ACPL-W483-000E

4
ACPL-P483 Stretched SO-6 Package, 7 mm clearance
ACPL-W483 Stretched SO-6 Package, 8 mm clearance
45°
NOM.
0.381 ±0.127
(0.015 ±0.005)
1.27 (0.050) BSG
4.580
+ 0.254
0
3.180 ±0.127
(0.125 ±0.005)
1.590 ±0.127
(0.063 ±0.005)
0.254 ±0.050
(0.010 ±0.002)
9.7 ±0.250
(0.382 ±0.010)
Floating Lead Protusions max. 0.25 (0.01)
Dimensions in Millimeters (Inches)
Lead Coplanarity = 0.1 mm (0.004 Inches)
0.180
+ 0.010
0.000
()
1 ±0.250
(0.040 ±0.010)
0.20 ±0.10
(0.008 ±0.004)
7.62 (0.300)
6.81 (0.268)
0.45 (0.018)
10.7
(0.421)
1.27 (0.05)
0.64 (0.025)
2.16
(0.085)
Land Pattern Recommendation
45°
2
1
34
5
6
0.381 ±0.127
(0.015 ±0.005)
0.20 ±0.10
(0.008 ±0.004)
Floating Lead Protusions max. 0.25 (0.01)
Dimensions in Millimeters (Inches)
Lead Coplanarity = 0.1 mm (0.004 Inches)
4.580
+ 0.254
0
0.180
+ 0.010
0.000
()
6.807
+ 0.127
0
0.268
+ 0.005
0.000
()
1.27 (0.050) BSG
35°
NOM.
0.750 ±0.250
(0.0295 ±0.010)
11.500 ±0.25
(0.453 ±0.010)
0.254 ±0.050
(0.010 ±0.002)
1.590 ±0.127
(0.063 ±0.005)
3.180 ±0.127
(0.125 ±0.005)
0.45 (0.018)
7.62 (0.300)
12.65
(0.5)
1.27 (0.05)
0.64 (0.025)
1.905
(0.075)
Land Pattern Recommendation
5
Recommended Pb-Free IR Pro le
Recommended re ow condition as per JEDEC Standard, J-STD-020 (latest revision). Non-Halide Flux should be used.
Regulatory Information
The ACPL-M483/P483/W483 is approved by the following organizations:
IEC/EN/DIN EN 60747-5-5 (Option 060 only)
Approved with Maximum Working Insulation Voltage V
IORM
= 567 V
peak
for ACPL-M483, V
IORM
= 891 V
peak
for ACPL-P483,
and V
IORM
= 1140 V
peak
for ACPL-W483
UL
Approval under UL 1577, component recognition program up to V
ISO
= 3750 V
RMS
File E55361 for ACPL-M483 and
ACPL-P483;
Approval under UL 1577, component recognition program up to V
ISO
= 5000 V
RMS
File E55361 for ACPL-W483;
CSA
Approval under CSA Component Acceptance Notice #5, File CA 88324.
Table 1. IEC/EN/DIN EN 60747-5-5 Insulation Characteristics* (ACPL-M483/P483/W483 Option 060)
Description Symbol ACPL-M483 ACPL-P483 ACPL-W483 Unit
Installation classi cation per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤ 150 V
rms
for rated mains voltage ≤ 300 V
rms
for rated mains voltage ≤ 450 V
rms
for rated mains voltage ≤ 600 V
rms
for rated mains voltage ≤ 1000 V
rms
I – IV
I – IV
I – III
I – III
I – IV
I – IV
I – III
I – III
I – IV
I – IV
I – IV
I – IV
I – III
Climatic Classi cation 55/105/21 55/105/21 55/105/21
Pollution Degree (DIN VDE 0110/1.89) 2 2 2
Maximum Working Insulation Voltage V
IORM
567 891 1140 V
peak
Input to Output Test Voltage, Method b*
V
IORM
x 1.875 = V
PR
, 100% Production Test with t
m
= 1 sec,
Partial discharge < 5 pC
V
PR
1063 1670 2137 V
peak
Input to Output Test Voltage, Method a*
V
IORM
x 1.6 = V
PR
, Type and Sample Test, t
m
= 10 sec,
Partial discharge < 5 pC
V
PR
907 1426 1824 V
peak
Highest Allowable Overvoltage
(Transient Overvoltage t
ini
= 60 sec)
V
IOTM
6000 6000 8000 V
peak
Safety-limiting values – maximum values allowed in
the event of a failure.
Case Temperature
Input Current
Output Power
T
S
I
S, INPUT
P
S, OUTPUT
175
230
600
175
230
600
175
230
600
°C
mA
mW
Insulation Resistance at T
S
, V
IO
= 500 V R
S
>10
9
>10
9
>10
9
* Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section,
(IEC/EN/DIN EN 60747-5-2) for a detailed description of Method a and Method b partial discharge test pro les.
6
Table 2. Insulation and Safety Related Speci cations
Parameter Symbol ACPL-M483 ACPL-P483 ACPL-W483 Units Conditions
Minimum External Air Gap
(External Clearance)
L(101) 5.0 7.0 8.0 mm Measured from input terminals to
output terminals, shortest distance
through air.
Minimum External Tracking
(External Creepage)
L(102) 5.0 8.0 8.0 mm Measured from input terminals to out-
put terminals, shortest distance path
along body.
Minimum Internal Plastic Gap
(Internal Clearance)
0.08 0.08 0.08 mm Through insulation distance conductor
to conductor, usually the straight line
distance thickness between the
emitter and detector.
Tracking Resistance
(Comparative Tracking Index)
CTI >175 >175 >175 V DIN IEC 112/VDE 0303 Part 1
Isolation Group IIIa IIIa IIIa Material Group (DIN VDE 0110, 1/89,
Table 1)
Table 3. Absolute Maximum Ratings
Parameter Symbol Min. Max. Units Note
Storage Temperature T
S
-55 125 °C
Operating Temperature T
A
-40 105 °C
Average Input Current I
F(avg)
10 mA
Peak Transient Input Current
(<1 s pulse width, 300 pps)
(<200 s pulse width, < 1% duty cycle)
I
F(tran)
1.0
40
A
mA
Reverse Input Voltage V
R
5V
Average Output Current I
O
50 mA
Supply Voltage V
CC
035
Output Voltage V
O
-0.5 35
Total Package Power Dissipation (ACPL-M483) P
T
145 mW 1
Total Package Power Dissipation (Others) P
T
210 mW 1
Solder Re ow Temperature Pro le See Re ow Thermal Pro le.
Table 4. Recommended Operating Conditions
Parameter Symbol Min. Max. Units Note
Power Supply Voltage
(1)
V
CC
4.5 30 V 2
Forward Input Current (ON) I
F(ON)
47mA
Forward Input Voltage (OFF) V
F(OFF)
0.8 V
Operating Temperature T
A
–40 105 °C
Note:
1. Truth Table guaranteed: 4.5 V to 30 V

ACPL-W483-000E