AAV Sensors
- 23 -
www.nve.com phone: 952-829-9217 fax: 952-829-9189
Functional Block Diagram, Marking, and Pinout, AAV002-11:
Specifications:
Parameter
Test
Condition Min Typ Max Units
Nominal Resistance of Each Resistor 25°C 1200 1500 1800 Ohms
Maximum Resistance Decrease with Field
Change
Operating at
25°C
4.5% 5.2% 7%
Required Strength of Applied Magnetic Field Operating 30 200 Oersted
2
Measurement Error Operating 2 Degrees
Supply Voltage Operating 12 Volts
Offset Voltage Operating at
25°C
-10 10 mV/V
Temperature Range of Operation Operating -40 150
°C
Storage Temperature -40 170
°C
Temperature Coefficient of Resistance Operating +0.3
%/°C
TCOV
3
Operating -0.24
%/°C
TCOI
3
Operating -0.16
%/°C
Notes:
1. Large Magnetic Fields WILL NOT cause damage to NVE GMR Sensors.
2. 1 Oe (Oersted) = 1 Gauss in air = 0.1 mTesla = 79.8 Amps/meter.
3. TCOV is the percent change in output signal over temperature with a constant voltage source powering the part and TCOI
is the percent change in output over temperature with a constant current source.
BBQ
R3 (Cosine)
R4 (Cosine)
R2 (Sine)
R1 (Sine)
VCC
Cos
GND
Sin
Cosine Output Sine Output