PM4HA-H-AC240V

PM4H-A/S/M
Dimensions
mm inch
Tolerance: ±0.5 ±.020
PM4H-
Screw terminal type
(Flush mount)
Panel mount dimensions (with mounting frame)
Screw terminal type
Surface mount dimensions
Pin type
Panel cut out dimensions
Standard cut out dimensions are shown
below.
Use mounting frame (AT8-DA4) and rubber
gasket (ATC18002).
Adjacent mounting
Pin type
Pin type
(Flush mount/Surface mount)
Note) 1. The proper thickness of mounting
panel is between 1 to 5mm.
2. Adjacent mount is less water-resis-
tant.
62.5
2.461
12.0
.472
.236
6.0
48
1.890
48
1.890
44.5
1.752
41 dia.
1.614 dia.
1
.039
48
1.890
61.5
2.421
48
1.890
44.5
1.752
50
1.969
66
2.598
Rubber gasket
ATC 18002 (attached)
Mounting frame
AT8-DA4 (attached)
Panel
48
1.890
48
1.890
50
1.969
66
2.598
72.5 2.854 (8-pin)
78 3.071 (11-pin)
Rubber gasket
ATC18002
Mounting frame
AT8-DA4
(Sold separately)
Rear terminal socket
AT78041 (8-pin: sold separately)
AT78051 (11-pin: sold separately)
Panel
Din rail socket
AT8-DF8K
(8-pin: sold separately)
AT8-DF11K
(11-pin: sold separately)
Mounting rail
AT8-DLA1
104.0 (11-pin)
4.094
97.3 (8-pin)
3.831
45
+
1.772
+.024
0
0.6
0
45
+
1.772
+.024
0
0.6
0
Min. 80
3.150
Min. 80 3.150
A
45
+
1.772
+.024
0
0.6
0
A = (48×n–2.5)
+
A = (1.890×n–.098)
+.024
0
0.6
0
14.5
66.5
2.618
48
1.890
44.5
1.752
41 dia.
1.614 dia.
48
1.890
12.0
.472
.236
6.0
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
PM4H-A/S/M
Operation mode
PM4H-A
Note: Keep 0.1s or more for power off time.
Keep 0.05s or more for start, stop, reset input time.
Operation type Explanation Time chart
• If using a time-limit start when the power is turned on, and a reset when
the power is turned off, pins 2 to 6 (screw-tightening pins x and c)
should be shorted ahead of time.
• Turn the operation mode selector switch to the position.
If pins 2 to 6 (screw-tightening pins x and c) are shorted (the start input
is turned on) with the power supply on, the output will go on after the set
time has elapsed.
If the power supply is turned off, or pins 2 to 7 (screw-tightening pins x to
v) are shorted (the reset input is turned on), a reset is carried out.
Note) During time-limited operation, the time-limited operation is stopped
while the pins 2 to 5 (screw-tightening pins x to b) are being shorted
(the stop input is on). When the pins are released, time-limited operation
resumes.
• Turn the operation mode selector switch to the position.
When pins 2 to 6 (screw-tightening pins x and c) are shorted (the start
input is turned on) with the power supply on, the output goes on, and when
pins 2 to 6 (screw-tightening pins x and c) are released (the start input
is turned off), the time limit interval begins. After the set time has elapsed,
the output goes off. If start input is entered at any point during the time limit
interval, the time limit interval is reset.
Note) During time-limited operation, the time-limited operation is stopped
while the pins 2 to 5 (screw-tightening pins x to b) are being shorted
(the stop input is on). When the pins are released, time-limited operation
resumes.
• Turn the operation mode selector switch to the position.
When pins 2 to 6 (screw-tightening pins x and c) are shorted (the start
input is turned on) with the power supply on, the output goes on, and after
the set time has elapsed, it goes off.
Also, when pins 2 to 6 are released (the start input goes off), the output
goes on, and after the set time has elapsed, it goes off.
If the status of pins 2 to 6 (screw-tightening pins x and c) changes dur-
ing the time-limit interval (the start input goes from on to off, or from off to
on), the time-limit interval is restarted from the point at which the change
took place.
If the power supply is turned off, or pins 2 to 7 (screw-tightening pins x to
v) are shorted (the reset input is turned on), a reset is carried out.
Note) During time-limited operation, the time-limited operation is stopped while
the pins 2 to 5 (screw-tightening pins x to b) are being shorted (the stop
input is on). When the pins are released, time-limited operation resumes.
• If using a time-limit start when the power is turned on, and a reset when
the power is turned off, pins 2 to 6 (screw-tightening pins x and c)
should be shorted ahead of time.
• Turn the operation mode selector switch to the position.
When pins 2 to 6 (screw-tightening pins x and c) are shorted (the start
input is turned on) with the power supply on, the output goes on, and after
the set time has elapsed, it goes off. This process is subsequently repeated.
If the power supply is turned off, or pins 2 to 7 (screw-tightening pins x to
v) are shorted (the reset input is turned on), a reset is carried out.
Note) During time-limited operation, the time-limited operation is stopped
while the pins 2 to 5 (screw-tightening pins x to b) are being shorted
(the stop input is on). When the pins are released, time-limited operation
resumes.
• If using a time-limit start when the power is turned on, and a reset when
the power is turned off, pins 2 to 6 (screw-tightening pins x and c)
should be shorted ahead of time.
• Turn the operation mode selector switch to the position.
When pins 2 to 6 (screw-tightening pins x and c) are shorted (the start
input is turned on) with the power supply on, the limited time interval begins,
and the output goes on after the set time has elapsed. After the output has
gone on, it goes off when the set time has elapsed, and this process is sub-
sequently repeated.
If the power supply is turned off, or pins 2 to 7 (screw-tightening pins x to
v) are shorted (the reset input is turned on), a reset is carried out.
Note) During time-limited operation, the time-limited operation is stopped
while the pins 2 to 5 (screw-tightening pins x to b) are being shorted
(the stop input is on). When the pins are released, time-limited operation
resumes.
Pulse
ON-delay
ON
ON
Pulse
Flicker
FL
FL
Pulse
ON-flicker
FO
FO
Differential
ON/OFF-delay (1)
OF1
OF1
Signal
OFF-delay
SF
SF
Power supply
ON
OFF
Start
ON
OFF
ON ON
OFF
Reset
ON
OFF
Stop
ON
OFF
Time out (N.O. contact)
OP. LED
POWER LED
ON
Tt1 t2
ON
OFFOFF
Note: LED lighting or No LED lighting
Power supply
ON
OFF
Start
ON
OFF
ON
OFF
ON
OFF
OFF
Reset
ON
Stop
ON
OFF
Time out (N.O. contact)
OP. LED
POWER LED
ON
TT t1ta t2 tb
ON
OFFOFF
Note: LED lighting or No LED lighting
Power supply
ON
OFF
Start
ON
OFF
ON
OFF
ON
OFF
OFF
Reset
ON
Stop
ON
OFF
Time out (N.O. contact)
OP. LED
POWER LED
ON
TT t2 Tta tbt1
OFFOFF
Power supply
ON
OFF
Start
ON
OFF
ON
OFF
ON
Reset
Stop
ON
OFF
Time out (N.O. contact)
OP. LED
POWER LED
ON ON
Tt1 t2 ta tb
OFF OFF
ON
OFF
Restart
OFF
Note: LED lighting or No LED lighting
Power supply
ON
OFF
Start
ON
OFF
ON
OFF
ON
OFF
ON
Reset
Stop
Time out (N.O. contact)
OP. LED
POWER LED
ON
Ttbta
OFF
OFF
Note: LED lighting or No LED lighting
LED lighting LED flickering
T: Setting time t
1, t2, ta, tb<T t1+t2=T
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
PM4H-A/S/M
Note: Keep 0.1s or more for power off time.
Keep 0.05s or more for start, stop, reset input time.
Operation type Explanation Time chart
• If using a time-limit start when the power is turned on, and a reset when
the power is turned off, pins 2 to 6 (screw-tightening pins x and c)
should be shorted ahead of time.
• Turn the operation mode selector switch to the position.
When pins 2 to 6 (screw-tightening pins x and c) are shorted (the start
input is turned on) with the power supply on, the output goes on for the set
time limit interval.
If the power supply is turned off, or pins 2 to 7 (screw-tightening pins x to
v) are shorted (the reset input is turned on), a reset is carried out.
Note) During time-limited operation, the time-limited operation is stopped
while the pins 2 to 5 (screw-tightening pins x to b) are being shorted
(the stop input is on). When the pins are released, time-limited operation
resumes.
• If using a time-limit start when the power is turned on, and a reset when
the power is turned off, pins 2 to 6 (screw-tightening pins x and c)
should be shorted ahead of time.
• Turn the operation mode selector switch to the position.
When pins 2 to 6 (screw-tightening pins x and c) are shorted (the start
input is turned on) with the power supply on, the output goes on after the
set time limit interval has elapsed. After it has gone on, it goes off after
one pulse (approximately 0.8 seconds).
If the power supply is turned off, or pins 2 to 7 (screw-tightening pins x
to v) are shorted (the reset input is turned on), a reset is carried out.
Note) During time-limited operation, the time-limited operation is stopped
while the pins
2 to 5
(screw-tightening pins
x to b
) are being shorted
(the stop input is on). When the pins are released, time-limited operation
resumes.
• Turn the operation mode selector switch to the position.
When pins 2 to 6 (screw-tightening pins x and c) are shorted (the start
input is turned on) with the power supply on, the time limit interval begins,
and after the set time interval has elapsed, the output goes on.
Also, when pins 2 to 6 are released (the start input goes off), the time limit
interval begins, and after it has elapsed, the output goes off.
If the status of pins 2 to 6 (screw-tightening pins x and c) changes dur-
ing the time-limit interval (the start input goes from on to off, or from off to
on), the time limit interval is restarted from the point at which the change
took place.
If the power supply is turned off, or pins 2 to 7 (screw-tightening pins x to
v) are shorted (the reset input is turned on), a reset is carried out.
Note) During time-limited operation, the time-limited operation is stopped while
the pins 2 to 5 (screw-tightening pins x to b) are being shorted (the stop
input is on). When the pins are released, time-limited operation resumes.
Pulse
One-shot
OS
OS
Differential
ON/OFF-delay (2)
OF2
OF2
Pulse
One-cycle
OC
OC
PM4H-S
PM4H-M
Operation type Explanation Time chart
Time limit contact relay
When the power supply is turned on, the output goes on after the set
time interval has elapsed.
When the power supply is turned off, a reset is carried out.
Power ON-delay
Note: Keep 0.1s or more for power off time. PM4H-M timers do not have each input which is start, reset and stop.
Operation type Explanation Time chart
Turn the operation mode selector switch to display the various opera-
tions.
When the power supply is turned on, the time limit interval begins,
and operation is carried out.
When the power supply is turned off, a reset is carried out.
Power ON-delay
ON
Power Flicker
FL
Power ON-flicker
FO
Power One-shot
OS
Power One-cycle
OC
Power supply
ON
OFF
Start
ON
OFF OFF
ON
ON
OFF
ON
Reset
Stop
Time out (N.O. contact)
OP. LED
POWER LED
ON
TT t
at1 t2
OFF
OFF
Note: LED lighting or No LED lighting
Power supply
ON
OFF
Start
ON
OFF
ON
OFF
ON
OFF
OFF
ON
Reset
Stop
Time out (N.O. contact)
OP. LED
POWER LED
ON ON
Ttbt1 t2 ta
OFF
OFF
Restart
Note: LED lighting or No LED lighting
Power supply
ON
OFF
Start
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Reset
Stop
Time out (N.O. contact)
OP. LED
POWER LED
Tta
ON
OFF
ON
OFF
ON
OFF
tt1 tbt2 t
OFF
One pulse time (t): Approx. 0.8s
Note: LED lighting or No LED lighting
ON
Power supply
ON
OFF
ON
OFF
Time out (N.O. contact)
OP. LED
POWER LED
T
Power supply
ON
OFF
ON
OFF
ON
OFF
Instantaneous contact (N.O. contact)
Time out (N.O. contact)
Power ON-delay
OP. LED
POWER LED
T
LED lighting LED flickering
T: Setting time
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.

PM4HA-H-AC240V

Mfr. #:
Manufacturer:
Panasonic
Description:
RELAY TIME DELAY 500HRS 5A 250V
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union