B58601H8000A036

Pressure sensors
C32 series Gauge pressure sensor die
Preliminary data
AS SEN PD 2009-08-03
Please read Cautions and warnings and Page 4 of 8
Important notes at the end of this document.
Operating pressures and ordering codes
Parameter @ 25 °C, V
DD
= 5 V Symbol Typ. Typ. Typ. Typ. Units
Operating pressure
4)
p
r
1.6 4 10 25 bar
Nonlinearity
14)
[typ/max] L ±0.2/±0.3 ±0.2/±0.3 ±0.2/±0.3 ±0.2/±0.3 % FS
Sensitivity
13)
[min/typ/max]
S 45/70/95 23/30/38 9/12/15 3.6/4.8/6 mV/bar
Product type
AER 1.600 C32/2 F00 G08 N
AER 4.000 C32/2 F00 G08 N
AER 10.00 C32/2 F00 G08 N
AER 25.00 C32/2 F00 G08 N
Ordering code
B58601H8000A035
B58601H8000A033
B58601H8000A036
B58601H8000A034
Other operating pressures upon request.
Pressure sensors
C32 series Gauge pressure sensor die
Preliminary data
AS SEN PD 2009-08-03
Please read Cautions and warnings and Page 5 of 8
Important notes at the end of this document.
Symbols and Terms
1)
Maximum power supply V
DD
This is the maximal allowed voltage, which may be applied to the piezoresistive bridge circuit without damage.
2)
Operating temperature range T
a
This is the operating Temperature range T
a,min
to T
a,max
.
Because most of the sensor parameters depend on assembling
conditions like gluing, wire bonding etc, the die has to be tested over the operating temperature range by the customer
fully assembled. For design verification and process control samples, mounted in AK transducer package (AK2 series)
are tested over a reduced measuring temperature range of T
meas,min
to T
meas,max
.
3)
Storage temperature range T
st
If the pressure sensor dies are stored in the temperature range T
st,min
to T
st,max
without applied voltage power supply, this
will not affect the performance of the pressure sensor dies.
4)
Operating pressure range p
r
In the operating pressure range 0 to p
r,max
the pressure sensor die output characteristic is as defined in this specification.
5)
Over pressure p
OV
Pressure cycles in the pressure range 0 to p
ov
do not affect the performance of the pressure sensor dies.
6)
Burst pressure p
berst
Up to the burst pressure p
berst
the diaphragm of the sensor die will not be destroyed mechanically. This parameter is
tested at room temperature on samples mounted on an aluminium socket by increasing the applied pressure until the
diaphragm is destroyed.
7)
Operating power supply V
DD
The pressure sensor parameters are defined for a power supply voltage of V
DD
= 5 V. In the operating power supply
voltage range V
DD,min
to V
DD,max
the ratiometric parameters r(V
DD
) like sensitivity, offset voltage and the temperature
coefficient of the offset voltage are defined by:
( )
]V[5
V
])V[5(rVr
DD
DD
=
8)
Total bridge resistance R
S
The total bridge resistance is defined between pad X5 and X2, (see the dimensional drawing in this data sheet) of the
closed piezoresistive bridge circuit. The total bridge resistance is in a good approximation the output impedance of the
piezoresistive bridge circuit. This parameter is tested completely on a wafer (wafer level test measurement).
9)
Temperature coefficients of resistance α
αα
α
Rs
and β
ββ
β
Rs
:
The temperature coefficients of resistance are tested for design verification on samples, mounted on AK transducer
package (AK2 series) over a reduced temperature range T
meas
,
min
= –20 °C to T
meas
,
max
= 80 °C with T
R
= 25 °C.
The temperature coefficients of first and second order are defined with the polynomial:
(
)
(
)
°β+°α+°==
2
RsRs
SS
C25TC25T1)C25T(R)T(R
The coefficients α
Rs
and β
Rs
are calculated using the three measurement points of R
s
(T) at T
meas,min
, T
R
and T
meas,max
.
10)
Offset voltage V
0
The offset voltage V
0
is the output voltage V
out
(p = 0 bar gauge) at zero gauge pressure and for a bridge voltage power
supply V
DD
= 5 V. This parameter is tested completely on a wafer (wafer level test measurement).
It should be noted that this parameter may be influenced by assembly.
11)
Temperature coefficient of offset voltage TCV
0
The temperature coefficients of offset voltage are defined for a bridge voltage power supply V
DD
= 5 V.
These parameters strongly depend on assembly conditions like gluing, wire bonding etc.
The temperature coefficients of offset voltage are tested for design verification on samples, mounted on AK transducer
package (AK2 series) over a temperature range T
min
= –40 °C to T
max
= 135 °C.
Therefore TCV
0+
and TCV
0-
are defined for the measurement temperature range by:
C25T
)C25(V)T(V
TCVo
max
omaxo
°
°
=
+
C25T
)C25(V)T(V
TCVo
min
omino
°
°
=
Pressure sensors
C32 series Gauge pressure sensor die
Preliminary data
AS SEN PD 2009-08-03
Please read Cautions and warnings and Page 6 of 8
Important notes at the end of this document.
12)
Full scale value FS
omaxrout
V)p(VFS =
13)
Sensitivity S
The sensitivity is defined for a bridge voltage power supply V
DD
= 5 V. It can be determined by the formula:
maxr
omaxrout
p
V)p(V
S
=
This parameter is tested for process control on samples, mounted on AK transducer package (AK2 series).
14)
Nonlinearity L
This parameter may be influenced by assembly.
The nonlinearity is measured using the endpoint method. Assuming a characteristic, this can be approximated
by a polynomial of second order, where the maximum is at p
x
= p
rmax
/2. The nonlinearity is defined at p
x
= p
rmax
/2,
using the equation:
maxr
x
omaxrout
oxout
p
p
V)p(V
V)p(V
L
=
This parameter is tested for process control on samples, mounted on AK transducer package (AK2 series)..
15)
Temperature coefficient of sensitivity α
αα
α
S
and β
ββ
β
S
:
These parameters may be influenced by assembly.
The temperature coefficients of sensitivity are tested for design verification on samples, mounted on AK transducer
package (AK2 series) over a reduced temperature range T
meas
,
min
= –20 °C to T
meas
,
max
= 80 °C with T
R
= 25 °C.
The temperature coefficients of first and second order are defined with the polynomial:
( ) ( )
°β+°α+°==
2
SS
C25TC25T1)C25T(S)T(S
The coefficients α
S
and β
S
are calculated using the three measurement points of S(T) at T
meas,min
, T
R
and T
meas,max
.
16)
Pressure hysteresis pHys
The pressure hysteresis is the difference between output voltages at constant pressure and constant temperature while
applying a pressure cycle with pressure steps of p
r, min
, p
1
, p
2
, p
3
, p
r,max
, p
3
, p
2
, p
1
, p
r, min
:
FS
)p(V)p(V
pHys
k1,outk2,out
=
With k = min, 1, 2, 3, max. The pressure steps are: p
rmin
= 0, p
1
= 0.25·p
r,max
, p
2
= 0.5·p
r,max
, p
3
= 0.75·p
r, max
, p
r,max
.
This parameter is tested for design verification on samples, mounted on AK transducer package (AK2 series).
17)
Reliability data
For long-term stability of offset voltage LTSV
0
please refer to the defined Aktiv Sensor’s standard AS100001 in chapter
“Reliability data” on the internet.

B58601H8000A036

Mfr. #:
Manufacturer:
EPCOS / TDK
Description:
Board Mount Pressure Sensors 10.00 C32/2 F00 G08N Pressure Sensor AER
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet