I
NTEGRATED
C
IRCUITS
D
IVISION
CPC7695
4 www.ixysic.com R01
1.3 Absolute Maximum Ratings
Absolute maximum electrical ratings are at 25°C
Absolute maximum ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
1.4 ESD Rating
1.5 General Conditions
Unless otherwise specified, minimum and maximum
values are production testing requirements.
Typical values are characteristic of the device at 25°C,
and are the result of engineering evaluations. They are
provided for informational purposes only, and are not
part of the manufacturing testing requirements.
Specifications cover the operating temperature range
T
A
= -40°C to +85°C. Also, unless otherwise specified
all testing is performed with V
DD
= +5V
DC
, logic low
input voltage is 0V
DC
and logic high input voltage is
+5V
DC
.
Parameter Minimum Maximum Unit
+5V power supply (V
DD
)
-0.3 7 V
Battery Supply - -85 V
D
GND
to F
GND
separation
-5 +5 V
Logic input voltage -0.3
V
DD
+0.3
V
Logic input to switch output
isolation
-320V
Switch open-contact
isolation (SW1, SW2, SW3,
SW5, SW6, SW7, SW8,
SW9, SW10)
-320V
Switch open-contact
isolation (SW4)
-465V
Operating relative humidity 5 95 %
Operating temperature -40 +110 °C
Storage temperature -40 +150 °C
ESD Rating (Human Body Model)
1000V
I
NTEGRATED
C
IRCUITS
D
IVISION
CPC7695
R01 www.ixysic.com 5
1.6 Switch Specifications
1.6.1 Break Switches: SW1 and SW2
Parameter Test Conditions Symbol Minimum Typical Maximum Unit
Off-State
Leakage Current
V
SW1
(differential) = T
LINE
to T
BAT
V
SW2
(differential) = R
LINE
to R
BAT
All-Off state.
+25°C,
V
SW
(differential) = -320V to GND
V
SW
(differential) = +260V to -60V
I
SW
-
0.1
1 A
+85°C,
V
SW
(differential) = -330V to GND
V
SW
(differential) = +270V to -60V
0.3
-40°C,
V
SW
(differential) = -310V to GND
V
SW
(differential) = +250V to -60V
0.1
On-Resistance
I
SW
(on) = ±10mA, ±40mA,
R
BAT
and T
BAT
= -2V
+25°C
R
ON
-
14.5 -
+85°C 20.5 28
-40°C 10.5 -
On-Resistance
Matching
Per SW1 & SW2 On-Resistance test
conditions.
R
ON
- 0.15 0.55
DC current limit
V
SW
(on) = ±10V
+25°C
I
SW
- 225
-
mA+85°C 80 150
-40°C - 400 425
Dynamic current limit
(t 0.5 s)
Break switches on, all other switches
off. Apply ±1kV 10x1000s pulse with
appropriate protection in place.
I
SW
-2.5- A
Logic input to switch
output isolation
Logic inputs = GND
+25°C, V
SW
(T
LINE
, R
LINE
) = ±320V
I
SW
-0.1
1 A
+85°C, V
SW
(T
LINE
, R
LINE
) = ±330V
-0.3
-40°C, V
SW
(T
LINE
, R
LINE
) = ±310V
-0.1
Transient Immunity
100V
PP
Square Wave, 100Hz
(Not production tested - limits are
guaranteed by design and quality
control sampling audits.)
dV/dt 1500 2100 - V/s
I
NTEGRATED
C
IRCUITS
D
IVISION
CPC7695
6 www.ixysic.com R01
1.6.2 Ringing Return Switch: SW3
Parameter Test Conditions Symbol Minimum Typical Maximum Unit
Off-State
Leakage Current
V
SW3
(differential) = T
LINE
to T
RINGING
All-Off state.
+25°C,
V
SW
(differential) = -320V to GND
V
SW
(differential) = +260V to -60V
I
SW
-
0.1
1 A
+85°C,
V
SW
(differential) = -330V to GND
V
SW
(differential) = +270V to -60V
0.3
-40°C,
V
SW
(differential) = -310V to GND
V
SW
(differential) = +250V to -60V
0.1
On-Resistance
I
SW
(on) = ±0mA, ±10mA
+25°C
R
ON
-
60 -
+85°C 85 110
-40°C 45 -
DC current limit
V
SW
(on) = ± 10V
+25°C
I
SW
- 120
-mA+85°C 70 85
-40°C - 210
Dynamic current limit
(t 0.5 s)
Ringing switches on, all other switches
off. Apply ±1kV 10x1000s pulse with
appropriate protection in place.
I
SW
-2.5- A
Logic input to switch
output isolation
Logic inputs = GND
+25°C, V
SW
(T
RINGING
, T
LINE
)= ±320V
I
SW
-
0.1
1 A
+85°C, V
SW
(T
RINGING
, T
LINE
)= ±330V
0.3
-40°C, V
SW
(T
RINGING
, T
LINE
) = ±310V
0.1
Transient Immunity
100V
PP
Square Wave, 100Hz
(Not production tested - limits are
guaranteed by design and quality
control sampling audits.)
dV/dt 1500 2100 - V/s

CPC7695ZC

Mfr. #:
Manufacturer:
IXYS Integrated Circuits
Description:
Switch ICs - Various LCASw/Protection SCR 20-Pin SOIC, MTS
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: