SNDHS-2
SNDHS50A
DC-DC Converters Bus Converter
.
Power Module Value-added Type
SNDH S 50 A 05 -O
Ordering information
1 Series name
2 Single output
3 Output wattage
4 A : DC60-160V
5 Output voltage
6 Optional
C : with Coating
R : with Remote ON/OFF
Please refer to Instruction
manual 7.
1 2 3 4 5 6
MODEL SNDHS50A05 SNDHS50A12 SNDHS50A15 SNDHS50A24
MAX OUTPUT WATTAGE[W] 50.0 50.4 51.0 50.4
DC OUTPUT 5V 10A 12V 4.2A 15V 3.4A 24V 2.1A
SPECIFICATIONS
MODEL SNDHS50A05 SNDHS50A12 SNDHS50A15 SNDHS50A24
INPUT
VOLTAGE[V] DC60 - 160
CURRENT[A]
*1
0.55typ 0.55typ 0.55typ 0.55typ
EFFICIENCY[%]
*1
83.0typ 85.0typ 85.0typ 85.0typ
OUTPUT
VOLTAGE[V] 5 121524
CURRENT[A] 10 4.2 3.4 2.1
LINE REGULATION[mV] 10max 24max 30max 48max
LOAD REGULATION[mV] 150max 100max 100max 100max
RIPPLE[mVp-p]
0 to +95C
*2
80max 120max 120max 120max
-20 to 0C
*2
120max 150max 150max 150max
0 to 15% Load
*2
160max 240max 240max 240max
RIPPLE NOISE[mVp-p]
0 to +95C
*2
160max 200max 200max 200max
-20 to 0C
*2
250max 280max 280max 280max
0 to 15% Load
*2
300max 300max 300max 300max
TEMPERATURE REGULATION[mV]
0 to +50C
50max 120max 150max 240max
-20 to +95C
100max 240max 300max 480max
DRIFT[mV]
*
3
20max 40max 60max 90max
START-UP TIME[ms]
200max (DCIN 110V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
*
4
4.50 - 5.50 10.80 - 13.20 13.50 - 16.50 21.60 - 26.40
OUTPUT VOLTAGE SETTING[V]
5.00 - 5.15 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION[V]
6.30 - 7.60 13.90 - 17.55 17.25 - 21.75 27.60 - 34.80
REMOTE SENSING None
REMOTE ON/OFF (RC)
Optional (Required external power source)
ISOLATION
INPUT-OUTPUT, RC
*
5
AC3,000V 1minute, Cutoff current = 15mA, DC500V 50MW min (20±15C)
INPUT-FG
AC2,000V 1minute, Cutoff current = 15mA, DC500V 50MW min (20±15C)
OUTPUT, RC-FG
*
5
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (20±15C)
OUTPUT-RC
*
5
AC100V 1minute, Cutoff current = 25mA, DC100V 10MW min (20±15C)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
*
6
-20 to +95C (Aluminum base plate of the power module), 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000 feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +95C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max
VIBRATION 10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT 196.1m/s
2
(20G), 11ms, once each along X, Y and Z axis
SAFETY
AGENCY APPROVALS UL60950-1, C-UL, EN60950-1
CONDUCTED NOISE (at only DC input)
Complies with FCC-A, VCCI-A, CISPR22-A, EN55011-A, EN55022-A
OTHERS
CASE SIZE/WEIGHT
61.5X44.5X150mm [2.42X1.75X5.91 inches] (WXHXD) / 270g max
COOLING METHOD Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
*1 At rated input(DC110V) and rated load.
*2 Ripple and ripple noise is measured by using measuring board with capacitor of 22mF at 150mm [5.91 inches] from output terminal.
Refer to the instruction manual 3.2.
*3 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
*4 Refer to the instruction manual 4.6.
*5 Applicable when remote control (optional) is added.
*6 Refer to the instruction manual 6.2.
R
SNDHS
me_sndhs.indd 2me sndhs indd 2 2015/06/19 11:22:462015/06/19 11:22:46
SNDHS-3
SNDHS50A
External view
max
44.5
Voltage adjust
Connector for remote ON/OFF
(optional)
Name plate
Power module
Base plate
Mounting hole
Terminal cover
Terminal cover
Tolerance : ±1 [±0.04]
Weight
:
270g max
Dimensions in mm, [ ]=inches
PCB material/thickness
:
FR-4 / 1.6mm [0.06]
Base plate material/thickness : Alminum / 3.0mm[0.12]
[2.42]
[0.20]
[0.34]
[0.34]
[0.82]
[0.66]
[1.01]
[5.91]
[5.23][0.34]
[1.51]
[0.2]
[1.75 max]
[0.39]
[0.39]
[0.39]
[2.02
±
0.02]
[4-f0.177]
[5.51
±
0.02]
Mounting torque
:
1.6N
-
m (16.9kgf
-
cm) max
Please connect safety ground to the base plate
in f4.5 [f0.177] hole.
Component positions and sizes are for your reference
if they have no dimensions.
2
1
CN2
(DHS50A)
TB2
+Vout
-Vout
4-f4.5
M4
-Vin
+Vin
PointA
PointB
±
0.5
±
0.5
FG
M4
TB1
38.25
16.75
150
61.5
8.6
8.6
25.65
10
5.08
51.34
5.08
139.84
8.7
132.81
20.75
10
10
SNDHS
me_sndhs.indd 3me sndhs indd 3 2015/06/19 11:22:502015/06/19 11:22:50
SNDHS-4
SNDHS100A
DC-DC Converters Bus Converter
.
Power Module Value-added Type
SNDH S 100 A 05 -O
Ordering information
1 2 3 4 5 6
1 Series name
2 Single output
3 Output wattage
4 A : DC60-160V
5 Output voltage
6 Optional
C : with Coating
R : with Remote ON/OFF
Please refer to Instruction
manual 7.
MODEL SNDHS100A05 SNDHS100A12 SNDHS100A15 SNDHS100A24
MAX OUTPUT WATTAGE[W] 100.0 100.8 100.5 100.8
DC OUTPUT 5V 20A 12V 8.4A 15V 6.7A 24V 4.2A
SPECIFICATIONS
MODEL SNDHS100A05 SNDHS100A12 SNDHS100A15 SNDHS100A24
INPUT
VOLTAGE[V] DC60 - 160
CURRENT[A]
*1
1.1typ 1.1typ 1.1typ 1.1typ
EFFICIENCY[%]
*1
84.0typ 87.0typ 87.0typ 87.0typ
OUTPUT
VOLTAGE[V] 5 121524
CURRENT[A] 20 8.4 6.7 4.2
LINE REGULATION[mV] 10max 24max 30max 48max
LOAD REGULATION[mV] 150max 100max 100max 100max
RIPPLE[mVp-p]
0 to +95C
*2
80max 120max 120max 120max
-20 to 0C
*2
120max 150max 150max 150max
0 to 15% Load
*2
160max 240max 240max 240max
RIPPLE NOISE[mVp-p]
0 to +95C
*2
160max 200max 200max 200max
-20 to 0C
*2
250max 280max 280max 280max
0 to 15% Load
*2
300max 300max 300max 300max
TEMPERATURE REGULATION[mV]
0 to +50C
50max 120max 150max 240max
-20 to +95C
100max 240max 300max 480max
DRIFT[mV]
*
3
20max 40max 60max 90max
START-UP TIME[ms]
200max (DCIN 110V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
*
4
4.50 - 5.50 10.80 - 13.20 13.50 - 16.50 21.60 - 26.40
OUTPUT VOLTAGE SETTING[V]
5.00 - 5.15 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION[V]
6.30 - 7.60 13.90 - 17.55 17.25 - 21.75 27.60 - 34.80
REMOTE SENSING None
REMOTE ON/OFF (RC)
Optional (Required external power source)
ISOLATION
INPUT-OUTPUT, RC
*
5
AC3,000V 1minute, Cutoff current = 15mA, DC500V 50MW min (20±15C)
INPUT-FG
AC2,000V 1minute, Cutoff current = 15mA, DC500V 50MW min (20±15C)
OUTPUT, RC-FG
*
5
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (20±15C)
OUTPUT-RC
*
5
AC100V 1minute, Cutoff current = 25mA, DC100V 10MW min (20±15C)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
*
6
-20 to +95C (Aluminum base plate of the power module), 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000 feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +95C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max
VIBRATION 10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT 196.1m/s
2
(20G), 11ms, once each along X, Y and Z axis
SAFETY
AGENCY APPROVALS UL60950-1, C-UL, EN60950-1
CONDUCTED NOISE (at only DC input)
Complies with FCC-A, VCCI-A, CISPR22-A, EN55011-A, EN55022-A
OTHERS
CASE SIZE/WEIGHT
61.5X44.5X150mm [2.42X1.75X5.91 inches] (WXHXD) / 270g max
COOLING METHOD Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
*1 At rated input(DC110V) and rated load.
*2 Ripple and ripple noise is measured by using measuring board with capacitor of 22mF at 150mm [5.91 inches] from output terminal.
Refer to the instruction manual 3.2.
*3 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
*4 Refer to the instruction manual 4.6.
*5 Applicable when remote control (optional) is added.
*6 Refer to the instruction manual 6.2.
R
SNDHS
me_sndhs.indd 4me sndhs indd 4 2015/06/19 11:22:502015/06/19 11:22:50

SNDHS50B03

Mfr. #:
Manufacturer:
Cosel
Description:
Isolated DC/DC Converters 50W 3.3V 10A VALUE ADDED
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union