1) Operating temperatures above +85 °C can cause a change in color of the coating material, which has no impact on the reliability of the
components.
Features
EMI/ RFI noise suppression and transient overvoltage protection integrated in
a single component
Suppression of transients, caused by sudden interruption of currents
Protection against electrical transients in automotive battery lines
(acc. to ISO 7637-2 and ISO 16750-2)
High capacitance (up to 4.7 µF)
Low clamping voltage
RoHS-compatible
Suitable for lead-free soldering
PSpice simulation models available
Applications
RFI noise suppression and transient overvoltage protection on DC lines of
small motors, windscreen wipers, window lifters, mirrors, central locking,
memory seat, sunroof
Design
Combination of multilayer RF filter capacitor and multilayer varistor
Coating: flame-retardant to UL 94 V0, epoxy resin
Terminals: tinned iron wire, RoHS-compatible
V/I characteristics and derating curves
V/I and derating curves are attached to the data sheet. The curves are sorted
by V
RMS
and then by case size, which is included in the type designation.
General technical data
Maximum RMS operating voltage V
RMS,max
14 ... 35 V
Maximum DC operating voltage V
DC,max
16 ... 45 V
Maximum surge current (8/20 µs) I
surge,max
100 ... 1200 A
Maximum load dump energy (10 pulses) W
LD
1.5 ... 12 J
Maximum jump-start voltage (5 min) V
jump
24.5 ... 45 V
Maximum clamping voltage (8/20 µs) V
clamp,max
38 ... 90 V
Nominal capacitance (1 kHz, 0.5 V) C
nom
220 ... 4700 nF
Insulation resistance R
ins
≥ 10 MΩ
Response time t
resp
< 25 ns
Operating temperature
1)
T
op
55/+125 °C
Storage temperature LCT/UCT 55/+150 °C
Leaded transient voltage/RFI suppressors (SHCVs)
SHCV series
Page 3 of 22Please read Cautions and warnings and