17
IDT79R3041 INTEGRATED RISController FOR LOW COST SYSTEMS COMMERCIAL TEMPERATURE RANGE
ADVANCED
ADVANCED
DC ELECTRICAL CHARACTERISTICS RV3041 — (TC = 0°C to +85°C, VCC = +3.3V ±5%)
16.67MHz 20MHz 25MHz 33MHz
Symbol Parameter Test Conditions Min. Max. Min. Max. Min. Max. Min. Max. Unit
V
OH Output HIGH Voltage VCC = Min., IOH = –4mA 2.4 — 2.4 — 2.4 — 2.4 — V
VOL Output LOW Voltage VCC = Min., IOL = 4mA — 0.4 — 0.4 — 0.4 — 0.4 V
V
IH Input HIGH Voltage
(3)
— 2.0 — 2.0 — 2.0 — 2.0 — V
V
IL Input LOW Voltage
(1)
— — 0.8 — 0.8 — 0.8 — 0.8 V
VIHS Input HIGH Voltage
(2,3)
— 2.5 — 2.5 — 2.5 — 2.5 — V
V
ILS Input LOW Voltage
(1,2)
— — 0.4 — 0.4 — 0.4 — 0.4 V
C
IN Input Capacitance
(4)
— — 10 — 10 — 10 — 10 pF
COUT Output Capacitance
(4)
— — 10 — 10 — 10 — 10 pF
I
CC Operating Current VCC = 3.3V, TC = 25°C — 130 — 150 — 180 — 225 mA
I
IH Input HIGH Leakage VIH = VCC — 100 — 100 — 100 — 100 mA
IIL Input LOW Leakage VIL = GND –100 — –100 — –100 — –100 — mA
I
OZ Output Tri-state Leakage VOH = 2.4V, VOL = 0.5V –100 100 –100 100 –100 100 –100 100 mA
NOTES: 2905 tbl 10
1. VIL Min. = –3.0V for pulse width less than 15ns. VIL should not fall below –0.5 volts for larger periods.
2. VIHS and VILS apply to CIkIn and .
3. VIH should not be held above VCC + 0.5 volts.
4. Guaranteed by design.
AC ELECTRICAL CHARACTERISTICS RV3041
(1, 2, 3)
— (TC = 0°C to +85°C, VCC = +3.3V ±5%)
16.67MHz 20MHz 25MHz 33MHz
Symbol Signals Description Min. Max. Min. Max. Min. Max. Min. Max. Unit
t1 , , , Set-up to rising 11 — 8 — 5.5 — 5.5 — ns
t1a A/D Set-up to falling 12 — 9 — 7 — 7 — ns
t2 , , , Hold from rising 4 — 3 — 2.5 — 2.5 — ns
t2a A/D Hold from falling 2 — 2 — 1 — 1 — ns
t3 A/D, Addr, Diag, ALE, Tri-state from rising — 13 — 10 — 10 — 10 ns
, , (after driven condition)
t4 A/D, Addr, Diag, ALE, Driven from falling — 13 — 10 — 10 — 10 ns
, , (after tri-state condition)
t5 Asserted from rising — 10 — 8 — 7 — 7 ns
t6 Negated from falling — 10 — 8 — 7 — 7 ns
t7 , , , TC Valid from rising — 8 — 6 — 5 — 5 ns
t7a A/D Valid from rising — 12 — 9 — 8 — 8 ns
t7b Last Valid from rising — 12 — 9 — 8 — 8 ns
t8 ALE Asserted from rising — 5 — 4 — 4 — 4 ns
t9 ALE Negated from falling — 5 — 4 — 4 — 4 ns
t10 A/D Hold from ALE negated 2 — 2 — 2 — 1.5 ns
t11 Asserted from — 19 — 15 — 15 — 15 ns
t12 Asserted from A/D tri-state
(4)
0—0—0—0—ns
t14 A/D Driven from rising
(4)
0—0—0—0—ns
t15 , , , Negated from falling — 9 — 7 — 6 — 6 ns
, Last, TC
t16 Addr(3:0), BE 16(1:0) Valid from —11— 8—7— 7ns
t17 Diag Valid from — 15 — 12 — 11 — 11 ns
2905 tbl 11