OPTEK reserves the right to make changes at any time in order to improve design and to supply the best product possible.
Hallogic Hall-effect Sensors
OH090U, OH180U, OH360U
OHN3000 Series, OHS3000 Series
OHN3100 Series, OHS3100 Series
OPTEK Technology Inc. — 1645 Wallace Drive, Carrollton, Texas 75006
Phone: (972) 323-2200 or (800) 341-4747 FAX: (972) 323-2396 sensors@optekinc.com www.optekinc.com
Issue B.1 01/09
Page 10 of 10
Rise & Fall Time vs Temperature
0
50
100
150
200
250
300
350
-40°C 0°C 40°C 80°C 120°C 150°C
Temperature (°C)
Typical Time (ns)
Rise Time
Fall Time
Saturation Voltage vs Temperature
0.10
0.15
0.20
0.25
0.30
0.35
0.40
-40°C 0°C 40°C 80°C 120°C 150°C
Temperature (°C)
Typical Saturation Voltage (V)
R
L
= 820
ohms
Icc vs Temperature
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
-40°C 0°C 40°C 80°C 120°C 150°C
Temperature (°C)
Typical Icc (mA)
Icc ON (mA)
Icc OFF (mA)
U.U.T.
820 Ohm
20 pf
3
2
1
Vcc
Output
Ground
V
OL
OH
V
10%
90%
TrTf
90%
10%
B
OP
RP
B
Magnetic Field

OHN3131U

Mfr. #:
Manufacturer:
Optek / TT Electronics
Description:
Board Mount Hall Effect / Magnetic Sensors Hall Effect Sensor
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet