I
NTEGRATED
C
IRCUITS
D
IVISION
8 www.ixysic.com R07
CPC7583
1.6.4 TEST
OUT
Switches, SW5 and SW6
Parameter Test Conditions Symbol Minimum Typical Maximum Unit
Off-state leakage current
+25° C
V
SW
(differential) = -320 V to gnd
V
SW
(differential) = +260 V to -60 V
I
SW
-
0.1
1 A+85° C
V
SW
(differential) = -330 V to gnd
V
SW
(differential) = +260 V to -60 V
0.3
-40° C
V
SW
(differential) = -310 V to gnd
V
SW
(differential) = +250 V to -60 V
0.1
R
ON
+25° C
I
SW
(on) = ±10 mA, ±40 mA R
ON
-
35 -
+85° C 50 70
-40° C 26 -
DC current limit
+25° C
V
SW
(on) = ±10 V
I
SW
- 140 -
mA+85° C 80 100 -
-40° C - 210 250
Dynamic current limit
(t 0.5 s)
Break switches in on state, ringing
switches off, apply ±1 kV at
10x1000 s pulse, with appropriate
secondary protection in place.
-2.5- A
Logic input to switch output isolation
+25° C
V
SW
(T
TESTout
, T
LINE
, R
TESTout
, R
LINE
)
= ±320 V, logic inputs = gnd
I
SW
-0.11A
+85° C
V
SW
(T
TESTout
, T
LINE
, R
TESTout
, R
LINE
)
= ±330 V, logic inputs = gnd
I
SW
-0.31A
-40° C
V
SW
(T
TESTout
, T
LINE
, R
TESTout
, R
LINE
)
= ±310 V, logic inputs = gnd
I
SW
-0.11A
dv/dt sensitivity - - 200 - V/s