TLP185
4 2017-04-27
Electrical Characteristics
(Ta = 25°C)
Characteristic Symbol Test Condition Min Typ. Max Unit
LED
Forward voltage V
F
I
F
= 10 mA 1.1 1.25 1.4 V
Reverse current I
R
V
R
= 5 V — — 5 μA
Capacitance C
T
V = 0 V, f = 1 MHz — 30 — pF
Detector
Collector-emitter breakdown voltage V
(BR)CEO
I
C
= 0.5 mA 80 — — V
Emitter-collector breakdown voltage V
(BR)ECO
I
E
= 0.1 mA 7 — — V
Collector dark current I
CEO
V
CE
= 48 V — 0.01 0.08 μA
V
CE
= 48 V, Ta = 85°C — 2 50 μA
Capacitance (collector to emitter) C
CE
V = 0 V, f = 1 MHz — 10 — pF
Coupled Electrical Characteristics
(Ta = 25°C)
Characteristic Symbol Test Condition Min Typ. Max Unit
Current transfer ratio I
C
/I
F
I
F
= 5 mA, V
CE
= 5 V
Rank GB
50 — 400
%
100 — 400
Saturated CTR I
C
/I
F(sat)
I
F
= 1 mA, V
CE
= 0.4 V
Rank GB
— 60 —
%
30 — —
Collector-emitter saturation voltage V
CE(sat)
I
C
= 2.4 mA, I
F
= 8 mA — — 0.3
V
I
C
= 0.2 mA, I
F
= 1 mA
Rank GB
— 0.2 —
— — 0.3
Off-state collector current I
C(off)
V
F
= 0.7 V, V
CE
= 48 V — 1 10 μA
Isolation Characteristics
(Ta = 25°C)
Characteristic Symbol Test Condition Min Typ. Max Unit
Capacitance (input to output) C
S
V
S
= 0 V, f = 1 MHz — 0.8 — pF
Isolation resistance R
S
V
S
= 500 V, R.H. ≤ 60% 1×10
10
— Ω
Isolation voltage BV
S
AC, 60 s 3750 — —
Vrms
AC, 1 s, in oil — 10000 —
DC, 60 s, in oil — 10000 — Vdc