IEC/EN/DIN EN 60747-5-2 Insulation Characteristics
(1)
Description Symbol Characteristic Unit
Installation classification per DIN VDE 0110/1.89, Table 1
For rated mains voltage ≤ 150 Vrms
For rated mains voltage ≤ 300 Vrms
For rated mains voltage ≤ 600 Vrms
I – IV
I – III
I – II
Climatic Classification 55/100/21
Pollution Degree (DIN VDE 0110/1.89) 2
Maximum Working Insulation Voltage V
IORM
891 V
PEAK
Input to Output Test Voltage, Method b
(2)
V
IORM
x 1.875 = V
PR
, 100% Production Test with t
m
= 1 sec,
Partial Discharge < 5 pC
V
PR
1670 V
PEAK
Input to Output Test Voltage, Method a
(2)
V
IORM
x 1.5 = V
PR
, Type and Sample Test, t
m
= 60 sec,
Partial Discharge < 5 pC
V
PR
1336 V
PEAK
Highest Allowable Over-voltage
(2)
(Transient Over-voltage tini = 10 sec)
Safety-limiting values - maximum values allowed in the event of a failure
Case Temperature
Control Side Power
(3)
Line Side Power
(3)
V
IOTM
T
S
P
S, INPUT
P
S, OUTPUT
6000
175
400
1500
V
PEAK
°C
mW
mW
Insulation Resistance at T
S
, V
IO
= 500 V R
S
>10
9
Ω
Notes:
1. Isolation characteristics are guaranteed only within the safety
maximum ratings that must be ensured by protective circuits in
application. Surface mount classification is class A in accordance
with CECCOO802.
2. Refer to the optocoupler section of the Isolation and Control
Component Designer’s Catalog, under Product Safety Regulations
section, (IEC/EN/DIN EN 60747-5-2) for a detailed description of
Method a and Method b partial discharge test profiles.
3. Refer to the following figure for dependence of PS, INPUT and PS,
OUTPUT on case temperature.
0 25 50 75 100 125 150 175 200
1600
1400
1200
1000
800
600
400
200
0
T
S
– CASE TEMPERATURE – °C
P
S
– POWER – mW
P
S, OUTPUT
P
S, INPUT
0 25 50 75 100 125 150 175 200
1600
1400
1200
1000
800
600
400
200
0
T
S
– CASE TEMPERATURE – °C
P
S
– POWER – mW
P
S, OUTPUT
P
S, INPUT
Regulatory Information
The HCPL-800J is pending for approval by the following organizations:
IEC/EN/DIN EN 60747-5-2
Approved under:
IEC 60747-5-2:1997 + A1:2002
EN 60747-5-2:2001 + A1:2002
DIN EN 60747-5-2 (VDE 0884 Teil 2):2003-01
with VIORM = 891 Vpeak.
UL
Recognized under UL 1577,
component recognition program, File E55361.
CSA
Approved under CSA
Acceptance Notice #5,
File CA 88324.