Nexperia
74LVC2G66
Bilateral switch
74LVC2G66 All information provided in this document is subject to legal disclaimers. © Nexperia B.V. 2017. All rights reserved.
Product data sheet Rev. 10 — 13 April 2017
13 / 27
V
EXT
V
CC
V
I
V
O
001aae235
DUT
C
L
R
T
R
L
R
L
PULSE
GENERATOR
V
M
V
M
t
W
t
W
10 %
90 %
0 V
V
I
V
I
negative
pulse
positive
pulse
0 V
V
M
V
M
90 %
10 %
t
f
t
r
t
r
t
f
Test data is given in Table 11.
Definitions test circuit:
R
T
= Termination resistance should be equal to output impedance Z
o
of the pulse generator.
C
L
= Load capacitance including jig and probe capacitance.
R
L
= Load resistance.
V
EXT
= External voltage for measuring switching times.
Figure 19. Test circuit for measuring switching times
Table 11. Test data
Supply voltage Input Load V
EXT
V
CC
V
I
t
r
, t
f
C
L
R
L
t
PLH,
t
PHL
t
PZH,
t
PHZ
t
PZL,
t
PLZ
1.65 V to 1.95 V V
CC
≤ 2.0 ns 30 pF 1 kΩ open GND 2 × V
CC
2.3 V to 2.7 V V
CC
≤ 2.0 ns 30 pF 500 Ω open GND 2 × V
CC
2.7 V 2.7 V ≤ 2.5 ns 50 pF 500 Ω open GND 6 V
3.0 V to 3.6 V 2.7 V ≤ 2.5 ns 50 pF 500 Ω open GND 6 V
4.5 V to 5.5 V V
CC
≤ 2.5 ns 50 pF 500 Ω open GND 2 × V
CC