Electrical specifications VND830AEP-E
8/26 Doc ID 11038 Rev 4
Note: To ensure long term reliability under heavy overload or short circuit conditions, protection
and related diagnostic signals must be used together with a proper software strategy. If the
device is subjected to abnormal conditions, this software must limit the duration and number
of activation cycles.
Table 6. Protections
Symbol Parameter Test conditions Min. Typ. Max. Unit
I
lim
Current limitation
V
CC
= 13V
5.5V < V
CC
< 36V
61015
15
A
A
T
TSD
Shutdown temperature 150 175 200 °C
T
R
Reset temperature 135 °C
T
hyst
Thermal hysteresis 7 15 °C
V
demag
Turn-off output clamp voltage
I
OUT
= 2A; V
IN
= 0V;
L = 6mH
V
CC
-
41
V
CC
-
48
V
CC
-
55
V
V
ON
Output voltage drop limitation I
OUT
= 10mA 50 mV
Table 7. V
CC
- output diode
Symbol Parameter Test conditions Min. Typ. Max. Unit
V
F
Forward on voltage - I
OUT
= 1.3A; T
j
= 150°C 0.6 V
Table 8. Switching (V
CC
= 13V; T
j
= 25°C)
Symbol Parameter Test conditions Min. Typ. Max. Unit
t
d(on)
Turn-on delay time
R
L
= 6.5Ω from V
IN
rising
edge to V
OUT
= 1.3V (see
Figure 5)
30 µs
t
d(off)
Turn-off delay time
R
L
= 6.5Ω from V
IN
falling
edge to V
OUT
= 11.7V
(see Figure 5)
30 µs
dV
OUT
/dt
(on)
Turn-on voltage slope
R
L
= 6.5Ω from V
OUT
= 1.3V to
V
OUT
= 10.4V (see Figure 5)
See
Figure 10
V/µs
dV
OUT
/dt
(off)
Turn-off voltage slope
R
L
= 6.5Ω from V
OUT
= 11.7V
to V
OUT
= 1.3V (see Figure 5)
See
Figure 12
V/µs
Table 9. Logic inputs
Symbol Parameter Test conditions Min. Typ. Max. Unit
V
IL
Input low level 1.25 V
I
IL
Low level input current V
IN
= 1.25V 1 µA
V
IH
Input high level 3.25 V
I
IH
High level input current V
IN
= 3.25V 10 µA