1Description
Axioline E PROFINET device, metal housing,
16freely configurable inputs or outputs,
24VDC, M12 fast connection technology
AXL E PN DIO16 M12 6M
© PHOENIX CONTACT
Data sheet
The Axioline E device is designed for use within a
PROFINET network.
It is used to acquire and output digital signals.
The device is designed for use in systems manufacturing.
It is suitable for use without a control cabinet under harsh in-
dustrial conditions.
The Axioline E device can be used on tool platforms, directly
on welding robots or in conveying technology, for example.
PROFINET features
Connection to PROFINET network
using M12 connectors (D-coded)
2 Ethernet ports (with integrated switch)
Transmission speed 100 Mbps
PROFINET RT (RTC 1) supported
with minimum cycle time of 1 ms
Supported protocols: SNMP, LLDP, MRP, DCP
–PROFINET features:
FSU, shared device, MRP client, I&M functions 0 - 4
Specification:
Mapping in accordance with PROFINET
specification v2.2
Mapping as PROFINET IO device
(conformance class B)
Device description using GSDML file
–Firmware can be updated
Integrated web server for web-based management
AxiolineE features
Connection of digital sensors
to M12 connectors (A-coded)
Diagnostic and status indicators
Short-circuit and overload protection
of the sensor supply
IP65/67 degree of protection
This data sheet is only valid in association with the associated user manual.
Make sure you always use the latest documentation.
It can be downloaded from the product at phoenixcontact.net/products.
Abbreviations used:
– FSU: Fast startup
– MRP: Media Redundancy Protocol
– I&M: Identification and maintenance
8443_en_04
2015-10-15
AXL E PN DIO16 M12 6M
8443_en_04 PHOENIX CONTACT 2
2Table of contents
1 Description .............................................................................................................................. 1
2 Table of contents ..................................................................................................................... 2
3 Ordering data .......................................................................................................................... 3
4 Technical data ......................................................................................................................... 4
5 Internal circuit diagram ............................................................................................................ 7
6 Pin assignment ........................................................................................................................ 8
6.1 PROFINET and power supply connection .................................................................................. 8
6.2 PROFINET pin assignment .................................................................................................... 8
6.3 Pin assignment of the power supply U
S
/U
A
................................................................................. 8
6.4 Connecting inputs and outputs................................................................................................ 9
6.5 Pin assignment of the inputs and outputs................................................................................... 9
7 Connection example.............................................................................................................. 10
8 Connection notes .................................................................................................................. 10
9 Local status and diagnostic indicators ................................................................................... 11
9.1 Indicators for Ethernet ports and power supply.......................................................................... 11
9.2 Input and output indicators ................................................................................................... 12
10 PROFINET IO Device ............................................................................................................13
10.1 Status module................................................................................................................... 13
10.10 Device replacement ........................................................................................................... 16
10.11 I&M functions.................................................................................................................... 17
10.2 IO module........................................................................................................................ 13
10.3 Substitute value behavior..................................................................................................... 15
10.4 Swap byte order ................................................................................................................ 15
10.5 Diagnostic messages ......................................................................................................... 16
10.6 LLDP - Link Layer Discovery Protocol ..................................................................................... 16
10.7 MRP - Media Redundancy Protocol........................................................................................ 16
10.8 FSU - Fast Startup ............................................................................................................. 16
10.9 Shared device................................................................................................................... 16
11 Startup................................................................................................................................... 18
11.1 Delivery state/default settings ............................................................................................... 18
11.2 Starting the firmware .......................................................................................................... 18
11.3 Firmware update ............................................................................................................... 18
11.4 Restoring the default settings................................................................................................ 18
12 WBM - Web-based management .......................................................................................... 19
13 SNMP - Simple Network Management Protocol .................................................................... 19
14 Device description file (GSDML) ........................................................................................... 19
AXL E PN DIO16 M12 6M
8443_en_04 PHOENIX CONTACT 3
Description Type Order No. Pcs./Pkt.
AxiolineE PROFINET device in a metal housing with 16configurable in-
puts or outputs, 24VDC, M12 fast connection technology
AXL E PN DIO16 M12 6M 2701517 1
Accessories Type Order No. Pcs./Pkt.
An M12 screw plug for the unoccupied M12 sockets of the sensor/actuator
cable, boxes and flush-type connectors (Protection and sealing elements)
PROT-M12 1680539 5
Mounting plate for Axioline E metal devices (Assembly) AXL E MP 60 2701761 1
Snap-in markers, Sheet, white, unlabeled, can be labeled with:
THERMOMARK CARD, BLUEMARK CLED, BLUEMARK LED,
TOPMARK LASER, Mounting type: snapped into marker carrier,
Lettering field: 7 x 10 mm (Marking)
UCT-EM (7X10) 0830765 10
Documentation Type Order No. Pcs./Pkt.
User manual, English, Axioline E: system and installation UM EN AXL E SYS INST - -
Application note, English, Starting up Axioline E PROFINET devices
using PC Worx
AH EN AXL E PN PCWORX - -
Application note, English, Startup of Axioline E PROFINET devices
on a SIMATIC
®
S7 controller (for experienced S7 users)
AH EN S7 - AXL E PN PRO - -
Additional ordering data
For additional accessories, visit phoenixcontact.net/products.
3Ordering data

2701517

Mfr. #:
Manufacturer:
Phoenix Contact
Description:
Terminal Block Interface Modules AXL E PN DIO16 M12 6M
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet