MODEL SNDHS50B03 SNDHS50B05 SNDHS50B12 SNDHS50B15 SNDHS50B24 SNDHS50B28
MAX OUTPUT WATTAGE[W] 33.0 50.0 50.4 51.0 50.4 50.4
DC OUTPUT 3.3V 10A 5V 10A 12V 4.2A 15V 3.4A 24V 2.1A 28V 1.8A
SPECIFICATIONS
MODEL SNDHS50B03 SNDHS50B05 SNDHS50B12 SNDHS50B15 SNDHS50B24 SNDHS50B28
INPUT
VOLTAGE[V]
DC200 - 400 (Prepare another power supply to the RC1 terminal
*
5
)
CURRENT[A]
*1
0.15typ 0.22typ 0.22typ 0.22typ 0.22typ 0.22typ
EFFICIENCY[%]
*1
76.0typ 79.0typ 82.0typ 82.0typ 82.0typ 82.0typ
OUTPUT
VOLTAGE[V] 3.35 12152428
CURRENT[A] 10 10 4.2 3.4 2.1 1.8
LINE REGULATION[mV] 10max 10max 24max 30max 48max 56max
LOAD REGULATION[mV] 150max 150max 100max 100max 100max 100max
RIPPLE[mVp-p]
0 to +95C
*2
80max 80max 120max 120max 120max 120max
-20 to 0C
*2
120max 120max 150max 150max 150max 150max
0 to 15% Load
*2
160max 160max 240max 240max 240max 240max
RIPPLE NOISE[mVp-p]
0 to +95C
*2
160max 160max 200max 200max 200max 200max
-20 to 0C
*2
250max 250max 280max 280max 280max 280max
0 to 15% Load
*2
300max 300max 300max 300max 300max 300max
TEMPERATURE REGULATION[mV]
0 to +50C
35max 50max 120max 150max 240max 280max
-20 to +95C
66max 100max 240max 300max 480max 560max
DRIFT[mV]
*
3
16max 20max 40max 60max 90max 90max
START-UP TIME[ms]
200max (DCIN 280V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
*
4
2.97 - 3.63 4.50 - 5.50 10.80 - 13.20 13.50 - 16.50 21.60 - 26.40 25.20 - 30.80
OUTPUT VOLTAGE SETTING[V]
3.30 - 3.40 5.00 - 5.15 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 28.00 - 29.12
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION[V]
4.20 - 5.70 6.30 - 7.60 13.90 - 17.55 17.25 - 21.75 27.60 - 34.80 32.20 - 40.60
REMOTE SENSING None
REMOTE ON/OFF (RC1)
*
6
Provided (Logic H : ON, L :OFF) Required external power source
ISOLATION
INPUT-OUTPUT, RC2
*
8
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)
INPUT-FG
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)
OUTPUT, RC2-FG
*
8
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (20±15C)
OUTPUT-RC2
*
8
AC100V 1minute, Cutoff current = 25mA, DC100V 10MW min (20±15C)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
*
7
-20 to +95C (Aluminum base plate of the power module), 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000 feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +95C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max
VIBRATION 10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT 196.1m/s
2
(20G), 11ms, once each along X, Y and Z axis
SAFETY AGENCY APPROVALS UL60950-1, C-UL, EN60950-1
OTHERS
CASE SIZE/WEIGHT
61.5X44.5X127mm [2.42X1.75X5.0 inches] (WXHXD) / 220g max
COOLING METHOD Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
R
*1 At rated input(DC280V) and rated load.
*2 Ripple and ripple noise is measured by using measuring board with capacitor of 22mF at
150mm [5.91 inches] from output terminal.
Refer to the instruction manual 3.2.
*3 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C,
with the input voltage held constant at the rated input/output.
*4 Refer to the instruction manual 4.6.
*5 Refer to the instruction manual 2, 4.4
*6 Refer to the instruction manual 4.4
*7 Refer to the instruction manual 6.2
*8 "RC2" is applicable to an option not to need external power source.
SNDHS
me_sndhs.indd 8me sndhs indd 8 2015/06/19 11:22:572015/06/19 11:22:57
SNDHS-9
SNDHS50B
External view
4-f4.5
CN2
CN1
TB1
+Vout
-Vout
M4
1
2
4
max
4
2
1
RC1
-Vin
+Vin
PointA
PointB
CN3
1
2
8.7
127
61.5
44.5
8.6
26.2
10
5.08
51.34
5.08
116.84
(DHS50B)
±
0.5
Voltage adjust
Connector for remote ON/OFF (optional)
Name plate
Power module
Base plate
Mounting hole
Terminal cover
Tolerance : ±1 [±0.04]
Weight
:
220g max
Dimensions in mm, [ ]=inches
PCB material/thickness
:
FR-4 / 1.6mm [0.06]
Base plate material/thickness : Alminum / 3.0mm[0.12]
[2.42]
[0.20]
[1.03]
[0.34]
[0.74]
[0.34]
[1.69]
[5.00]
[1.75 max]
[0.20]
[0.39]
[2.02
±
0.02]
[4-f0.177]
[4.60
±
0.02]
Screw tightening torque
:
1.6N
-
m (16.9kgf
-
cm) max
Please connect safety ground to the base plate
in f4.5 [f0.177] hole.
Component positions and sizes are for your reference
if they have no dimensions.
18.7
43
CN4
1
2
±
0.5
SNDHS
me_sndhs.indd 9me sndhs indd 9 2015/06/19 11:23:012015/06/19 11:23:01
SNDHS-10
SNDHS100B
DC-DC Converters Bus Converter
.
Power Module Value-added Type
SNDH S 100 B 05 -O
Ordering information
1 2 3 4 5 6
1 Series name
2 Single output
3 Output wattage
4 B : DC200-400V
5 Output voltage
6 Optional
C : with Coating
R :
with a function not to need
external power source
MODEL SNDHS100B03 SNDHS100B05 SNDHS100B12 SNDHS100B15 SNDHS100B24 SNDHS100B28
MAX OUTPUT WATTAGE[W] 66.0 100.0 100.8 100.5 100.8 100.8
DC OUTPUT 3.3V 20A 5V 20A 12V 8.4A 15V 6.7A 24V 4.2A 28V 3.6A
SPECIFICATIONS
MODEL SNDHS100B03 SNDHS100B05 SNDHS100B12 SNDHS100B15 SNDHS100B24 SNDHS100B28
INPUT
VOLTAGE[V]
DC200 - 400 (Prepare another power supply to the RC1 terminal
*
5
)
CURRENT[A]
*1
0.30typ 0.44typ 0.42typ 0.42typ 0.42typ 0.42typ
EFFICIENCY[%]
*1
78.0typ 81.0typ 84.0typ 85.0typ 85.0typ 85.0typ
OUTPUT
VOLTAGE[V] 3.35 12152428
CURRENT[A] 20 20 8.4 6.7 4.2 3.6
LINE REGULATION[mV] 10max 10max 24max 30max 48max 56max
LOAD REGULATION[mV] 150max 150max 100max 100max 100max 100max
RIPPLE[mVp-p]
0 to +95C
*2
80max 80max 120max 120max 120max 120max
-20 to 0C
*2
120max 120max 150max 150max 150max 150max
0 to 15% Load
*2
160max 160max 240max 240max 240max 240max
RIPPLE NOISE[mVp-p]
0 to +95C
*2
160max 160max 200max 200max 200max 200max
-20 to 0C
*2
250max 250max 280max 280max 280max 280max
0 to 15% Load
*2
300max 300max 300max 300max 300max 300max
TEMPERATURE REGULATION[mV]
0 to +50C
35max 50max 120max 150max 240max 280max
-20 to +95C
66max 100max 240max 300max 480max 560max
DRIFT[mV]
*
3
16max 20max 40max 60max 90max 90max
START-UP TIME[ms]
200max (DCIN 280V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
*
4
2.97 - 3.63 4.50 - 5.50 10.80 - 13.20 13.50 - 16.50 21.60 - 26.40 25.20 - 30.80
OUTPUT VOLTAGE SETTING[V]
3.30 - 3.40 5.00 - 5.15 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 28.00 - 29.12
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION[V]
4.20 - 5.70 6.30 - 7.60 13.90 - 17.55 17.25 - 21.75 27.60 - 34.80 32.20 - 40.60
REMOTE SENSING None
REMOTE ON/OFF (RC1)
*
6
Provided (Logic H : ON, L :OFF) Required external power source
ISOLATION
INPUT-OUTPUT, RC2
*
8
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)
INPUT-FG
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)
OUTPUT, RC2-FG
*
8
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (20±15C)
OUTPUT-RC2
*
8
AC100V 1minute, Cutoff current = 25mA, DC100V 10MW min (20±15C)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
*
7
-20 to +95C (Aluminum base plate of the power module), 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000 feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +95C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max
VIBRATION 10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT 196.1m/s
2
(20G), 11ms, once each along X, Y and Z axis
SAFETY AGENCY APPROVALS UL60950-1, C-UL, EN60950-1
OTHERS
CASE SIZE/WEIGHT
61.5X44.5X127mm [2.42X1.75X5.0 inches] (WXHXD) / 220g max
COOLING METHOD Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
R
*1 At rated input(DC280V) and rated load.
*2 Ripple and ripple noise is measured by using measuring board with capacitor of 22mF at
150mm [5.91 inches] from output terminal.
Refer to the instruction manual 3.2.
*3 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C,
with the input voltage held constant at the rated input/output.
*4 Refer to the instruction manual 4.6.
*5 Refer to the instruction manual 2, 4.4
*6 Refer to the instruction manual 4.4
*7 Refer to the instruction manual 6.2
*8 "RC2" is applicable to an option not to need external power source.
SNDHS
me_sndhs.indd 10me sndhs indd 10 2015/06/19 11:23:022015/06/19 11:23:02

SNDHS50B03

Mfr. #:
Manufacturer:
Cosel
Description:
Isolated DC/DC Converters 50W 3.3V 10A VALUE ADDED
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union