2902959

MINI MCR-SL-PTB-FM
105449_en_00 PHOENIX CONTACT 4
4 Technical data
Input
Input voltage 0 V DC ... 30 V DC
Max. input current 2 A
Protection against polarity reversal Yes
Output
Output voltage (Input voltage - 0.8 V)
Output current 2 A
Diagnostic and status indicators
Status display Green LED (supply)
Indication Red LED
General data
Maximum temperature coefficient < 0.01 %/K
Mounting position Any
Degree of protection IP20
Dimensions W / H / D 6.2 mm / 93.1 mm / 102.5 mm
Type of housing PBT green
Connection data Screw connection Spring-cage conn.
Conductor cross section, solid 0.2 mm² ... 2.5 mm² 0.2 mm² ... 2.5 mm²
Conductor cross section, stranded 0.2 mm² ... 2.5 mm² 0.2 mm² ... 2.5 mm²
Stripping length 12 mm 8 mm
Ambient conditions
Ambient temperature (operation) -20 °C ... 65 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C
Conformance with EMC Directive 2004/108/EC
Noise immunity according to EN 61000-6-2
When being exposed to interference, there may be minimal deviations.
Noise emission according to EN 61000-6-4
Conformance / approvals
Conformance CE-compliant
ATEX II 3 G Ex nA IIC T4 Gc X
UL, USA / Canada UL 508 Recognized applied for
UL, USA / Canada Class I, Div. 2, Groups A, B, C, D T5 applied for
Shipbuilding GL applied for
MINI MCR-SL-PTB-FM
105449_en_00 PHOENIX CONTACT 5
5 Safety regulations and installation notes
5.1 Installation notes
The category 3 device is suitable for installation in the
zone 2 potentially explosive area. It fulfills the require-
ments of EN60079-0:2009 and EN60079-15:2010.
Installation, operation, and maintenance may only be car-
ried out by qualified electricians. Follow the installation in-
structions described. When installing and operating the
device, the applicable regulations and safety directives
(including national safety directives), as well as general
technical regulations, must be observed. The technical
data is provided in this package slip and on the certifi-
cates (conformity assessment, additional approvals
where applicable).
It is not permissible to open or modify the device. Do not
repair the device yourself but replace it with an equivalent
device. Repairs may only be carried out by the manufac-
turer. The manufacturer is not liable for damage resulting
from violation.
The IP20 degree of protection (IEC60529/EN60529) of
the device is intended for use in a clean and dry environ-
ment. Do not subject the device to any load that exceeds
the described limits.
The device is not designed for use in atmospheres with a
danger of dust explosions.
5.2 Installation in the Ex area (zone 2)
Observe the specified conditions for use in potentially ex-
plosive areas.
The device must be installed in a housing (control or dis-
tributor box) which meets the requirements of EN 60079-
15 and provides at least IP54 (EN 60529) degree of pro-
tection.
During installation and when connecting the supply and
signal circuits, observe the requirements of EN 60079-
14. Devices may only be connected to circuits in zone 2 if
they are suitable for operation in Ex zone 2 and for the
prevailing conditions at the place of use.
In potentially explosive areas, terminals may only be
snapped onto or off the DIN rail connector and wires may
only be connected or disconnected when the power is
switched off.
The device must be stopped and immediately removed
from the Ex area if it is damaged, has been subjected to
an impermissible load, has been stored incorrectly, or if it
malfunctions.
You can download the latest documents for these devic-
es from www.phoenixcontact.net/products.
MINI MCR-SL-PTB-FM
105449_en_00 PHOENIX CONTACT 6
6 Installation
6.1 Connection notes
6.2 Structure
Figure 1 Structure
1. Input: supply voltage 1 or fault monitoring output
2. Input: supply voltage 2 or fault monitoring output
3. Cover
4. Diagnostic LEDs 1 + 2: supply voltage connected with
reverse polarity
5. Diagnostic LEDs 3 + 4: supply voltage present
6. Groove for ZBF 6 zack marker strip
7. Input: supply voltage 1
8. Input: supply voltage 2
9. Connection for DIN rail connector
10. Universal snap-on foot for EN DIN rails
6.3 Block diagram
Figure 2 Block diagram
6.4 Power supply
6.5 Use in the MINI Analog system
Up to 80 MINI Analog modules are supplied at a supply
voltage of 18...30V DC.
In the event of a supply voltage below 18 V DC, the num-
ber of modules is reduced according to the increasing
current flow.
Up to 40 MINI Analog modules are supplied at a supply
voltage of 12 V DC (50 mA per device).
Wire the second input to provide redundancy.
NOTE: Electrostatic discharge!
The device contains components that can be
damaged or destroyed by electrostatic dis-
charge. When handling the device, observe the
necessary safety precautions against electro-
static discharge (ESD) according to EN 61340-
5-1 and EN 61340-5-2.
Serial No.
32825 Blomberg, Germany
MINI MCR–SL-PTB-FM
O
rd.
–No.: 29 02 95 8
www.phoenixcontact.com
Warning Do n ot seperate
when energized
II 3 G
Ex nA II C T4 Gc X
LED 2/1 rd: PWR1 / PWR2 Reverse polarity
L
E
D
4
/3
g
n
: P
W
R
1
O
K
/ P
W
R
2
O
K
OUT: 0...29,2VDC max. 2A
Power Terminal Block
T –20°...+65°C / –4°...+149°F
amb
P
W
R
1
IN
P
W
R
O
U
T
+
+
-
-
-
5
6
2
7
3
8
4
1
2
1
IN: 0...30VDC max. 2A
+
PWR 1
IN/ OUT-FM
PWR 2
IN/ OUT-FM
+
24V
+
24V
+2
4V
PWR 2
IN
+
-
+24V
+24V
4 3
+
-
O
U
T
F
M
9
1
8
7
3
4
10
2
5
6
NOTE: Never connect the supply voltage di-
rectly to the DIN rail connector. It is not permit-
ted to draw power from the DIN rail connector
or from individual modules.
Recommended fuse for power terminal
block:
Fuse in acc. with IEC 60127-2/V
Nominal current: 2.5 A
Characteristics: Slow-blow
(e.g. Wickmann 5 x 20 mm/No. 195 - glass
fuse)
NOTE
The total current in both supply paths must
not exceed 2A.
Connect at least one supply to the power termi-
nal in order to supply the DIN rail connector.
Zone 2
IN
PWR 1
IN
+24V
PWR 2
IN
+24V
+24V
PWR 2
IN / OUT-FM
+24V
PWR 1
IN / OUT-FM
IN
OUT FM
PWR OUT
1 5
2
6
7
8
3
4
+
+
+
+
+
4321
+24V

2902959

Mfr. #:
Manufacturer:
Phoenix Contact
Description:
Terminal Block Interface Modules MINI MCR-SL PTB-FM-SP
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet