.......................DOC #: SP-AP-0021 (Rev AA) Page 22 of 28
T
PERIODSSAbs
400 MHz CPU Clock Absolute period,
SSC
Measured at 0V differential at 1 clock
2.41477 2.59780
ns
T
CCJ
CPU Cycle to Cycle Jitter Measured at 0V differential –85ps
T
CCJ2
CPU2_ITP Cycle to Cycle Jitter Measured at 0V differential –125ps
L
ACC
Long-term Accuracy Measured at 0V differential –100ppm
T
SKEW
CPU0 to CPU1 Clock Skew Measured at 0V differential –100ps
T
SKEW2
CPU2_ITP to CPU0 Clock Skew Measured at 0V differential –150ps
T
R
/ T
F
CPU Rising/Falling Slew rate Measured differentially from ±150 mV 2.5 8 V/ns
T
RFM
Rise/Fall Matching Measured single-endedly from ±75 mV –20%
V
HIGH
Voltage High 1.15 V
V
LOW
Voltage Low –0.3 – V
V
OX
Crossing Point Voltage at 0.7V Swing 300 550 mV
SRC at 0.7V
T
DC
SRC Duty Cycle Measured at 0V differential 45 55 %
T
PERIOD
100 MHz SRC Period Measured at 0V differential at 0.1s
9.99900 10.0010
ns
T
PERIODSS
100 MHz SRC Period, SSC Measured at 0V differential at 0.1s
10.02406 10.02607
ns
T
PERIODAbs
100 MHz SRC Absolute Period Measured at 0V differential at 1 clock
9.87400 10.1260
ns
T
PERIODSSAbs
100 MHz SRC Absolute Period, SSC Measured at 0V differential at 1 clock
9.87406 10.1762
ns
T
SKEW(window)
Any SRC Clock Skew from the earliest
bank to the latest bank
Measured at 0V differential –3.0ns
T
CCJ
SRC Cycle to Cycle Jitter Measured at 0V differential –125ps
L
ACC
SRC Long Term Accuracy Measured at 0V differential –100ppm
T
R
/ T
F
SRC Rising/Falling Slew Rate Measured differentially from ±150 mV 2.5 8 V/ns
T
RFM
Rise/Fall Matching Measured single-endedly from ±75 mV –20%
V
HIGH
Voltage High 1.15 V
V
LOW
Voltage Low –0.3 – V
V
OX
Crossing Point Voltage at 0.7V Swing 300 550 mV
DOT96 at 0.7V
T
DC
DOT96 Duty Cycle Measured at 0V differential 45 55 %
T
PERIOD
DOT96 Period Measured at 0V differential at 0.1s
10.4156 10.4177
ns
T
PERIODAbs
DOT96 Absolute Period Measured at 0V differential at 0.1s
10.1656 10.6677
ns
T
CCJ
DOT96 Cycle to Cycle Jitter Measured at 0V differential at 1 clock –250ps
L
ACC
DOT96 Long Term Accuracy Measured at 0V differential at 1 clock –100ppm
T
R
/ T
F
DOT96 Rising/Falling Slew Rate Measured differentially from ±150 mV 2.5 8 V/ns
T
RFM
Rise/Fall Matching Measured single-endedly from ±75 mV –20%
V
HIGH
Voltage High 1.15 V
V
LOW
Voltage Low –0.3 – V
V
OX
Crossing Point Voltage at 0.7V Swing 300 550 mV
LCD_100_SSC at 0.7V
T
DC
LCD_100 Duty Cycle Measured at 0V differential 45 55 %
T
PERIOD
100 MHz LCD_100 Period Measured at 0V differential at 0.1s 9.99900 10.0010 ns
T
PERIODSS
100 MHz LCD_100 Period, SSC -0.5% Measured at 0V differential at 0.1s 10.02406 10.02607 ns
T
PERIODAbs
100 MHz LCD_100 Absolute Period Measured at 0V differential at 1 clock 9.74900 10.25100 ns
T
PERIODSSAbs
100 MHz LCD_100 Absolute Period,
SSC
Measured at 0V differential at 1 clock 9.74906 10.3012 ns
AC Electrical Specifications (continued)
Parameter Description Condition Min. Max. Unit