4
Package Characteristics
All specifications and figures are at the nominal (typical) operating conditions of V
CC1
= 5 V, GND1 = 0 V, V
CC2
= 5 V,
GND2 = 0 V and T
A
= +25°C.
Parameter Symbol Min. Typ. Max. Units Test Conditions Note
Control IC - Line IC Momentary
Withstand Voltage
V
ISO
3750 V
rms
RH< 50%, t = 1 min.,
T
A
= 25°C
1, 2, 3
Resistance (Control IC - Line IC) R
I-O
>109
V
I-O
= 500 Vdc 3
Capacitance (Control IC - Line IC) C
I-O
1.4 pF f = 1 MHz
Control IC to Ambient Thermal
Resistance
θ
IA
83 °C/W 1 oz. trace, 2-layer PCB
Still air, T
A
= 25°C
4
Line IC to Ambient Thermal
Resistance
θ
OA
85
Notes:
1. In accordance with UL1577, each optocoupler is proof tested by applying an insulation test voltage 4500 Vrms for 1 second (leakage
detection current limit, I
I-O
5 µA). This test is performed before the 100% production test for partial discharge (method b) shown in IEC/EN/
DIN EN 60747-5-2 Insulation Characteristics Table, if applicable.
2. The Control IC-Line IC Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as a Control IC-Line IC
continuous voltage rating. For the continuous voltage rating refer to your equipment level safety specification or IEC/EN/DIN EN 60747-5-2
Insulation Characteristics Table.
3. Device is considered as a two terminal device: pins 1 - 8 shorted together and pins 9 - 16 shorted together.
4. Maximum power dissipation in Control side and Line side IC’s needs to be limited to ensure that their respective junction temperature is less
than 125°C. The maximum permissible power dissipation is dependent on the thermal impedance and the ambient temperature. Details on
the typical thermal impedances are given in the Package Characteristics. Further details on applying this to an actual application can be found
in the Application Information section under Thermal Considerations.
Recommended PB-free IR Profile
Note: Non-halide flux should be used
30 seconds
60 ~ 150 sec 90 sec 60 sec
60 sec
25°C
150
°
C
200
°C
250
°C
260°C (Peak Temperature)
217
°C
Time (sec)
Temperature (
°
C)
5
IEC/EN/DIN EN 60747-5-2 Insulation Characteristics
(1)
Description Symbol Characteristic Unit
Installation classification per DIN VDE 0110/1.89, Table 1
For rated mains voltage 150 Vrms
For rated mains voltage 300 Vrms
For rated mains voltage 600 Vrms
I – IV
I – III
I – II
Climatic Classification 55/100/21
Pollution Degree (DIN VDE 0110/1.89) 2
Maximum Working Insulation Voltage V
IORM
891 V
PEAK
Input to Output Test Voltage, Method b
(2)
V
IORM
x 1.875 = V
PR
, 100% Production Test with t
m
= 1 sec,
Partial Discharge < 5 pC
V
PR
1670 V
PEAK
Input to Output Test Voltage, Method a
(2)
V
IORM
x 1.5 = V
PR
, Type and Sample Test, t
m
= 60 sec,
Partial Discharge < 5 pC
V
PR
1336 V
PEAK
Highest Allowable Over-voltage
(2)
(Transient Over-voltage tini = 10 sec)
Safety-limiting values - maximum values allowed in the event of a failure
Case Temperature
Control Side Power
(3)
Line Side Power
(3)
V
IOTM
T
S
P
S, INPUT
P
S, OUTPUT
6000
175
400
1500
V
PEAK
°C
mW
mW
Insulation Resistance at T
S
, V
IO
= 500 V R
S
>10
9
Notes:
1. Isolation characteristics are guaranteed only within the safety
maximum ratings that must be ensured by protective circuits in
application. Surface mount classification is class A in accordance
with CECCOO802.
2. Refer to the optocoupler section of the Isolation and Control
Component Designer’s Catalog, under Product Safety Regulations
section, (IEC/EN/DIN EN 60747-5-2) for a detailed description of
Method a and Method b partial discharge test profiles.
3. Refer to the following figure for dependence of PS, INPUT and PS,
OUTPUT on case temperature.
0 25 50 75 100 125 150 175 200
1600
1400
1200
1000
800
600
400
200
0
T
S
– CASE TEMPERATURE – °C
P
S
– POWER – mW
P
S, OUTPUT
P
S, INPUT
0 25 50 75 100 125 150 175 200
1600
1400
1200
1000
800
600
400
200
0
T
S
– CASE TEMPERATURE – °C
P
S
– POWER – mW
P
S, OUTPUT
P
S, INPUT
Regulatory Information
The HCPL-800J is pending for approval by the following organizations:
IEC/EN/DIN EN 60747-5-2
Approved under:
IEC 60747-5-2:1997 + A1:2002
EN 60747-5-2:2001 + A1:2002
DIN EN 60747-5-2 (VDE 0884 Teil 2):2003-01
with VIORM = 891 Vpeak.
UL
Recognized under UL 1577,
component recognition program, File E55361.
CSA
Approved under CSA
Acceptance Notice #5,
File CA 88324.
6
Insulation and Safety Related Specifications
Parameter Symbol Value Unit Condition
Minimum External Air Gap
(Clearance)
L(101) 8.3 mm Measured from input terminals to output terminals, short-
est distance through air.
Minimum External Tracking
(Creepage)
L(102) 8.3 mm Measured from input terminals to output terminals, short-
est distance path along body.
Minimum Internal Plastic Gap
(Internal Clearance)
0.5 mm Through insulation distance of conductor to conductor,
usually the straight-line distance between the emitter and
detector.
Tracking Resistance
(Comparative Tracking Index)
CTI >175 Volts DIN IEC 112/VDE 0303 Part 1
Isolation Group IIIa Material Group (DIN VDE 0110, 1/89, Table 1)
Absolute Maximum Ratings
Parameter Symbol Minimum Maximum Unit Note
Storage Temperature T
S
-55 125 °C
Ambient Operating Temperature T
A
-40 85 °C
Junction Temperature T
J
125 °C
Supply Voltage 1 V
CC1
-0.5 5.5 V
Supply Voltage 2 V
CC2
-0.5 5.5 V
Transmit Output Voltage V
Tx-out
-0.5 V
CC2
V
Transmit Input Signal Voltage V
Tx-in
-0.5 V
CC1
V
Transmit Enable Voltage V
Tx-en
-0.5 V
CC1
V
Receiving Input Signal Voltage V
Rx-in
-0.5 V
CC2
V
Control-Side Power Dissipation P
I
200 mW 1
Line-Side Power Dissipation P
O
1000 mW
Solder Reflow Temperature Profile (See Solder Reflow Temperature Profile Section)
Notes:
1. Maximum power dissipation in Control side and Line side IC’s needs to be limited to ensure that their respective junction temperature is less
than 125°C. The maximum permissible power dissipation is dependent on the thermal impedance and the ambient temperature. Details on
the typical thermal impedances are given in the Package Characteristics. Further details on applying this to an actual application can be found
in the Application Information section under Thermal Considerations.
Recommended Operating Conditions
Parameter Symbol Minimum Typical Maximum Unit Note
Ambient Operating Temperature T
A
-40 85 °C
Input Supply Voltage V
CC1
4.75 5 5.25 V
Output Supply Voltage V
CC2
4.75 5 5.25 V
Tx-in Signal Current I
Tx-in
250 µA
PP
1
Notes:
1. The transmitter input impedance is very low, this is meant for signal current input. Transmitter performance is optimized at 250 µAPP input
signal, an external series resistor with nominal value of 2 k would be required if the input signal is 0.5 V
PP
.

HCPL-800J-500E

Mfr. #:
Manufacturer:
Broadcom / Avago
Description:
Buffers & Line Drivers PLC Powerline DAA IC
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet