Sub-Harmonic Pumped Mixer
14 - 32 GHz
Rev. V1
MAMX-011009
4
4
M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macomtech.com for additional data sheets and product information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
4
Typical Performance Curves for Down Conversion: T
A
= 25°C, RF = -10 dBm, LO = 15 dBm,
LO = 1/2x (RF+IF) GHz, IF = 2 GHz, Z
RF
=Z
LO
=Z
IF
= 50 Ω, unless noted
Isolation
Conversion Gain vs. RF Frequency
Input IP3 vs. RF Frequency (LO = +16 dBm)
LO Leakage
Conversion Gain vs. IF Frequency
Input IP3 vs. LO Drive Level
0
5
10
15
20
14 16 18 20 22 24 26 28 30 32
+25°C
-40°C
+85°C
RF Frequency (GHz)
-50
-40
-30
-20
-10
0
14 16 18 20 22 24 26 28 30 32
LO
2xLO
3xLO
RF Frequency (GHz)
0
5
10
15
20
14 16 18 20 22 24 26 28 30 32
12 dBm
14 dBm
16 dBm
RF Frequency (GHz)
0
20
40
60
80
14 16 18 20 22 24 26 28 30 32
RF to IF
LO to IF
2xLO to I F
3xLO to I F
RF Frequency (GHz)
-20
-15
-10
-5
0
14 16 18 20 22 24 26 28 30 32
+25°C
-40°C
+85°C
RF Frequency (GHz)
-20
-15
-10
-5
0
02468
16 GHz
24 GHz
32 GHz
IF Frequency (GHz)