Basic Force Sensors, TBF Series, Compensated/Unamplified
Table 7. Pressure Range Specifications for 100 kPa to 1 MPa
Pressure Range
Order Code
(see Figure 1)
Pressure
Range
Unit
Overpressure
Pressure
Accuracy
1
(%FSS)
Offset
2
(mV/V)
Full Scale Span
3
(mV/V)
Thermal Effect
on Offset
4
(%FSS)
Thermal Effect
on Span
5
(%FSS)
Pmin. Pmax. Min. Nom. Max.
0 ºC
to
50 ºC
0 ºC
to
50 ºC
Gage
100KG 0 100 kPa 400 ±0.5 ±0.3 4.90 5.10 5.30 ±1.0 ±1.0
160KG 0 160 kPa 400 ±0.5 ±0.3 7.84 8.15 8.48 ±1.0 ±1.0
250KG 0 250 kPa 800 ±0.5 ±0.15 6.10 6.35 6.59 ±1.0 ±0.75
400KG 0 400 kPa 1000 ±0.5 ±0.075 5.57 5.80 6.04 ±1.0 ±0.75
600KG 0 600 kPa 1700 ±0.5 ±0.075 5.08 5.30 5.54 ±0.75 ±0.75
001GG 0 1 MPa 1.70 ±0.5 ±0.075 8.47 8.85 9.22 ±0.50 ±0.75
1
Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the pressure
range at 25 °C [77 °F]. Includes all errors due to pressure non-linearity, pressure hysteresis, and non-repeatability.
2
Offset: The output signal obtained when the reference pressure is applied to all available pressure ports. Also known as “null” or
zero”.
3
Full Scale Span: The algebraic difference between the output signal measured at the maximum and minimum limits of the
pressure range (see Figure 1).
4
Thermal effect on offset: The deviation in offset due to changes in temperature over the compensated temperature range, relative
to offset measured at 25 ºC.
5
Thermal effect on span: The deviation in full scale span due to changes in temperature over the compensated temperature range,
relative to full scale span measured at 25 ºC.
Table 8. Pressure Range Specifications for 15 psi to 150 psi
Pressure Range
Order Code
(see Figure 1)
Pressure
Range
Unit
Overpressure
Pressure
Accuracy
1
(%FSS)
Offset
2
(mV/V)
Full Scale Span
3
(mV/V)
Thermal Effect
on Offset
4
(%FSS)
Thermal Effect
on Span
5
(%FSS)
Pmin. Pmax. Min. Nom. Max.
0 ºC
to
50 ºC
0 ºC
to
50 ºC
Gage
015PG 0 15 psi 60 ±0.5 ±0.3 5.06 5.25 5.49 ±1.0 ±1.0
030PG 0 30 psi 115 ±0.5 ±0.15 5.05 5.25 5.45 ±1.0 ±0.75
060PG 0 60 psi 145 ±0.5 ±0.075 5.76 6.00 6.24 ±1.0 ±0.75
100PG 0 100 psi 245 ±0.5 ±0.075 5.83 6.10 6.36 ±0.75 ±0.75
150PG 0 150 psi 245 ±0.5 ±0.075 8.65 9.15 9.55 ±0.50 ±0.75
1
Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the pressure
range at 25 °C [77 °F]. Includes all errors due to pressure non-linearity, pressure hysteresis, and non-repeatability.
2
Offset: The output signal obtained when the reference pressure is applied to all available pressure ports. Also known as “null” or
zero”.
3
Full Scale Span: The algebraic difference between the output signal measured at the maximum and minimum limits of the
pressure range (see Figure 1).
4
Thermal effect on offset: The deviation in offset due to changes in temperature over the compensated temperature range, relative
to offset measured at 25 ºC.
5
Thermal effect on span: The deviation in full scale span due to changes in temperature over the compensated temperature range,
relative to full scale span measured at 25 ºC.
5
Sensing and Productivity Solutions
Basic Force Sensors, TBF Series, Compensated/Unamplified
Figure 1. Nomenclature and Order Guide
Basic Force Sensors
TBF Series, Compesated/Unamplied
Product Nomenclature
008302-1-EN IL50
January 2016
Copyright © 2016 Honeywell International Inc. All Rights Reserved.
TBF L PN S 150PG U C V
U
Series
Output
TBF
Unamplified
For example, TBFLPNS150PGUCV defines a TBF Series Basic Force Sensor, Leadless SMT package,
low-profile pressure port, silicone gel interface, 0 psi to 150 psi gage pressure range, unamplified output,
compensated, constant supply voltage.
L
Leadless SMT (Surface Mount Technology)
Package
Gel Coating Option
PN
Low-profile
port
C
Compensation
Compensated
V
Supply Voltage
Constant
S
Silicone gel interface
Pressure Port
Pressure Range
15 psi to 150 psi1 bar to 10 bar 100 kPa to 1 MPa
Gage
Gage
015PG
030PG
060PG
100PG
150PG
001BG
1.6BG
2.5BG
004BG
006BG
010BG
0 bar to 1 bar
0 bar to 1.6 bar
0 bar to 2.5 bar
0 bar to 4 bar
0 bar to 6 bar
0 bar to 10 bar
Gage
100KG
160KG
250KG
400KG
600KG
001GG
0 kPa to 100 kPa
0 kPa to 160 kPa
0 kPa to 250 kPa
0 kPa to 400 kPa
0 kPa to 600 kPa
0 MPa to 1 MPa
0 psi to 15 psi
0 psi to 30 psi
0 psi to 60 psi
0 psi to 100 psi
0 psi to 150 psi
Basic force sensor
Figure 2. Leadless SMT Package Dimensional Drawings (For reference only: mm [in].)
1
[0.039]
2,5 Typ.
[0.098]
1,02
[0.040]
3,89
[0.153]
6,5
[0.26]
3,5
[0.138]
7
[0.276]
3,5
[0.138]
7
[0.276]
1
2
3
6
5
4
7,62
[0.300]
2,50
[0.098]
1,27
[0.050]
2,54
[0.100]
Function Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6
analog Vs NC Vo- GND NC Vo+
Sensor Mounting Pad Layout
Find out more
Honeywell serves its customers through
a worldwide network of sales offices,
representatives and distributors.
For application assistance, current
specifications, pricing or name of the
nearest Authorized Distributor, contact
your local sales office.
To learn more about Honeywell Sensing
and Productivity Solutions’ products, call
+1-815-235-6847 or 1-800-537-6945,
visit sensing.honeywell.com, or e-mail
inquiries to info.sc@honeywell.com
Sensing and Productivity Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422
honeywell.com
Warranty/Remedy
Honeywell warrants goods of its manufacture as being free
of defective materials and faulty workmanship. Honeywell’s
standard product warranty applies unless agreed to
otherwise by Honeywell in writing; please refer to your order
acknowledgement or consult your local sales office for specific
warranty details. If warranted goods are returned to Honeywell
during the period of coverage, Honeywell will repair or replace,
at its option, without charge those items it finds defective.
The foregoing is buyer’s sole remedy and is in lieu of all
other warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.
While we provide application assistance personally, through our
literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
WARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the product
could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
WARNING
MISUSE OF DOCUMENTATION
The information presented in this datasheet is for reference
only. Do not use this document as a product installation
guide.
Complete installation, operation, and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
32315675-A-EN IL50
January 2016
© 2016 Honeywell International Inc. All rights reserved.
ADDITIONAL INFORMATION
The following associated literature is available at
sensing.honeywell.com:
Product Range Guide
Product Line Guide
Product Installation Instructions
Technical Information:
- Output Signal Adjustment and Temperature
Compensation for Honeywell Basic Force Sensors, TBF
Series, Compensated/Unamplified

TBFLPNS001BGUCV

Mfr. #:
Manufacturer:
Description:
Force Sensor Module 6-Pin SMD Module
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union