3
Solder Reow Prole
Recommended reow condition as per JEDEC Standard, J-STD-020 (latest revision). Non-Halide Flux should be used.
Regulatory Information
ACPL-M62L is pending approval by the following organizations:
UL CSA IEC/EN/DIN EN 60747-5-5
UL 1577, component recognition
program up to V
ISO
= 3750 V
RMS
File
E55361.
Approved under CSA Component
Acceptance Notice #5, File CA 88324.
(Option 060E only)
Insulation and Safety Related Specications
Parameter Symbol ACPL-M62L Units Conditions
Minimum External Air Gap
(External Clearance)
L(101) 5 mm Measured from input terminals to output terminals,
shortest distance through air.
Minimum External Tracking
(External Creepage)
L(102) 5 mm Measured from input terminals to output terminals,
shortest distance path along body.
Minimum Internal Plastic Gap
(Internal Clearance)
0.08 mm Through insulation distance conductor to conductor, usually the
straight line distance thickness between the emitter and detector.
Tracking Resistance
(Comparative Tracking Index)
CTI 175 V DIN IEC 112/VDE 0303 Part 1
Isolation Group IIIa Material Group (DIN VDE 0110, 1/89, Table 1)
IEC/EN/DIN EN 60747-5-5 Insulation Characteristics* (Option 060E)
Description Symbol Characteristic Unit
Installation classication per DIN VDE 0110/39, Table 1
for rated mains voltage ≤ 150 V
rms
for rated mains voltage ≤ 300 V
rms
for rated mains voltage ≤ 600 V
rms
I – IV
I – IV
I – III
Climatic Classication 40/105/21
Pollution Degree (DIN VDE 0110/39) 2
Maximum Working Insulation Voltage V
IORM
567 V
peak
Input to Output Test Voltage, Method b*
V
IORM
× 1.875=V
PR
, 100% Production Test with t
m
=1 sec, Partial discharge < 5 pC V
PR
1063 V
peak
Input to Output Test Voltage, Method a*
V
IORM
× 1.6=V
PR
, Type and Sample Test, t
m
=10 sec, Partial discharge < 5 pC V
PR
907 V
peak
Highest Allowable Overvoltage
(Transient Overvoltage t
ini
= 60 sec) V
IOTM
6000 V
peak
Safety-limiting values – maximum values allowed in the event of a failure
Case Temperature
Input Current
Output Power
T
S
I
S, INPUT
P
S, OUTPUT
150
150
600
°C
mA
mW
Insulation Resistance at T
S
, V
IO
= 500 V R
S
>10
9
Ω
* Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section, (IEC/EN/DIN
EN 60747-5-5) for a detailed description of Method a and Method b partial discharge test proles.