21
FN8114.2
August 25, 2008
V
TRIPX
Set/Reset Conditions
SCL
SDA
V
CC
/V2MON/V3MON
(V
TRIPX
)
WDO
t
TSU
t
THD
t
VPH
t
VPS
V
P
t
WC
t
VPO
A0h
0
7
70 7
0DH*
SETS V
TRIP1
SETS V
TRIP2
SETS V
TRIP3
01H*
09H*
03H*
0BH*
0FH*
RESETS V
TRIP3
RESETS V
TRIP2
RESETS V
TRIP1
0
START
* ALL OTHERS RESERVED
00h
*
VTRIP1, VTRIP2, VTRIP3 Programming Specifications V
CC
= 2.0V to 5.5V; Temperature = +25°C
PARAMETER DESCRIPTION
MIN
(Note 3)
MAX
(Note 3) UNIT
t
VPS
WDO Program Voltage Setup Time 10 µs
t
VPH
WDO Program Voltage Hold Time 10 µs
t
TSU
V
TRIPx
Level Setup Time 10 µs
t
THD
V
TRIPx
Level Hold (stable) Time 10 µs
t
WC
V
TRIPx
Program Cycle 10 ms
t
VPO
Program Voltage Off Time Before Next Cycle 1 ms
V
P
Programming Voltage 15 18 V
V
TRAN1
V
TRIP1
Set Voltage Range 2.0 4.75 V
V
TRAN2
V
TRIP2
Set Voltage Range - X40030, X40031 1.7 4.75 V
V
TRAN2A
V
TRIP2
Set Voltage Range - X40034, X40035 0.9 3.5 V
V
TRAN3
V
TRIP3
Set Voltage Range 1.7 4.75 V
V
tv
V
TRIPx
Set Voltage Variation After Programming (-40 to +85°C). -25 +25 mV
t
VPS
WDO Program Voltage Setup Time 10 µs
X40030, X40031, X40034, X40035