M41T80 DC and AC parameters
Doc ID 9074 Rev 5 19/27
5 DC and AC parameters
This section summarizes the operating and measurement conditions, as well as the DC and
AC characteristics of the device. The parameters in the following DC and AC Characteristic
tables are derived from tests performed under the measurement conditions listed in the
relevant tables. Designers should check that the operating conditions in their projects match
the measurement conditions when using the quoted parameters.
Figure 12. AC measurement I/O waveform
Table 8. Operating and AC measurement conditions
(1)
1. Output Hi-Z is defined as the point where data is no longer driven.
Parameter M41T80
Supply voltage (V
CC
) 2.0 to 5.5 V
Ambient operating temperature (T
A
) –40 to 85 °C
Load capacitance (C
L
)100 pF
Input rise and fall times 50 ns
Input pulse voltages 0.2V
CC
to 0.8V
CC
Input and output timing ref. voltages 0.3V
CC
to 0.7V
CC
Table 9. Capacitance
Symbol Parameter
(1)(2)
1. Effective capacitance measured with power supply at 5 V; sampled only, not 100% tested.
2. At 25 °C, f = 1 MHz.
Min Max Unit
C
IN
Input capacitance 7 pF
C
OUT
(3)
3. Outputs deselected.
Output capacitance 10 pF
t
LP
Low-pass filter input time constant (SDA and SCL) 50 ns
AI02568
0.8V
CC
0.2V
CC
0.7V
CC
0.3V
CC
DC and AC parameters M41T80
20/27 Doc ID 9074 Rev 5
Table 10. DC characteristics
Symbol Parameter Test condition
(1)
1. Valid for ambient operating temperature: T
A
= –40 to 85 °C; V
CC
= 2.0 to 5.5 V (except where noted).
Min Typ Max Unit
I
LI
Input leakage current 0 V V
IN
V
CC
±1 µA
I
LO
Output leakage current 0 V V
OUT
V
CC
±1 µA
I
CC1
Supply current Switch freq (SCL) = 400 kHz
3.0 V 30 µA
5.5 V 200 µA
I
CC2
(2)
2. At 25 °C.
Supply current
(standby)
All inputs = V
CC
– 0.2 V
Switch freq (SCL) = 0 Hz
32KE = 1
or
SQWE = 1
3.0 V 1.8 3.0 µA
5.5 V 35 µA
32KE = 0
and
SQWE = 0
3.0 V 1.5 2.4 µA
5.5 V 31 µA
V
IL
Input low voltage –0.3 0.3V
CC
V
V
IH
Input high voltage 0.7V
CC
V
CC
+ 0.3 V
V
OL
Output low voltage I
OL
= 3.0 mA 0.4 V
Output low voltage
(open drain)
(3)
3. For IRQ/FT/OUT, RST, and 32 KHz pins (open drain)
I
OL
= 10 mA 0.4 V
Pull-up supply voltage
(open drain)
IRQ
/OUT/SQW, F
32K
, SCL, SDA 5.5 V
Table 11. Crystal electrical characteristics
Sym Parameter
(1)
(2)
1. Externally supplied if using the SO8 package. STMicroelectronics recommends the KDS DT-38: 1TA/1TC252E127, Tuning
Fork Type (thru-hole) or the DMX-26S: 1TJS125FH2A212, (SMD) quartz crystal for industrial temperature operations.
2. Load capacitors are integrated within the M41T80. Circuit board layout considerations for the 32.768 kHz crystal of
minimum trace lengths and isolation from RF generating signals should be taken into account.
Min Typ Max Units
f
O
Resonant frequency 32.768 kHz
R
S
Series resistance 60 kΩ
C
L
Load capacitance 12.5 pF
M41T80 Package mechanical data
Doc ID 9074 Rev 5 21/27
6 Package mechanical data
In order to meet environmental requirements, ST offers these devices in different grades of
ECOPACK
®
packages, depending on their level of environmental compliance. ECOPACK
®
specifications, grade definitions and product status are available at: www.st.com.
ECOPACK
®
is an ST trademark.

M41T80M6F

Mfr. #:
Manufacturer:
STMicroelectronics
Description:
Real Time Clock Serial 160 (20x8)
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet