CB5012-000

© 2008 - 2014 Tyco Electronics Corporation. All rights reserved
If this document is printed it becomes uncontrolled. Check for the latest revision.
TE Connectivity
305 Constitution Drive
Menlo Park, CA 94025 USA
Raychem
Tubing
Specification:
This Issue:
Date:
Replaces:
RW-2017
Issue 8
November 18, 2014
Issue 7
Raychem BSTS/BSTS-FR Tubing
General Purpose Polyolefin Heat-Shrinkable
1. SCOPE
This specification covers requirements for two types of electrically insulating, extruded tubing whose
diameter will reduce to a predetermined size upon the application of heat in excess of 120ºC.
BSTS
BSTS is not flame-retardant. The standard color shall be black, but also available in white, red or clear.
BSTS-FR
BSTS-FR is flame-retardant. The standard color shall be black, but also available in white or red.
2. REQUIREMENTS
2.1 Composition and Appearance
The tubing shall be fabricated from thermally stabilized, modified polyolefin and shall be irradiation
crosslinked. It shall be homogeneous and essentially free from flaws, defects, pinholes, bubbles, seams,
cracks and inclusions.
3. PROPERTIES
The tubing shall meet the requirements of Tables 1 and 2.
4. QUALITY ASSURANCE PROVISIONS
4.1 Classification of Tests
4.1.1 Qualification Tests
Qualification tests are those performed on tubing submitted for qualification as a satisfactory product and
shall consist of all tests listed in this specification.
4.1.2 Production Routine
Production routine tests shall be carried out on every batch, unless otherwise specified and shall consist of
the following: dimensions, longitudinal change, tensile strength, ultimate elongation, heat shock, low
temperature flexibility and flammability. Flammability is not applicable to BSTS.
5. SAMPLING INSTRUCTIONS
5.1 Qualification Test Samples
Qualification test samples shall consist of 45 m (150 feet) of tubing. Qualification of one size from 13 to
17 qualifies all sizes. The color shall be black or clear (BSTS only) unless otherwise specified.
5.2 Production Routine Test Samples
Production routine test samples shall consist of a sufficient length to perform the tests listed in 4.1.2.
selected at random from each batch. A batch shall consist of all tubing of the same size, from the same
production run and offered for inspection at the same time. Physical property tests performed at this time
qualify subsequent tubing lots produced from the same compound batch.
6. TEST PROCEDURES
Unless otherwise specified the tubing shall be recovered in a forced air circulation oven for 10 minutes at
150 2C.
Page 2 SPECIFICATION RW-2017 ISSUE 8
© 2008 - 2014 Tyco Electronics Corporation. All rights reserved
If this document is printed it becomes uncontrolled. Check the latest revision.
6.1 Dimensions and Longitudinal Change
The test method shall be as specified in ASTM D 2671.
The length and inside diameter of three 250 mm (10 inch) long specimens of expanded tubing shall be
measured. The specimens shall be recovered and the length and inside diameter of each shall be measured.
The longitudinal change shall be expressed as a percentage of the original length. The minimum and
maximum recovered wall thicknesses shall be determined.
6.2 Tensile Strength and Ultimate Elongation
The test method shall be as specified in ASTM D 638.
For tubing of recovered inside diameter greater than 6.0 mm (0.236 inch), five Type IV dumbbell
specimens shall be tested. For tubing of recovered inside diameter less than or equal to 6.0 mm
(0.236 inch), five specimens 150 mm (6 inches) long shall be tested. Rate of jaw separation shall be
500 10 mm (20 0.5 inches) per minute. The test shall be carried out at a temperature of 23 2C.
7. PREPARATION FOR DELIVERY
7.1 Form
The tubing shall be supplied in cut lengths unless otherwise specified.
7.2 Packaging
Packaging shall be in accordance with good commercial practice.
7.3 Marking
Each container of tubing shall be legibly marked with the size, quantity, manufacturer's identification and
batch number.
8. RELATED DOCUMENTS
SAE-AMS-1424 De-icing Fluid
SAE-AMS-DTL-23053 Insulation Tubing, Electrical, Heat Shrinkable, General Specification
MIL-STD-104 Limits for Electrical Insulating Color
MIL-H-5606 Hydraulic Fluid, Petroleum Base, Aircraft, Missile and Ordinance
MIL-PRF-7808 Lubricating Oil
MIL-L-23699 Lubricating Oil
MIL-DTL-83133 Turbine Fuel, Aviation, Grade JP-8
A-A-694 5% NaCl
ASTM D 570 Standard Test Method for Water Absorption
ASTM D 638 Standard Test Methods for Tensile Properties of Plastic
ASTM D 792 Standard Test Methods for Specific Gravity (Relative Density) and
Density of Plastics by Displacement
ASTM D 876 Standard Test Methods for Non Rigid Vinyl Chloride Polymer Tubing Used for
Electrical Insulation
ASTM D 882 Standard Test Methods for Tensile Properties of Thin Plastic Sheeting
ASTM D 2671 Standard Methods of Testing Heat-Shrinkable Tubing for Electrical Use
ISO 846 Method B Plastics – Evaluation of the Action of Microorganisms
© 2008 - 2014 Tyco Electronics Corporation. All rights reserved
If this document is printed it becomes uncontrolled. Check the latest revision.
TABLE 1
TUBING DIMENSIONS for BSTS and BSTS-FR
Internal Diameter, mm (inch) Wall Thickness Nom., mm (inch)
Size Minimum Expanded D Maximum Recovered
D
Recovered W
-03 7.62 (0.300) 2.54 (0.100) 1.78 (0.070)
-04 10.16 (0.400) 3.81 (0.150) 1.78 (0.070)
-07 19.05 (0.750) 5.59 (0.220) 2.54 (0.100)
-11 27.94 (1.100) 9.53 (0.375) 3.05 (0.120)
-13 33.02 (1.300) 9.65 (0.380) 3.05 (0.120)
-15 38.10 (1.500) 12.70 (0.500) 3.56 (0.140)
-17 43.18 (1.700) 12.70 (0.500) 3.56 (0.140)
-20 50.80 (2.000) 19.05 (0.750) 4.06 (0.160)
-27 68.58 (2.700) 22.86 (0.900) 4.06 (0.160)
-30 76.20 (3.000) 31.75 (1.250) 4.06 (0.160)
-35 88.90 (3.500) 31.75 (1.250) 4.06 (0.160)
-40 101.60 (4.000) 44.45 (1.750) 4.06 (0.160)
-45 114.30 (4.500) 44.45 (1.750) 4.06 (0.160)

CB5012-000