Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
Pressure Sensor/PS(ADP4), PF(ADP1)
60
40
50
20
30
10
0
980.7/2{5} 980.7{10}
Pressure(kPa)
Output voltage (mV)
0
−3
−2
0
05×10
5
Pressure cycle(cycle)
Offset voltage range(%FS)
1×10
6
1
−1
3
2
4
3
2
1
0
−2
−1
30 86 60 1400 32
Temperature (°C °F)
Offset voltage-temperature characteristics (%FS)
4
3
2
1
0
−2
−1
Sensitivity-temperature characteristics(%FS)
30 86 60 1400 32
Temperature (°C °F)
−3
−2
0
05×10
5
Pressure cycle(cycle)
Output span voltage range(%FS)
1×10
6
1
−1
3
2
Rating
Reference Data
Type Standard type (With glass base)
Economy type
(Without glass base)
Type of pressure Gauge pressure
Pressure medium Air
✽2
Rated pressure (Unit: kPa) 4.9
34.3 to 343.2
490.3 833.6 980.7 98.1
✽3
980.7
✽3
40.0
Max. applied pressure Twice of the rated pressure
1.5 times of the
rated pressure
Twice of the
rated pressure
1.5 times of the
rated pressure
Twice of the
rated pressure
Bridge resistance 5,000 Ω ±1,000 Ω 3,300 Ω ±700 Ω 3,300 Ω ±600 Ω
Ambient temperature −20 °C to +100 °C
−4 °F to +212 °F (no freezing or condensation)
−5 °C to +50 °C
23 °F to +122 °F
Storage temperature −40 °C to +120 °C −40 °F to +248 °F (no freezing or condensation)
−20 °C to +70 °C
−4 °F to +158 °F
Standard temperature 25 °C 77 °F 30 °C 86 °F 25 °C 77 °F
Temperature compensation range
0 °C to 50 °C 32 °F to +122 °F
0 °C to 60 °C
32 °F to +140 °F
5 °C to 45 °C
41 °F to +113 °F
Drive current (constant current)
1.5 mA.DC 1.0 mA.DC 1.5 mA.DC
Output span voltage
40±20 mV
100±40 mV 65±25 mV 43.5±22.5 mV
Offset voltage ±20 mV ±15 mV
Linearity
±0.7 %FS
±0.3 %FS ±0.5 %FS ±0.6 %FS ±1.0 %FS ±0.3 %FS
Pressure hysteresis
±0.6 %FS
±0.2 %FS ±0.4 %FS ±1.0 %FS ±0.7 %FS
Offset voltage-temperature
characteristics
✽4
±15 %FS
±5.0 %FS ±3.5 %FS ±10 %FS
Sensitivity-temperature
characteristics
✽4
±10 %FS
±2.5 %FS ±1.3 %FS
Notes :
✽
1 Unless otherwise specifi ed, measurements were taken with a drive current of ±0.01 mA.DC and humidity ranging from 25% to 85%.
✽
2 Please consult us if a pressure medium other than air is to be used.
✽
3 For PS pressure sensor only
✽
4 This is the regulation which applies within the compensation temperature range.
✽
5 Please consult us if the intended use involves a negative pressure.
●
Characteristics data
●
Pressure cycle range (0 to rated pressure)
Even after testing for 1 million
times, the variations in the offset
voltage and output span voltage
are minimal.
1.-(1) Output characteristics
ADP41913
Drive current : 1.0 mA.DC ; temperature : 30 °C 86 °F
Tested sample : ADP41913, temperature : 100 °C 212 °F, No. of cycle: 1×10
6
Offset voltage range Output span voltage range
1.-(2) Offset voltage - temperature
characteristics
ADP41913
Drive current : 1.0 mA.DC; rating ±3.5 %FS
1.-(3) Sensitivity -temperature
characteristics
ADP41913
Drive current : 1.0 mA.DC; rating ±2.5 %FS
[PS pressure sensor]
Jul. 201500