NCP1380
www.onsemi.com
8
ELECTRICAL CHARACTERISTICS (continued) (Unless otherwise noted: For typical values T
J
= 25°C, V
CC
= 12 V, V
ZCD
= 0 V,
V
FB
= 3 V, V
CS
= 0 V, V
fault
= 1.5 V, C
T
= 680 pF) For min/max values T
J
= −40°C to +125°C, Max T
J
= 150°C, V
CC
= 12 V)
Symbol UnitMaxTypMinCondition
FEEDBACK SECTION
V
H2D
V
H3D
V
H4D
V
HVCOD
V
HVCOI
V
H4I
V
H3I
V
H2I
Valley threshold
FB voltage where 1
st
valley ends and 2
nd
valley
starts
FB voltage where 2
nd
valley ends and 3
rd
valley
starts
FB voltage where 3
rd
valley ends and 4
th
valley
starts
FB voltage where 4
th
valley ends and VCO starts
FB voltage where VCO ends and 4
th
valley starts
FB voltage where 4
th
valley ends and 3
rd
valley
starts
FB voltage where 3
rd
valley ends and 2
nd
valley
starts
FB voltage where 2
nd
valley ends and 1
st
valley
starts
V
FB
decreases
V
FB
decreases
V
FB
decreases
V
FB
decreases
V
FB
increases
V
FB
increases
V
FB
increases
V
FB
increases
1.316
1.128
0.846
0.732
1.316
1.504
1.692
1.880
1.4
1.2
0.9
0.8
1.4
1.6
1.8
2.0
1.484
1.272
0.954
0.828
1.484
1.696
1.908
2.120
V
FAULT PROTECTION (ALL VERSIONS)
T
SHDN
Thermal Shutdown Device switching (F
SW
around 65 kHz)
140 − 170 °C
T
SHDN(HYS)
Thermal Shutdown Hysteresis − 40 − °C
t
OVLD
Overload Timer V
FB
= 4 V, V
CS
> V
ILIM
75 85 95 ms
t
SSTART
Soft−start duration V
FB
= 4 V, V
CS
ramping up,
measured from 1
st
DRV
pulse to V
CS(peak)
= 90% of
V
ILIM
2.8 3.8 4.8 ms
R
Fault(clamp)
Clamp series resistor 1.3 1.55 1.8
kW
V
OVP
Fault detection level for OVP V
Fault
increasing 2.35 2.5 2.65 V
t
latch(delay)
Delay before latch confirmation 22.5 30 37.5
ms
FAULT PROTECTION A & B VERSIONS
I
OTP(REF)
Reference current for direct connection of an
NTC (Note 7)
V
Fault
= V
OTP
+ 0.2 V 85 91 97
mA
V
OTP
Fault detection level for OTP V
Fault
decreasing 0.744 0.8 0.856 V
V
Fault(clamp)
Clamped voltage (Fault pin left open) Fault pin open 1.13 1.35 1.57 V
FAULT PROTECTION C & D VERSIONS
V
BO
Brown−Out level V
Fault
decreasing 0.744 0.8 0.856 V
I
BO
Sourced hysteresis current V
Fault
> V
BO
V
Fault
= V
BO
+ 0.2 V 9 10 11
mA
t
BO(delay)
Delay before entering and exiting Brown−out 22.5 30 37.5
ms
V
Fault(clamp)
Clamped voltage (Fault pin left open) Fault pin open 1.0 1.2 1.4 V
Product parametric performance is indicated in the Electrical Characteristics for the listed test conditions, unless otherwise noted. Product
performance may not be indicated by the Electrical Characteristics if operated under different conditions.
3. Guaranteed by design.
4. The peak current setpoint goes down as the load decreases. It is frozen below I
peak(VCO)
(I
peak
= cst)
5. If negative voltage in excess to −300 mV is applied to ZCD pin, the current setpoint decrease is no longer guaranteed to be linear
6. Minimum value for T
J
= 125°C
7. NTC with R
110
= 8.8 kW.