LT1610
E
LECTR
IC
AL C CHARA TERIST
ICS
The ● denotes specifications which apply over the specified temperature
range, otherwise specifications are at T
A
= 25°C. Commercial grade 0°C to 70°C, V
IN
= 1.5V, V
SHDN
= V
IN
, unless otherwise noted.
(Note 2)
PARAMETER CONDITIONS MIN TYP MAX UNITS
Switch Current Limit (Note 3) 450 600 900 mA
Switch V
CESAT
I
SW
= 300mA 300 350 mV
● 400 mV
Switch Leakage Current V
SW
= 5V 0.01 1 µA
SHDN Input Voltage High 1V
SHDN Input Voltage Low 0.3 V
SHDN Pin Bias Current V
SHDN
= 3V 10 µA
V
SHDN
= 0V 0.01 0.1 µA
The ● denotes specifications which apply over the specified temperature range, otherwise specifications are at T
A
= 25°C.
Industrial grade –40°C to 85°C, V
IN
= 1.5V, V
SHDN
= V
IN
, unless otherwise noted.
PARAMETER CONDITIONS MIN TYP MAX UNITS
Minimum Operating Voltage T
A
= 85°C 0.9 1 V
T
A
= –40°C 1.25 V
Maximum Operating Voltage 8V
Feedback Voltage ● 1.20 1.23 1.26 V
Quiescent Current 30 60 µA
Quiescent Current in Shutdown V
SHDN
= 0V, V
IN
= 2V 0.01 0.5 µA
V
SHDN
= 0V, V
IN
= 5V 0.01 1.0 µA
FB Pin Bias Current ● 27 80 nA
Reference Line Regulation 2V ≤ V
IN
≤ 8V (–40°C) 0.03 0.15 %/V
2V ≤ V
IN
≤ 8V (85°C) 0.2 %/V
Error Amp Transconductance ∆I = 2µA25µmhos
Error Amp Voltage Gain 100 V/V
Switching Frequency (Note 4) ● 1.4 1.7 2 MHz
Maximum Duty Cycle (Note 4) 77 80 95 %
● 75 95 %
Switch Current Limit 450 600 900 mA
Switch V
CESAT
I
SW
= 300mA 300 350 mV
● 400 mV
Switch Leakage Current V
SW
= 5V 0.01 1 µA
SHDN Input Voltage High 1V
SHDN Input Voltage Low 0.3 V
SHDN Pin Bias Current V
SHDN
= 3V 10 µA
V
SHDN
= 0V 0.01 0.1 µA
Note 1: Absolute Maximum Ratings are those values beyond which the life
of a device may be impaired.
Note 2: The LT1610C is guaranteed to meet specified performance from
0°C to 70°C and is designed, characterized and expected to meet these
extended temperature limits, but is not tested at –40°C and 85°C. The
LT1610I is guaranteed to meet the extended temperature limits.
Note 3: Current limit guaranteed by design and/or correlation to static test.
Current limit is affected by duty cycle due to ramp generator. See Block
Diagram.
Note 4: Not 100% tested at 85°C.