TDA7566 Diagnostics functional description
Doc ID 9801 Rev 6 13/29
Figure 17. SVR and output behavior (case 1: without turn-on diagnostic)
Figure 18. SVR and output pin behavior (case 2: with turn-on diagnostic)
The information related to the outputs status is read and memorized at the end of the
current pulse top. The acquisition time is 100 ms (typ.). No audible noise is generated in the
process. As for short to GND / Vs the fault-detection thresholds remain unchanged from
26 dB to 12 dB gain setting. They are as follows:
Figure 19. Thresholds for short to GND/V
S
Bias (power amp turn-on)
t
Diagnostic Enable
(Permanent)
Permanent diagnostic
acquisition time (100mS Typ)
Permanent Diagnostics data (output)
permitted time
I2CB DATA
Vsvr
Out
FAULT
event
Read Data
Bias (power amp turn-on)
permitted time
Turn-on diagnostic
acquisition time (100mS Typ)
t
Read Data
Permanent diagnostic
acquisition time (100mS Typ)
Permanent Diagnostics data (output)
permitted time
Diagnostic Enable
(Turn-on)
Turn-on Diagnostics data (output)
permitted time
I2CB DATA
Vsvr
Out
Diagnostic Enable
(Permanent)
FAULT
event
D01AU1253
S.C. to GND x S.C. to Vs
0V 1.8V V
S
-1.8V V
S
xNormal Operation
1.2V V
S
-1.2V
Diagnostics functional description TDA7566
14/29 Doc ID 9801 Rev 6
Concerning short across the speaker / open speaker, the threshold varies from 26 dB to
12 dB gain setting, since different loads are expected (either normal speaker's impedance
or high impedance). The values in case of 26 dB gain are as follows:
Figure 20. Thresholds for short across the speaker/open speaker
If the Line-Driver mode (G
v
= 12 dB and Line Driver Mode diagnostic = 1) is selected, the
same thresholds will change as follows:
Figure 21. Thresholds for line-drivers
4.2 Permanent diagnostics
Detectable conventional faults are:
short to GND
short to Vs
short across the speaker
The following additional features are provided:
output offset detection
AC diagnostic
The TDA7566 has 2 operating statuses:
1. Restart mode. The diagnostic is not enabled. Each audio channel operates
independently from each other. If any of the a.m. faults occurs, only the channel(s)
interested is shut down. A check of the output status is made every 1 ms (Figure 22).
Restart takes place when the overload is removed.
2. Diagnostic mode. It is enabled via I
2
C bus and self activates if an output overload (such
to cause the intervention of the short-circuit protection) occurs to the speakers outputs.
Once activated, the diagnostics procedure develops as follows (Figure 23):
To avoid momentary re-circulation spikes from giving erroneous diagnostics, a
check of the output status is made after 1ms: if normal situation (no overloads) is
detected, the diagnostic is not performed and the channel returns back active.
Instead, if an overload is detected during the check after 1 ms, then a diagnostic
cycle having a duration of about 100 ms is started.
After a diagnostic cycle, the audio channel interested by the fault is switched to
Restart mode. The relevant data are stored inside the device and can be read by
the microprocessor. When one cycle has terminated, the next one is activated by
S.C. across Load x Open Load
0V 1.65Ω
45Ω
Infinite
xNormal Operation
0.5Ω
85Ω
AC00566
D02AU1340
S.C. across Load x Open Load
0Ω 7Ω 180Ω infinite
xNormal Operation
2Ω 330Ω
TDA7566 Diagnostics functional description
Doc ID 9801 Rev 6 15/29
an I
2
C reading. This is to ensure continuous diagnostics throughout the car-radio
operating time.
To check the status of the device a sampling system is needed. The timing is
chosen at microprocessor level (over half a second is recommended).
Figure 22. Restart timing without diagnostic enable (Permanent)
each 1 ms time, a sampling of the fault is done
Figure 23. Restart timing with diagnostic enable (Permanent)
4.3 Output DC offset detection
Any DC output offset exceeding ±2 V are signalled out. This inconvenient might occur as a
consequence of initially defective or aged and worn-out input capacitors feeding a DC
component to the inputs, so putting the speakers at risk of overheating.
This diagnostic has to be performed with low-level output AC signal (or V
in
= 0).
The test is run with selectable time duration by microprocessor (from a "start" to a "stop"
command):
START = Last reading operation or setting IB1 - D5 - (OFFSET enable) to 1
STOP = Actual reading operation
Excess offset is signalled out if persistent throughout the assigned testing time. This feature
is disabled if any overloads leading to activation of the short-circuit protection occurs in the
process.
t
1-2mS
1mS 1mS 1mS
1mS
Overcurrent and short
circuit protection intervention
(i.e. short circuit to GND)
Short circuit removed
Out
t
Overcurrent and short
(i.e. short circuit to GND)
Short circuit removed
1mS 100mS 1mS1mS