MM201C155KCZ2A

128
113016
MM Series – MLCC for Medical Applications
X7R Specifications and Test Methods
Parameter/Test X7R Specification Limits Measuring Conditions
Operating Temperature Range -55ºC to +125ºC Temperature Cycle Chamber
Capacitance Within specified tolerance
≤ 10% for ≥ 50V DC rating Freq.: 1.0 kHz ± 10%
Dissipation Factor
≤ 12.5% for 25V DC rating Voltage: 1.0Vrms ± .2V
≤ 12.5% for 25V and 16V DC rating
≤ 12.5% for ≤ 10V DC rating
Insulation Resistance
100,000MΩ or 1000MΩ - μF, Charge device with rated voltage for
whichever is less 120 ± 5 secs @ room temp/humidity
Charge device with 300% of rated voltage for
Dielectric Strength No breakdown or visual defects 1-5 seconds, w/charge and discharge current
limited to 50 mA (max)
Note: Charge device with 150% of rated
voltage for 500V devices.
Appearance No defects Deflection: 2mm
Capacitance Test Time: 30 seconds
Resistance to Variation
≤ ±12%
Flexure Dissipation
Meets Initial Values (As Above)
Stresses Factor
Insulation
≥ Initial Value x 0.3
Resistance
Solderability
≥ 95% of each terminal should be covered Dip device in eutectic solder at 230 ± 5ºC
with fresh solder for 5.0 ± 0.5 seconds
Appearance No defects, <25% leaching of either end terminal
Capacitance
Variation
≤ ±7.5%
Dip device in eutectic solder at 260ºC for 60
Dissipation
Meets Initial Values (As Above)
seconds. Store at room temperature for 24 ± 2
Resistance to
Factor
hours before measuring electrical properties.
Solder Heat
Insulation
Meets Initial Values (As Above)
Resistance
Dielectric
Meets Initial Values (As Above)
Strength
Appearance No visual defects Step 1: -55ºC ± 2º 30 ± 3 minutes
Capacitance
Variation
≤ ±7.5% Step 2: Room Temp ≤ 3 minutes
Dissipation
Meets Initial Values (As Above) Step 3: +125ºC ± 2º 30 ± 3 minutes
Thermal
Factor
Shock
Insulation
Meets Initial Values (As Above) Step 4: Room Temp ≤ 3 minutes
Resistance
Dielectric
Meets Initial Values (As Above)
Repeat for 5 cycles and measure after
Strength 24 ± 2 hours at room temperature
Appearance No visual defects
Capacitance
Variation
≤ ±12.5%
Dissipation
≤ Initial Value x 2.0 (See Above)
Load Life Factor
Insulation
≥ Initial Value x 0.3 (See Above)
Resistance
Dielectric
Meets Initial Values (As Above)
Strength
Appearance No visual defects
Capacitance
Variation
≤ ±12.5%
Load Dissipation
≤ Initial Value x 2.0 (See Above)
Humidity Factor
Insulation
≥ Initial Value x 0.3 (See Above)
Resistance
Dielectric
Meets Initial Values (As Above)
Strength
Charge device with 1.5 rated voltage (≤ 10V) in
test chamber set at 125ºC ± 2ºC
for 1000 hours (+48, -0)
Remove from test chamber and stabilize
at room temperature for 24 ± 2 hours
before measuring.
Store in a test chamber set at 85ºC ± 2ºC/
85% ± 5% relative humidity for 1000 hours
(+48, -0) with rated voltage applied.
Remove from chamber and stabilize at
room temperature and humidity for
24 ± 2 hours before measuring.
1mm/sec
90 mm
110116
129
MM Series – MLCC for Medical Applications
X7R Capacitance Range
SIZE 0402 0603 0805 1206 1210 1808 1812 2220
WVDC 16 25 50 10 16 25 50 100 200 10 16 25 50 100 200 250 10 16 25 50 100 200 250 500 10 16 25 50 100 200 250 500 50 100 200 50 100 200 250 25 50 100
Cap 220 221
pf 270 271
330 331
390 391
470 471
560 561
680 681
820 821
1000 102
1200 122
1500 152
1800 182
2200 222
2700 272
3300 332
3900 392
4700 472
5600 562
6800 682
8200 822
cap 0.010 103
uf 0.012 123
0.015 153
0.018 183
0.022 223
0.027 273
0.033 333
0.039 393
0.047 473
0.056 563
0.068 683
0.082 823
0.10 104
0.12 124
0.15 154
0.22 224
0.33 334
0.47 474
0.56 564
0.68 684
0.82 824
1.0 105
1.2 125
1.5 155
WVDC 16 25 50 10 16 25 50 100 200 10 16 25 50 100 200 250 10 16 25 50 100 200 250 500 10 16 25 50 100 200 250 500 50 100 200 50 100 200 250 25 50 100
SIZE 0402 0603 0805 1206 1210 1808 1812 2220
PREFERRED SIZES ARE SHADED

MM201C155KCZ2A

Mfr. #:
Manufacturer:
N/A
Description:
CAP CER 1.5UF 100V X7R 2220
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: