M48Z128, M48Z128Y DC and AC parameters
Doc ID 2426 Rev 6 13/20
4 DC and AC parameters
This section summarizes the operating and measurement conditions, as well as the DC and
AC characteristics of the device. The parameters in the following DC and AC characteristic
tables are derived from tests performed under the measurement conditions listed in the
relevant tables. Designers should check that the operating conditions in their projects match
the measurement conditions when using the quoted parameters.
Table 6. Operating and AC measurement conditions
Note: Output Hi-Z is defined as the point where data is no longer driven.
Figure 9. AC measurement load circuit
Table 7. Capacitance
Parameter M48Z128/Y Unit
Supply voltage (V
CC
) 4.75 to 5.5 V or 4.5 to 5.5 V
Ambient operating temperature (T
A
)0 to 70°C
Load capacitance (C
L
) 100 pF
Input rise and fall times ≤ 5ns
Input pulse voltages 0 to 3 V
Input and output timing ref. voltages 1.5 V
Symbol Parameter
(1)(2)
1. Effective capacitance measured with power supply at 5 V; sampled only, not 100% tested.
2. At 25 °C, f = 1 MHz.
Min Max Unit
C
IN
Input capacitance - 10 pF
C
IO
(3)
3. Outputs deselected.
Input / output capacitance - 10 pF
AI03630
C
L
= 100pF
C
L
includes JIG capacitance
650Ω
DEVICE
UNDER
TEST
1.75V
Obsolete Product(s) - Obsolete Product(s)