CB5012-000

Page 4 SPECIFICATION RW-2017 ISSUE 8
© 2008 - 2014 Tyco Electronics Corporation. All rights reserved
If this document is printed it becomes uncontrolled. Check the latest revision.
TABLE 2
REQUIREMENTS
PROPERTY UNIT BSTS BSTS -FR TEST METHOD
PHYSICAL
Dimensions
mm
(inch)
In accordance with
Table 1
In accordance with
Table 1
Section 6.1
ASTM D 2671
Longitudinal Change percent +1, - 10 +1, -10 Section 6.1
ASTM D 2671
Tensile Strength MPa (psi) 8.4 (1,200) minimum 8.4 (1,200) minimum Section 6.2
ASTM D 638
Ultimate Elongation percent 300 minimum 200 minimum Section 6.2
ASTM D 638
2% Secant Modulus (Expanded) MPa (psi) N/A 172.4 (25,000) maximum ASTM D 882
Specific Gravity 1.1 maximum 1.5 maximum ASTM D 792
Low Temperature Flexibility
4 hours at -55 2C
No cracking No cracking SAE-AMS-DTL-23053
Heat Shock
4 hours at 225 3C
No dripping, flowing
or cracking
No dripping, flowing
or cracking
SAE-AMS-DTL-23053
Heat Resistance
168 hrs at 175 2C
Followed by tests for:
Tensile Strength
Ultimate Elongation
MPa (psi)
percent
7.0 (1,000) minimum
100 minimum
7.0 (1,000) minimum
100 minimum
ASTM D 638
ASTM D 638
ELECTRICAL
Dielectric Strength
kV/mm
(V/mil)
7.9 (200) minimum
7.9 (200) minimum
ASTM D 2671
*Note 1
Volume Resistivity ohm-cm 10
13
minimum 10
13
minimum ASTM D 876
CHEMICAL
Copper Mirror Corrosion
16 hours at 120 ± 2ºC
No removal of copper
No removal of copper
SAE-AMS-DTL-23053
Copper Contact Corrosion
16 hours at 120 2C
No pitting or
blackening of copper
No pitting or
blackening of copper
SAE-AMS-DTL-23053
Flammability seconds N/A 60 maximum SAE-AMS-DTL-23053
(ASTM D 2671
Procedure C)
Water Absorption
24 hours at 23 2C
percent 0.5 maximum 0.5 maximum ASTM D 570
Fungus Resistance
Followed by tests for:
Tensile Strength
Ultimate Elongation
Dielectric Strength
MPa (psi)
percent
kV/mm
(V/mil)
8.4 (1,200) minimum
300 minimum
7.9 (200) minimum
8.4 (1,200) minimum
200 minimum
7.9 (200) minimum
ISO 846 Method B
ASTM D 638
ASTM D 638
ASTM D 2671
Fluid Resistance
24 hours at 23 2C
JP-8 Fuel (MIL-DTL-83133)
Hydraulic Fluid (MIL-H-5606)
De-icing Fluid (SAE-AMS-
1424
)
Lube Oil (MIL-PRF-7808)
Lube Oil (MIL-L-23699)
5% NaCl (A-A-694)
Followed by tests for:
Tensile Strength
Ultimate Elongation
Dielectric Strength
MPa (psi)
percent
kV/mm
(V/mil)
5.2 (750) minimum
100 minimum
7.9 (200) minimum
5.2 (750) minimum
100 minimum
7.9 (200) minimum
SAE-AMS-DTL-23053
ASTM D 638
ASTM D 638
ASTM D 2671
*Note 2
*Note 1: Recover specimens on the metal mandrels for 10 minutes minimum at 200 3C or until the tubing is completely
recovered on the mandrels.
*Note 2: For dielectric strength, immerse the recovered specimens in the fluids for 24 hours at 50 ± 2°C. After drying, place the
specimens over closest fitting metal mandrels.

CB5012-000

Mfr. #:
Manufacturer:
TE Connectivity
Description:
Heat Shrink Tubing and Sleeves BSTS-07X25
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union