PM4H-A
Type
Item
PM4H-S
100 to 240V AC, 48 to 125V DC, 12V DC, 24V AC/DCRated operating voltage
50/60Hz common (AC operating type)
5A 250V AC (resistive load)
Power ON-delay
Pulse ON-delay
Pulse Flicker
Pulse ON-Flicker
Differential ON/OFF-delay (1) (2)
Signal OFF-delay
Pulse One-shot
Pulse One-cycle
Power ON-delay
Power Flicker
Power ON-flicker
Power One-shot
Power One-cycle
(with instantaneous contact)
Rated frequency
Rated control capacity
1s to 500h (Max.) 16 time ranges switchable
±0.3% (power off time change at the range of 0.1s to 1h)
±5% (Full-scale value)
±0.5% (at the operating voltage changes between 85 to 110%)
Max. 100mΩ (at 1A 6V DC)
±2% (at 20°C ambient temp. at the range of –10 to +50°C +14 to +122°F)
Timed-out 1 Form C
Instantaneous 1 Form C
Time range
Operating time fluctuation
2×10
7
10
5
(at rated control capacity)
Mechanical (contact)
Electrical (contact)
85 to 110% of rated operating voltage (at 20°C coil temp.)Allowable operating voltage range
–10 to +50°C +14 to +122°FAmbient temperature
30 to 85%RH (at 20°C 68°F, non-condensing)Ambient humidity
860 to 1,060hPaAtmospheric pressure
20%Ripple factor (DC type)
IP65 on front panel (using rubber gasket ATC18002) <only for IP65 type>Protective construction
100g 3.527 oz (Pin type)
110g 3.880 oz (Screw terminal type)
Weight
10 to 55Hz: 1 cycle/min double amplitude of 0.25mm (10min on 3 axes)
Vibration resistance
10 to 55Hz: 1 cycle/min double amplitude of 0.375mm (1h on 3 axes)
Min. 98m/s
2
(4 times on 3 axes)
Shock resistance
Min. 980m/s
2
(5 times on 3 axes)
Functional
Destructive
Functional
Destructive
Between live and dead metal parts
Between input and output
Between contacts of different poles
Between contacts of same pole
Insulation resistance (Initial value)
2,000Vrms for 1 min Between live and dead metal parts
2,000Vrms for 1 min Between input and output
2,000Vrms for 1 min Between contacts of different poles
1,000Vrms for 1 min Between contacts of same pole
Breakdown voltage (Initial value)
Setting error
Voltage error
Contact resistance (Initial value)
100msMin. power off time
55°C 131°F 65°C 149°FMax. temperature rise
Silver alloy Au flash on Silver alloyContact material
Temperature error
Timed-out 2 Form CContact arrangement
Operating mode
Approx. 10VA (100 to 240V AC)
Approx. 2.5VA (24V AC)
Approx. 1.5W (12V DC, 24V DC, 48 to 125V DC)
Rated power consumption
Rating
Time
accuracy
Note:)
Contact
Life
Electrical
function
Mechanical
function
Operating
condition
Others
PM4H-M
Min. 100MΩ (At 500V DC)
Note: 1) Unless otherwise specified, the measurement conditions at the maximum scale time standard are specified to be the rated operating voltage (within 5% ripple
factor for DC), 20°C 68°F ambient temperature, and 1s power off time.
2) For the 1s range, the tolerance for each specification becomes ±10ms.
PM4H-A/S/M
PM4H-A/PM4H-S/PM4H-M
All types of PM4H timer have multi-time
range.
16 time ranges are selectable.
1s to 500h (Max. range) is controlled.
Time range