74LVC2GU04 All information provided in this document is subject to legal disclaimers. © NXP Semiconductors N.V. 2017. All rights reserved.
Product data sheet Rev. 10 — 10 February 2017 3 of 19
NXP Semiconductors
74LVC2GU04
Dual unbuffered inverter
6.2 Pin description
7. Functional description
[1] H = HIGH voltage level; L = LOW voltage level.
8. Limiting values
[1] The minimum input and output voltage ratings may be exceeded if the input and output current ratings are observed.
[2] When V
CC
= 0 V (Power-down mode), the output voltage can be 5.5 V in normal operation.
[3] For SC-88 and SC-74 packages: above 87.5 C the value of P
tot
derates linearly with 4.0 mW/K.
For XSON6 packages: above 118 C the value of P
tot
derates linearly with 7.8 mW/K.
Table 3. Pin description
Symbol Pin Description
1A 1 data input
GND 2 ground (0 V)
2A 3 data input
2Y 4 data output
V
CC
5 supply voltage
1Y 6 data output
Table 4. Function table
[1]
Input Output
nA nY
LH
HL
Table 5. Limiting values
In accordance with the Absolute Maximum Rating System (IEC 60134). Voltages are referenced to GND (ground = 0 V).
Symbol Parameter Conditions Min Max Unit
V
CC
supply voltage 0.5 +6.5 V
I
IK
input clamping current V
I
< 0 V 50 - mA
V
I
input voltage
[1]
0.5 +6.5 V
I
OK
output clamping current V
O
< 0 V 50 - mA
V
O
output voltage Active mode
[1][2]
0.5 V
CC
+ 0.5 V
I
O
output current V
O
= 0 V to V
CC
- 50 mA
I
CC
supply current - 100 mA
I
GND
ground current 100 - mA
T
stg
storage temperature 65 +150 C
P
tot
total power dissipation T
amb
= 40 C to +125 C
[3]
-250mW
74LVC2GU04 All information provided in this document is subject to legal disclaimers. © NXP Semiconductors N.V. 2017. All rights reserved.
Product data sheet Rev. 10 — 10 February 2017 4 of 19
NXP Semiconductors
74LVC2GU04
Dual unbuffered inverter
9. Recommended operating conditions
10. Static characteristics
Table 6. Recommended operating conditions
Voltages are referenced to GND (ground = 0 V).
Symbol Parameter Conditions Min Typ Max Unit
V
CC
supply voltage 1.65 - 5.5 V
V
I
input voltage 0 - 5.5 V
V
O
output voltage Active mode 0 - V
CC
V
T
amb
ambient temperature 40 - +125 C
t/V input transition rise and fall rate V
CC
= 1.65 V to 2.7 V - - 20 ns/V
V
CC
= 2.7 V to 5.5 V - - 10 ns/V
Table 7. Static characteristics
At recommended operating conditions; voltages are referenced to GND (ground = 0 V).
Symbol Parameter Conditions Min Typ Max Unit
T
amb
= 40 C to +85 C
[1]
V
IH
HIGH-level input voltage V
CC
= 1.65 V to 5.5 V 0.75 V
CC
--V
V
IL
LOW-level input voltage V
CC
= 1.65 V to 5.5 V - - 0.25 V
CC
V
V
OH
HIGH-level output voltage V
I
= V
IH
or V
IL
I
O
= 100 A;
V
CC
= 1.65 V to 5.5 V
V
CC
 0.1 - - V
I
O
= 4 mA; V
CC
= 1.65 V 1.2 - - V
I
O
= 8 mA; V
CC
= 2.3 V 1.9 - - V
I
O
= 12 mA; V
CC
= 2.7 V 2.2 - - V
I
O
= 24 mA; V
CC
= 3.0 V 2.3 - - V
I
O
= 32 mA; V
CC
= 4.5 V 3.8 - - V
V
OL
LOW-level output voltage V
I
= V
IH
or V
IL
I
O
= 100 A;
V
CC
= 1.65 V to 5.5 V
--0.1V
I
O
= 4 mA; V
CC
=1.65 V - - 0.45 V
I
O
= 8 mA; V
CC
= 2.3 V - - 0.3 V
I
O
= 12 mA; V
CC
= 2.7 V - - 0.4 V
I
O
= 24 mA; V
CC
= 3.0 V - - 0.55 V
I
O
= 32 mA; V
CC
= 4.5 V - - 0.55 V
I
I
input leakage current V
I
= 5.5 V or GND;
V
CC
=0Vto5.5V
[2]
- 0.1 1 A
I
CC
supply current V
I
= 5.5 V or GND; I
O
= 0 A;
V
CC
= 1.65 V to 5.5 V
-0.14A
C
I
input capacitance V
CC
=3.3V; V
I
= GND to V
CC
-5-pF
74LVC2GU04 All information provided in this document is subject to legal disclaimers. © NXP Semiconductors N.V. 2017. All rights reserved.
Product data sheet Rev. 10 — 10 February 2017 5 of 19
NXP Semiconductors
74LVC2GU04
Dual unbuffered inverter
[1] All typical values are measured at T
amb
= 25 C.
[2] These typical values are measured at V
CC
=3.3V.
T
amb
= 40 C to +125 C
V
IH
HIGH-level input voltage V
CC
= 1.65 V to 5.5 V 0.8 V
CC
--V
V
IL
LOW-level input voltage V
CC
= 1.65 V to 5.5 V - - 0.2 V
CC
V
V
OH
HIGH-level output voltage V
I
= V
IH
or V
IL
I
O
= 100 A;
V
CC
= 1.65 V to 5.5 V
V
CC
 0.1 - - V
I
O
= 4 mA; V
CC
= 1.65 V 0.95 - - V
I
O
= 8 mA; V
CC
= 2.3 V 1.7 - - V
I
O
= 12 mA; V
CC
= 2.7 V 1.9 - - V
I
O
= 24 mA; V
CC
= 3.0 V 2.0 - - V
I
O
= 32 mA; V
CC
= 4.5 V 3.4 - - V
V
OL
LOW-level output voltage V
I
= V
IH
or V
IL
I
O
= 100 A;
V
CC
= 1.65 V to 5.5 V
--0.1V
I
O
= 4 mA; V
CC
= 1.65 V - - 0.7 V
I
O
= 8 mA; V
CC
= 2.3 V - - 0.45 V
I
O
= 12 mA; V
CC
= 2.7 V - - 0.6 V
I
O
= 24 mA; V
CC
= 3.0 V - - 0.8 V
I
O
= 32 mA; V
CC
= 4.5 V - - 0.8 V
I
I
input leakage current V
I
= 5.5 V or GND;
V
CC
=0Vto5.5V
--1 A
I
CC
supply current V
I
= 5.5 V or GND; I
O
= 0 A;
V
CC
= 1.65 V to 5.5 V
--4A
Table 7. Static characteristics
…continued
At recommended operating conditions; voltages are referenced to GND (ground = 0 V).
Symbol Parameter Conditions Min Typ Max Unit

74LVC2GU04GW,125

Mfr. #:
Manufacturer:
Nexperia
Description:
Inverters 3.3V DUAL INVERTER
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS