Installation Environment
Do not install the Output Block in the following locations or
damage or malfunction may result.
-
Locations with direct sunlight.
-
Locations with ambient temperature ranges not within --25
°
C
to 55
°
C(--13
°
F to 131
°
F).
-
Locations with rapid temperature changes resulting in
condensation or relative humidity exceeding 45% to 85%.
-
Locations with corrosive or inflammable gas.
-
Locations with excessive dust, salinity, or metal powder.
-
Locations with vibration or shock affecting the Output Block.
-
Locations with water, oil, or chemical sprayed on the Output
Block.
Screw Tightening Torque
Tighten all screws of the Output Block properly, or the Output
Block may malfunction.
-
Terminal screws: Tighten each terminal screw to a torque of
0.78 to 1.18 N
:
m.
-
Mounting screws: Tighten each mounting screw to a torque
of 0.59 to 0.98 N
:
m
-
Relay block mounting screws: Tighten each mounting screw
to a torque of 0.59 to 0.98 N
:
m.
Cleaning
Do not use paint thinner to clean the surface because damage or
discoloration may result.
Handling
Do not drop the Output Block or shock or vibrate the Output
Block excessively. This may damage the Output Block and result
in malfunction.
Disassembling, Repairing, and Modifying
Do not disassemble, repair, or modify the Output Block. An
electric shock may result or the Output Block may malfunction.
Output Block Configuration
G70D-SOC/G70D-FOM
To open the protective cover, lift cover at both points marked “A”
in the following illustration.
Use the Relay Removal Tool provided to the left of the screw
terminals when replacing relays.
G70D-VSOC/G70D-VFOM
For ease-of-use and space-saving, the G70D-VSOC16
incorporates a terminal block and relay block that can be
separated from the Output Block. The relay block has operation
indicators and replaceable Relays along with electrical check
terminals for monitoring the operation of the Output Block.
The Expansion Terminal Block can be mounted to the Output
Block for power line connections.
Relay block
Terminal block
Expansion
terminal block
Removing and Mounting the Terminal Block and
Relay Block
Refer to the diagram below.
1. Removing
Check that the load and the Output Block are both turned OFF.
Turn the mounting screws of the relay block counterclockwise
alternately and equally until the relay block is slightly raised.
When the relay block is slightly raised, disconnect the protruding
part A of the relay block from the interior wall of the Output Block.
Further turn the mounting screws counterclockwise and remove
the mounting screws. Then remove the relay block.
2. Mounting
Check that the load and the Output Block are both turned OFF.
Check that the part B of he terminal block is free of metal dust or
other foreign materials.
Mount the relay block straight along the groove of the terminal
block.
Press the both ends of the relay block and place the protruding
part A onto the interior wall of the Output Block.
Tighten the mounting screws of the relay block clockwise
alternately and equally to secure the relay block
Mounting screws
Relay block
Terminal block
G70D
G70D
Nameplate of Terminal Block
As shown in Figure 1, the nameplate of the terminal block is
located on the bottom surface of the relay block.
To fill in the nameplate, remove the nameplate from the relay
block. Then return it to the original location when finished.
To read the nameplate after the Output Block is mounted to a
panel, for example, pull out the nameplate from the bottom
surface of the relay block as shown in Figure 2.
Relay block
Nameplate
Figure 1
Nameplate
Figure 2
Mounting the Expansion Terminal Block
Insert the hooks of the Expansion Terminal Block into the
mounting holes on the terminal block and slide the Expansion
Terminal Block so that it will not separate from the terminal block.
Tighten the mounting screw of the Expansion Terminal Block
securely.
Terminal block
Mounting screw
Expansion Terminal Block
Electrical Check Terminals
The terminal block of the G70D-VSOC16 in operation is located
under the relay block. Therefore, unlike the terminal blocks of
other models, electrical checks on the terminals are not possible
with multimeter probes. The relay block of the G70D-VSOC16,
however, incorporates electrical check terminals, each of which is
connected to the corresponding terminal of the terminal block. All
the pairs of these terminals share single terminal numbers
respectively.
To check these terminals, apply multimeter probes to these
terminals.
Do not touch these energized terminals with a thin metal object
or similar objects. Doing so may result in an electric shock.
Multimeter probes
Electrical check terminals
Cat.No.J099-E3-104/00Specificationssubjecttochangewithoutnotice.PrintedinU.S.A.
OMRON ELECTRONICS, INC.
OneEastCommerceDrive
Schaumburg, IL 60173
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.
1-800-55-OMRON
OMRON CANADA, INC.
885 Milner Avenue
Scarborough, Ontario M1B 5V
416-286-6465
9

G79-200C

Mfr. #:
Manufacturer:
Omron Automation and Safety
Description:
Relay Sockets & Hardware RlyBlock 200H CBL 2M
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union