Page 6 ams Datasheet
Document Feedback [v1-01] 2016-Aug-30
TSL1401CL − Absolute Maximum Ratings
Stresses beyond those listed under Absolute Maximum Ratings
may cause permanent damage to the device. These are stress
ratings only. Functional operation of the device at these or any
other conditions beyond those indicated under Electrical
Characteristics is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect device
reliability.
Figure 5:
Absolute Maximum Ratings over Operating Free-Air Temperature Range (unless otherwise noted)
Symbol Parameter Min Max Unit
V
DD
Supply voltage range -0.3 6 V
V
I
Input voltage range -0.3
V
DD
+ 0.3V
V
I
IK
Input clamp current, (V
I
< 0) or (V
I
> V
DD
)
-20 20 mA
I
OK
Output clamp current, (V
O
< 0) or (V
O
> V
DD
)
-25 25 mA
V
O
Voltage range applied to any output in the high impedance or
power-off state
-0.3
V
DD
+ 0.3V
V
I
O
Continuous output current, (V
O
= 0 to V
DD
)
-25 25 mA
Continuous current through V
DD
or GND
-40 40 mA
I
O
Analog output current range -25 25 mA
Maximum light exposure at 638nm 5
mJ/cm
2
T
A
Operating free-air temperature range -25 85 °C
T
STRG
Storage temperature range -25 85 °C
ESD
HBM
ESD tolerance, human body model ±2000 V