4
MY MY
Rated
Rated current (mA)
Pick-up Dropout Maximum Power consumption
voltage Set coil
Reset coil
Coil resistance () voltage voltage voltage (VA, W)
(V)
50 Hz 60 Hz 50/60 Hz Set coil Reset coil (% of rated voltage) Set coil Reset coil
6 146 142 68 13 32 80% max. 80% max. 110% max. Approx. Approx.
12 57 56 39 72 130
0.60 to 0.90 0.20 to 0.50
24 27.40 26.40 18.60 320 550
50 14 13.40 3.50 1,400 3,000
120 15.80 5.60 3.50 8,300 3,000
Latching – AC
Coil inductance
Coil (ref. value) (H) Pick-up Dropout Maximum Power
Rated
Rated current (mA)
resistance
Armature Armature
voltage voltage voltage consumption
voltage (V)
50 Hz 60 Hz
()
OFF ON (% of rated voltage)
(VA, W)
6 214.10 183 12.20 0.04 0.08 80% max. 30% min. 110% max. Approx.
12 106.50 91 46 0.17 0.33
1.00 to 1.20
24 53.80 46 180 0.69 1.30
50 25.70 22 788 3.22 5.66
100/110 11.70/12.90 10/11 3,750 14.54 24.60 Approx.
110/120 9.90/10.80 8.40/9.20 4,430 19.20 32.10
0.90 to 1.10
200/220 6.20/6.80 5.30/5.80 12,950 54.75 94.07
220/240 4.80/5.30 4.20/4.60 18,790 83.50 136.40
COIL DATA
Non-latching – AC
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with tolerances of +15%, -20% for
AC rated current, and ±15% for DC rated coil resistance.
2. The AC coil resistance and inductance are reference values at 60 Hz.
3. The performance characteristics are measured at a coil temperature of 23°C (73°F).
4. Because the coil is designed for low power consumption, connect a bleeder (if necessary after confirming the leakage
current), when the coil is driven by an SCR.
5. For AC type latching coils, the rated current values are half-wave rectified current values measured with a DC ammeter.
Coil inductance
Coil (ref. value) (H) Pick-up Dropout Maximum Power
Rated resistance
Armature Armature
voltage voltage voltage consumption
voltage (V) Rated current (mA) ()
OFF ON (% of rated voltage)
(VA, W)
6 150 40 0.17 0.33 80% max. 10% min. 110% max. Approx.
12 75 160 0.73 1.37
0.90
24 36.90 650 3.20 5.72
48 18.50 2,600 10.60 21.00
100/110 9.10/10 11,000 45.60 86.20
Non-latching – DC
Rated
Rated current (mA)
Pick-up Dropout Maximum Power consumption
voltage Set coil Reset coil Coil resistance () voltage voltage voltage (VA, W)
(V)
50/60 Hz 50/60 Hz Set coil Reset coil (% of rated voltage) Set coil Reset coil
6 230 100 26 60 80% max. 80% max. 110% max. Approx. Approx.
12 110 50 110 235
1.30 0.06
24 52 25 470 940
Latching – DC
5
MY MY
Contact resistance 50 m max.
Operate time 20 ms max.
Release time 20 ms max.
Operating frequency Mechanically 18,000 operations/hour
Under rated load 1,800 operations/hour
Insulation resistance 100 M min. (at 500 VDC)
Dielectric strength Single contact type Unsealed: 2,000 VAC, 50/60 Hz for 1 minute
1,000 VAC, 50/60 Hz for 1 minute between contacts of same polarity
Sealed: 1,500 VAC, 50/60 Hz for 1 minute
1,000 VAC, 50/60 Hz for 1 minute between contacts of same polarity
Hermetically sealed: 1,000 VAC, 50/60 Hz for 1 minute
700 VAC, 50/60 Hz for 1 minute between contacts of same polarity
Bifurcated contact type 1,500 VAC, 50/60 Hz for 1 minute
1,000 VAC, 50/60 Hz for 1 minute between non-continuous contacts
Vibration Mechanical durability 10 to 55 Hz, 1.00 mm (0.04 in) double amplitude
Malfunction durability 10 to 55 Hz, 1.00 mm (0.04 in) double amplitude
Shock Mechanical durability 1,000 m/s
2
(approx. 100 G)
Malfunction durability 200 m/s
2
(approx. 20 G)
Ambient temperature Operating Unsealed: -55° to 70°C (-67° to 158°F)
Sealed: -55° to 60°C (-67° to 140°F)
Hermetically sealed: 25° to 60°C (77° to 140°F)
Humidity 35% to 85% RH
Service Life Mechanically Single contact type:
AC: 50 million operations min. (at operating frequency of 18,000 operations/hour)
DC: 100 million operations min. (at operating frequency of 18,000 operations/hour)
Mechanically Bifurcated contact type:
AC: 50 million operations min.
DC: 20 million operations min. (5 million operations for the sealed/hermetically
sealed types) (at operating frequency of 1,800 operations/hour)
Electrically See “Characteristic Data”
Weight Sealed/unsealed: Approx. 35 g (1.23 oz)
Hermetically sealed: Approx. 50 g (1.76 oz)
CHARACTERISTICS
Non-latching
Note: Data shown are of initial value.
Contact resistance 50 m max.
Operate time AC: 30 ms max.; DC: 15 ms max.
Release time AC: 30 ms max.; DC: 15 ms max.
Operating frequency Mechanically 18,000 operations/hour
Under rated load 1,800 operations/hour
Insulation resistance 100 M min. (at 500 VDC)
Dielectric strength 1,500 VAC, 50/60 Hz for 1 minute
1,000 VAC, 50/60 Hz for 1 minute between contacts of same polarity, and between
set and reset coils
Vibration Mechanical durability 10 to 55 Hz, 1.00 mm (0.04 in) double amplitude
Malfunction durability 10 to 55 Hz, 1.00 mm (0.04 in) double amplitude
Shock Mechanical durability 1,000 m/s
2
(approx. 100 G)
Malfunction durability 200 m/s
2
(approx. 20 G)
Ambient temperature Operating -55° to 70°C (-67° to 158°F)
Humidity 45% to 85% RH
Service Life Mechanically 100 million operations min. (at operating frequency of 18,000 operations/hour)
Electrically See “Characteristic Data”
Weight Approx. 30 g (1.06 oz)
Latching
6
MY MY
CHARACTERISTIC DATA
Maximum switching capacity – Non-latching
MY2, MY3 MY4 MY4(Z)H MYQ4(Z)H
Electrical service life
MY2, MY3 (Resistive load) MY2, MY3 (Inductive load) MY4 (Resistive load) MY4 (Inductive load)
Rated operating current (A)
Rated operating current (A)
Rated operating current (A)
Rated operating current (A)
Rated operating voltage (V)
Rated operating voltage (V) Rated operating voltage (V)
Rated operating voltage (V)
Service life (operations x 10
6
)
Service life (operations x 10
6
)
Service life (operations x 10
6
)
Service life (operations x 10
6
)
Rated operating current (A)
Rated operating current (A) Rated operating current (A)
Rated operating current (A)
MY4H MY4Z (Resistive load) MY4Z (Inductive load) MYQ4
Service life (operations x 10
6
)
Service life (operations x 10
6
)
Service life (operations x 10
6
)
Service life (operations x 10
6
)
Rated operating current (A)
Rated operating current (A) Rated operating current (A)
Rated operating current (A)
MY2-Y(Resistive load) MY2-Y (Inductive load)
Service life (operations x 10
6
)
Service life (operations x 10
6
)
Rated operating current (A)
Rated operating current (A)

MYQ4-02-DC24

Mfr. #:
Manufacturer:
Omron Automation and Safety
Description:
General Purpose Relays RELAY
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union