Technical data
Max. operating temperature
Top,max
+125 °C
Dissipation factor tan δ (in 10
-3)
at 20 °C (upper limit values)
C
R
0.1 µF 0.1 µF< C
R
at 1 kHz
100 kHz
1 (typically 0.6)
5.0
1.0
Insulation resistance R
ins
or time constant τ = C
R
R
ins
at 20 °C, rel. humidity 65%
(minimum as-delivered values)
> 30 000 M
> 10 000 s
(C
R
0.33 µF)
(C
R
> 0.33 µF)
Total self-inductance L
(lead length 3mm)
LS 15 mm
LS 22.5 mm
10 nH
18 nH
DC test voltage
1.6 × V
R
, 2 s
Category voltage V
C
(continuous operation with
V
DC
or V
AC
at f 1 kHz)
T
A
(°C) DC voltage derating AC voltage derating
T
A
85
85<T
A
110
V
C
= V
R
V
C
= V
R
(165T
A
)/80
V
C,RMS
= V
RMS
V
C,RMS
=V
RMS
(165T
A
)/80
Operating voltage V
op
for
short operating periods
(V
DC
or V
AC
at f 1 kHz)
T
A
(°C) DC voltage (max. hours) AC voltage (max. hours)
T
A
100
100<T
A
125
V
op
= 1.25 V
C
(2000 h)
V
op
= 1.25 V
C
(1000 h)
V
op
= 1.0 V
C,RMS
(2000 h)
V
op
= 1.0 V
C,RMS
(1000 h)
Passive flammability category
in accordance to
IEC 40 (CO) 752 C
Maximum continuous
AC voltage V
AC
220 V / 277 V / 310 V (50/60 Hz)
Rated AC voltage
(IEC 60384-14) 250 V (50/60 Hz)
Surge pulse test IEC 1000-4-5 1.2 µs / 50 µs / 1200 V
8.0 µs / 20 µs / 1200 V
Damp heat test 56 days / 40 °C / 93% relative humidity
Limit values after
damp heat test
Capacitance change C/C
Dissipation factor change tan δ
Insulation resistance R
ins
or time constant τ = C
R
R
ins
5%
0.5 10
-3
(at 1 kHz)
1.0 10
-3
(at 10 kHz)
50% of minimum
as-delivered values
Reliability:
Failure rate λ
Service life t
SL
1 fit (1 10
-9
/h) at 0.5 V
R
, 40 °C
200 000 h at 1.0 V
R
, 85 °C
For conversion to other operating conditions and temperatures,
refer to chapter "Quality, 2 Reliability".
B32671Z ... B32673Z
Power Factor Correction
Page 7 of 20Please read Cautions and warnings and
Important notes at the end of this document.
Failure criteria:
Total failure Short circuit or open circuit
Failure due to variation
of parameters
Capacitance change C/C
Dissipation factor tan δ
Insulation resistance R
ins
> 10%
> 4 upper limit values
< 1500 M
Pulse handling capability
"dV/dt" represents the maximum permissible voltage change per unit of time for non-sinusoidal
voltages, expressed in V/µs.
"k
0
" represents the maximum permissible pulse characteristic of the waveform applied to the
capacitor, expressed in V
2
/µs.
Note:
The values of dV/dt and k
0
provided below must not be exceeded in order to avoid damaging the
capacitor.
dV/dt values
Lead spacing 10 mm 15 mm 22.5 mm
V
R
V
RMS
V DC V AC dV/dt in V/µs
450 220 160 100
520 277 200 120
630 310 400 250 160
k
0
values
Lead spacing 10 mm 15 mm 22.5 mm
V
R
V
RMS
V DC V AC k
0
in V
2
/µs
450 220 128 000 80 000
520 277 208 000 125 000
630 310 504 000 504 000 202 000
B32671Z ... B32673Z
Power Factor Correction
Page 8 of 20Please read Cautions and warnings and
Important notes at the end of this document.
Permissible AC voltage V
RMS
versus frequency f (for sinusoidal waveforms T
A
90 °C)
For T
A
>90 °C, please refer to "General technical information", section 3.2.3.
Lead spacing 10 mm
630 V DC/310 V AC
B32671Z
Power Factor Correction
Page 9 of 20Please read Cautions and warnings and
Important notes at the end of this document.

B32672Z4684J000

Mfr. #:
Manufacturer:
EPCOS / TDK
Description:
Film Capacitors FILM CAP 0.56uF 10% 630Vdc LS 22.5mm
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: