)
Time in seconds (s)
Current in Amps (A)
Current in Amps (A)

160NHG01B

Mfr. #:
Manufacturer:
Bussmann / Eaton
Description:
Specialty Fuses 160A 500V GL/GG SIZE 01 DUAL IN
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union