Data Sheet ADuM7640/ADuM7641/ADuM7642/ADuM7643
Rev. 0 | Page 9 of 20
PACKAGE CHARACTERISTICS
Table 13.
Parameter Symbol Min Typ Max Unit Test Conditions/Comments
Resistance (Input to Output)
1
I-O
Capacitance (Input to Output)
1
C
I-O
2 pF f = 1 MHz
Input Capacitance
2
C
I
4.0 pF
IC Junction-to-Ambient Thermal Resistance θ
JA
76 °C/W
Thermocouple located at
center of package underside
1
The device is considered a 2-terminal device: Pin 1 through Pin 10 are shorted together, and Pin 11 through Pin 20 are shorted together.
2
Input capacitance is from any input data pin to ground.
REGULATORY INFORMATION
The ADuM7640/ADuM7641/ADuM7642/ADuM7643 are approved by the organizations listed in Table 14. See Table 18 and the
Insulation Lifetime section for recommended maximum working voltages for specific cross-isolation waveforms and insulation levels.
Table 14.
UL (Pending)
Recognized Under UL 1577 Component Recognition Program
1
Single Protection,1000 V rms Isolation Voltage
File E274400
1
In accordance with UL 1577, each ADuM7640/ADuM7641/ADuM7642/ADuM7643 is proof tested by applying an insulation test voltage ≥ 1200 V rms for 1 sec (current
leakage detection limit = 5 µA).
INSULATION AND SAFETY RELATED SPECIFICATIONS
Table 15.
Parameter Symbol Value Unit Test Conditions/Comments
Rated Dielectric Insulation Voltage 1000 V rms 1 minute duration
Minimum External Air Gap (Clearance) L(I01) 3.8 mm min
Measured from input terminals to output
terminals, shortest distance through air
Minimum External Tracking (Creepage) L(I02) 2.8 mm min
Measured from input terminals to output
terminals, shortest distance path along body
Minimum Internal Gap (Internal Clearance) 2.6 μm min Insulation distance through insulation
Tracking Resistance (Comparative Tracking Index) CTI >400 V DIN IEC 112/VDE 0303 Part 1
Isolation Group II Material Group (DIN VDE 0110, 1/89, Table 1)
CASE TEMPERATURE (°C)
SAFETY-LIMITING CURRENT (mA)
0
0
350
300
250
200
150
100
50
50 100 150 200
10448-005
Figure 5. Thermal Derating Curve, Dependence of Safety-Limiting Values on
Case Temperature per DIN V VDE V 0884-10
RECOMMENDED OPERATING CONDITIONS
Table 16.
Operating Temperature T
A
−40 +105 °C
1
DD1
DD2
Input Signal Rise and Fall
Times
1.0 ms
1
All voltages are relative to their respective grounds. See the DC Correctness
section for information about immunity to external magnetic fields.