1Description
Interface converter for TTY transmission systems
PSM-ME-RS232/TTY-P
© PHOENIX CONTACT
Data sheet
The interface converter PSM-ME-RS232/TTY-P converts
RS-232 interface signals bidirectionally to the TTY
standard.
The interface converter is snapped onto standard EN DIN
rails in the switch cabinet and supplied with 24VDC or AC.
Possible applications:
Interface adaptation to TTY devices
Permanent line for process data evaluation
Temporary programming connections
Features
Transmission distances of up to 1000m in active TTY
mode
High-quality 3-way isolation up to 2kV
(VCC // V.24 (RS-232) // TTY)
Integrated surge protection with transient discharge to
the DIN rail
Conversion of RS-232 TxD/RxD full duplex data signals
to the TTY current loop standard
Semi-active, active or passive TTY mode, depending
on pin assignment
Logical signal position can be inverted via plug-in
bridge
Active data transmission indicated by separate data
indicators for the transmit and receive channels
RS-232 connection via 9-pos. D-SUB and standard
RS-232 cable
Transmission speed of up to 19.2kbps
Make sure you always use the latest documentation.
It can be downloaded from the product at phoenixcontact.net/products
.
100275_en_02
2016-09-15
PSM-ME-RS232/TTY-P
100275_en_02 PHOENIX CONTACT 2 / 13
2Table of contents
1 Description .............................................................................................................................. 1
2 Table of contents..................................................................................................................... 2
3 Ordering data .......................................................................................................................... 3
4 Technical data ......................................................................................................................... 3
5 Safety notes............................................................................................................................. 6
5.1 UL Notes ........................................................................................................................... 6
6 Application examples .............................................................................................................. 7
7 Structure.................................................................................................................................. 8
7.1 Dimensions ........................................................................................................................ 8
7.2 Function elements ............................................................................................................... 9
8 RS-232 interface...................................................................................................................... 9
8.1 Configuration.................................................................................................................... 10
8.2 DTE/DCE adjustment ......................................................................................................... 10
9 TTY interface ......................................................................................................................... 11
9.1 Operating modes............................................................................................................... 11
9.2 Inversion of signal layer ....................................................................................................... 12
9.3 Connecting the data cables .................................................................................................. 12
10 Assembly............................................................................................................................... 13
10.1 Removal.......................................................................................................................... 13
10.2 Power supply.................................................................................................................... 13
PSM-ME-RS232/TTY-P
100275_en_02 PHOENIX CONTACT 3 / 13
Description Ty pe Order No. Pcs./Pkt.
Interface converter, for converting RS-232 (V.24) to TTY,
with electrical isolation, 2 channels, rail-mountable
PSM-ME-RS232/TTY-P 2744458 1
3Ordering data
Accessories Ty pe Order No. Pcs./Pkt.
RS-232 cable, 9-pos. D-SUB socket 25-pos on D-SUB
socket
PSM-KA 9 SUB 25/BB/
2METER
2761059 1
RS-232 cable, 9-pos. D-SUB socket on 9-pos. D-SUB
socket, 9-wire, 1:1
PSM-KA9SUB9/BB/2METER 2799474 1
Shield connection clip for printed circuit terminal block ME-SAS 2853899 10
Actuation tool, for ST terminal blocks, also suitable for use
as a bladed screwdriver, size: 0.6 x 3.5 x 100 mm,
2-component grip, with non-slip grip
SZF 1-0,6X3,5 1204517 10
D-SUB connector, 9-pos., male connector, one cable
entry < 35°, universal type for all systems, pin assignment:
1, 2, 3, 4, 5, 6, 7, 8, 9 to screw connection terminal block
SUBCON 9/M-SH 2761509 1
4 Technical data
Supply
Nominal supply voltage 24 V AC/DC ±20 %
(via pluggable COMBICON screw terminal block)
Typical current consumption 75 mA (24 V DC)
Protective circuit Surge protection (Suppressor diode)
Electrical isolation VCC // V.24 (RS-232) // TTY
Test voltage data interface/power supply 2 kV
rms
(50 Hz, 1 min.)
Torque 0.56 Nm ... 0.79 Nm
V.24 (RS-232) interface in acc. with ITU-T V.28, EIA/TIA-232, DIN 66259-1
Transmission channels 2 (1/1), RxD, TxD, full duplex
Connection method D-SUB9 plug
Conductor cross section 0.2 mm² ... 2.5 mm² (24 AWG ... 13 AWG)
Serial transmission speed 19.2 kbps
Transmission length 15 m (shielded twisted pair)
Protocols supported transparent protocol
Pin assignment DTE/DCE switchover via switch

2744458

Mfr. #:
Manufacturer:
Phoenix Contact
Description:
Terminal Block Interface Modules PSM-ME-RS 232/TTY-P
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet