MG600Q2YS60A

Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
MG600Q2YS60A
Dual IGBTMOD™
Compact IGBT Series Module
600 Amperes/1200 Volts
4 7/05
COLLECTOR CURRENT, I
C
, (AMPERES)
SWITCHING TIME, t
f
, (µs)
FALL TIME VS.
COLLECTOR CURRENT
(TYPICAL)
10
3
10
2
10
1
0 600400200
COLLECTOR CURRENT, I
C
, (AMPERES)
SWITCHING TIME, t
r
, (µs)
RISE TIME VS.
COLLECTOR CURRENT
(TYPICAL)
V
CC
= 600V
V
GE
= ±15V
R
G
= 7.5
T
j
= 25°C
T
j
= 125°C
10
4
10
3
10
2
0 600400200
COLLECTOR CURRENT, I
C
, (AMPERES)
SWITCHING TIME, t
d(off)
, (µs)
TURN-OFF DELAY TIME VS.
COLLECTOR CURRENT
(TYPICAL)
V
CC
= 600V
V
GE
= ±15V
R
G
= 7.5
T
j
= 25°C
T
j
= 125°C
10
4
10
3
10
2
0 600400200
COLLECTOR CURRENT, I
C
, (AMPERES)
SWITCHING TIME, t
d(on)
, (µs)
TURN-ON DELAY TIME VS.
COLLECTOR CURRENT
(TYPICAL)
V
CC
= 600V
V
GE
= ±15V
R
G
= 7.5
T
j
= 25°C
T
j
= 125°C
10
3
10
2
10
1
0 600400200
V
CC
= 600V
V
GE
= ±15V
R
G
= 7.5
T
j
= 25°C
T
j
= 125°C
10
4
10
3
10
2
5 2010 15 5 2010 15
GATE RESISTANCE, R
G
, ()
SWITCHING TIME, t
off
, (µs)
TURN-OFF TIME VS.
GATE RESISTANCE
(TYPICAL)
V
CC
= 600V
V
GE
= ±15V
I
C
= 600A
T
j
= 25°C
T
j
= 125°C
10
4
10
3
10
2
GATE RESISTANCE,
R
G
, ()
SWITCHING TIME, t
on
, (µs)
TURN-ON TIME VS.
GATE RESISTANCE
(TYPICAL)
V
CC
= 600V
V
GE
= ±15V
I
C
= 600A
T
j
= 25°C
T
j
= 125°C
10
4
10
3
10
2
SWITCHING TIME, t
d(off)
, (µs)
TURN-OFF DELAY TIME VS.
GATE RESISTANCE
(TYPICAL)
V
CC
= 600V
V
GE
= ±15V
I
C
= 600A
T
j
= 25°C
T
j
= 125°C
10
4
10
3
10
2
SWITCHING TIME, t
d(on)
, (µs)
TURN-ON DELAY TIME VS.
GATE RESISTANCE
(TYPICAL)
V
CC
= 600V
V
GE
= ±15V
I
C
= 600A
T
j
= 25°C
T
j
= 125°C
10
4
10
3
10
2
SWITCHING TIME, t
f
, (µs)
FALL TIME VS.
GATE RESISTANCE
(TYPICAL)
V
CC
= 600V
V
GE
= ±15V
I
C
= 600A
T
j
= 25°C
T
j
= 125°C
5 2010 15 5 2010 15
GATE RESISTANCE, R
G
, () GATE RESISTANCE, R
G
, ()
5 2010 15
GATE RESISTANCE, R
G
, ()
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
MG600Q2YS60A
Dual IGBTMOD™
Compact IGBT Series Module
600 Amperes/1200 Volts
57/05
10
3
10
2
10
1
0 600400200
COLLECTOR CURRENT, I
C
, (AMPERES)
SWITCHING LOSS, E
off
, (mJ/PULSE)
SWITCHING LOSS (OFF) VS.
COLLECTOR CURRENT
(TYPICAL)
V
CC
= 600V
V
GE
= ±15V
R
G
= 7.5
T
j
= 25°C
T
j
= 125°C
10
1
10
3
10
2
SWITCHING LOSS, E
off
, (mJ/PULSE)
SWITCHING LOSS (OFF) VS.
GATE RESISTANCE
(TYPICAL)
GATE RESISTANCE, R
G
, ()
V
CC
= 600V
V
GE
= ±15V
I
C
= 600A
T
j
= 25°C
T
j
= 125°C
10
3
10
2
10
1
0 600400200
COLLECTOR CURRENT, I
C
, (AMPERES)
SWITCHING LOSS, E
on
, (mJ/PULSE)
SWITCHING LOSS (ON) VS.
COLLECTOR CURRENT
(TYPICAL)
V
CC
= 600V
V
GE
= ±15V
R
G
= 7.5
T
j
= 25°C
T
j
= 125°C
10
1
10
3
10
2
SWITCHING LOSS, E
on
, (mJ/PULSE)
SWITCHING LOSS (ON) VS.
GATE RESISTANCE
(TYPICAL)
GATE RESISTANCE, R
G
, ()
V
CC
= 600V
V
GE
= ±15V
I
C
= 600A
T
j
= 25°C
T
j
= 125°C
10
3
10
2
10
1
0 600400200
FORWARD CURRENT, I
F
, (AMPERES)
REVERSE RECOVERY CURRENT, I
rr
, (AMPERES)
REVERSE RECOVERY CURRENT
(TYPICAL)
V
CC
= 600V
V
GE
= -10V
di/dt = 2000A/µs
T
j
= 25°C
T
j
= 125°C
10
4
10
3
10
2
SWITCHING TIME, t
r
, (µs)
RISE TIME VS.
GATE RESISTANCE
(TYPICAL)
V
CC
= 600V
V
GE
= ±15V
I
C
= 600A
T
j
= 25°C
T
j
= 125°C
5 2010 15
5 2
010 15 5 2010 15
GATE RESISTANCE, R
G
, ()
10
2
10
1
10
0
0 600200 400
FORWARD CURRENT, I
F
, (AMPERES)FORWARD CURRENT, I
F
, (AMPERES)
REVERSE RECOVERY LOSS, E
dsw
, (mJ/PULSE)
REVERSE RECOVERY LOSS VS.
FORWARD CURRENT
(TYPICAL )
10
3
10
2
10
1
0 600200 400
REVERSE RECOVERY TIME, t
rr
, (ns)
REVERSE RECOVERY TIME
(TYPICAL)
COLLECTOR-EMITTER VOLTAGE, V
CE
, (VOLTS)
CAPACITANCE, C
ies
, C
oes
, C
res
, (pF)
10
-2
10
0
10
-1
10
1
10
2
CAPACITANCE VS.
COLLECTOR-EMITTER VOLTAGE
(TYPICAL)
10
5
10
3
10
2
10
4
V
CC
= 600V
V
GE
= -10V
di/dt = 2000A/µs
T
j
= 25°C
T
j
= 125°C
V
CC
= 600V
V
GE
= -10V
di/dt = 2000A/µs
T
j
= 25°C
T
j
= 125°C
C
ies
C
oes
C
res
V
GE
= 0V
f = 1MHz
T
j
= 25°C
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
MG600Q2YS60A
Dual IGBTMOD™
Compact IGBT Series Module
600 Amperes/1200 Volts
6 7/05
0
COLLECTOR-EMITTER VOLTAGE, V
CE
, (VOLTS)
COLLECTOR CURRENT, I
iC
, (AMPERES)
0 200 600400 800 1000 1200 1400
REVERSE BIAS
SAFE OPERATION AREA
(TYPICAL)
10
4
10
0
10
2
10
3
10
1
GATE-EMITTER VOLTAGE, V
GE
, (VOLTS)
GATE CHARGE, Q
G
, (nC)
GATE-EMITTER VOLTAGE VS.
GATE CHARGE
(TYPICAL)
600V
200V
400V
V
CE
= 0V
COLLECTOR-EMITTER VOLTAGE, V
CE
, (VOLTS)
0
GATE CHARGE, Q
G
, (nC)
COLLECTOR-EMITTER VOLTAGE VS.
GATE CHARG
E
(TYPICAL)
0
200
400
600
800
2000
400030001000
I
C
= 400A
R
L
= 1.0
T
j
= 25°C
0
0
4
8
12
16
2000 400030001000
I
C
= 400A
R
L
= 1.0
T
j
= 25°C
V
GE
= ±15V
R
G
= 7.5
T
j
125°C
COLLECTOR-EMITTER VOLTAGE, V
CE
, (VOLTS)
COLLECTOR CURRENT, I
iC
, (AMPERES)
0 400 800 1200 1600
SHORT CIRCUIT
SAFE OPERATING AREA
(TYPICAL)
5000
3000
1000
4000
2000
PULSE WIDTH, t
w
, (s)
0
GATE RESISTANCE R
G
, (
)
SHORT CIRCUIT
PULSE WIDTH VS. GATE RESISTANCE
(TYPICAL)
0
5
10
15
20
5 10 2
015
TIME, (s)
TRANSIENT IMPEDANCE, Rth
(j-c)
10
-3
10
-2
10
-1
10
0
10
1
TRANSIENT THERMAL
IMPEDANCE CHARACTERISTICS
(IGBT)
10
0
10
-2
10
-4
10
-3
10
-1
V
CC
= 600V
V
GE
= ±15V
R
G
= 7.5
T
j
125°C
V
CC
= 950V
V
GE
= ±15V
T
j
= 25°C
SINGLE PULSE
STANDARD VALUE =
R
th(j-c)
D = 0.05C/W
T
C
= 25°C
SINGLE PULSE
STANDARD VALUE =
R
th(j-c)
Q = 0.02C/W
T
C
= 25°C
TIME, (s)
TRANSIENT IMPEDANCE, Rth
(j-c)
10
-3
10
-2
10
-1
10
0
10
1
TRANSIENT THERMAL
IMPEDANCE CHARACTERISTICS
(FWDi)
10
0
10
-2
10
-4
10
-3
10
-1

MG600Q2YS60A

Mfr. #:
Manufacturer:
Description:
IGBT MOD CMPCT 1200V 600A
Lifecycle: