CURRENT TRANSFER RATIO (T
amb
= 25 °C, unless otherwise specified)
PARAMETER TEST CONDITION PART SYMBOL MIN. TYP. MAX. UNIT
Current transfer
ratio
I
F
= 16 mA, V
O
= 0.4 V, V
CC
= 4.5 V
6N135 CTR 7 16 - %
6N136 CTR 19 35 - %
I
F
= 16 mA, V
O
= 0.5 V, V
CC
= 4.5 V
6N135 CTR 5 - - %
6N136 CTR 15 - - %
SWITCHING CHARACTERISTICS (T
amb
= 25 °C, unless otherwise specified)
PARAMETER TEST CONDITION PART SYMBOL MIN. TYP. MAX. UNIT
High to low
I
F
= 16 mA, V
CC
= 5 V, R
L
= 4.1 kΩ 6N135 t
PHL
-0.31.5μs
I
F
= 16 mA, V
CC
= 5 V, R
L
= 1.9 kΩ 6N136 t
PHL
-0.20.8μs
Low to high
I
F
= 16 mA, V
CC
= 5 V, R
L
= 4.1 kΩ 6N135 t
PLH
-0.31.5μs
I
F
= 16 mA, V
CC
= 5 V, R
L
= 1.9 kΩ 6N136 t
PLH
-0.20.8μs
COMMON MODE TRANSIENT IMMUNITY (T
amb
= 25 °C, unless otherwise specified)
PARAMETER TEST CONDITION PART SYMBOL MIN. TYP. MAX. UNIT
High
I
F
= 0 mA, V
CM
= 10 V
P-P
, V
CC
= 5 V, R
L
= 4.1 kΩ 6N135 |CM
H
| - 1000 - V/μs
I
F
= 0 mA, V
CM
= 10 V
P-P
, V
CC
= 5 V, R
L
= 1.9 kΩ 6N136 |CM
H
| - 1000 - V/μs
Low
I
F
= 16 mA, V
CM
= 10 V
P-P
, V
CC
= 5 V, R
L
= 4.1 kΩ 6N135 |CM
L
| - 1000 - V/μs
I
F
= 16 mA, V
CM
= 10 V
P-P
, V
CC
= 5 V, R
L
= 1.9 kΩ 6N136 |CM
L
| - 1000 - V/μs
SAFETY AND INSULATION RATINGS
PARAMETER TEST CONDITION SYMBOL VALUE UNIT
Climatic classification According to IEC 68 part 1 55 / 100 / 21
Pollution degree According to DIN VDE 0109 2
Comparative tracking index Insulation group IIIa CTI 175
Maximum rated withstanding isolation voltage According to UL1577, t = 1 min V
ISO
5300 V
RMS
Maximum transient isolation voltage According to DIN EN 60747-5-5 V
IOTM
8000 V
peak
Maximum repetitive peak isolation voltage According to DIN EN 60747-5-5 V
IORM
890 V
peak
Isolation resistance
T
amb
= 25 °C, V
IO
= 500 V R
IO
≥ 10
12
Ω
T
amb
= 100 °C, V
IO
= 500 V R
IO
≥ 10
11
Ω
Output safety power P
SO
500 mW
Input safety current I
SI
300 mA
Input safety temperature T
S
175 °C
Creepage distance DIP-8 ≥ 7mm
Clearance distance DIP-8 ≥ 7mm
Creepage distance DIP-8, 400 mil, option 6 ≥ 8mm
Clearance distance DIP-8, 400 mil, option 6 ≥ 8mm
Creepage distance SMD-8, option 7 ≥ 8mm
Clearance distance SMD-8, option 7 ≥ 8mm
Creepage distance SMD-8, option 9 ≥ 8mm
Clearance distance SMD-8, option 9 ≥ 8mm
Insulation thickness DTI ≥ 0.4 mm