TLP117
2014-09-01
2
Absolute Maximum Ratings (Ta=25°C)
Characteristic Symbol Rating Unit
LED
Forward current I
F
25 mA
Forward current derating (Ta≥85°C) ∆IF/∆Ta -0. 7 m A / °C
Peak transient forward current (Note 1) I
FPT
1 A
Reverse voltage V
R
6 V
DETECTOR
Output current I
O
10 mA
Output voltage V
O
6 V
Supply voltage V
CC
6 V
Output power dissipation P
O
40 mW
Operating temperature range T
opr
-40 to 105 °C
Storage temperature range T
stg
-55 to 125 °C
Lead solder temperature(10s) T
sol
260 °C
Isolation voltage (AC,1 minute, R.H. ≤ 60%, Ta=25°C) (Note 2) BVs 3750 Vrms
Note: Using continuously under heavy loads (e.g. the application of high temperature/current/voltage and the
significant change in temperature, etc.) may cause this product to decrease in the reliability significantly even if
the operating conditions (i.e. operating temperature/current/voltage, etc.) are within the absolute maximum
ratings.
Please design the appropriate reliability upon reviewing the Toshiba Semiconductor Reliability Handbook
(“Handling Precautions”/“Derating Concept and Methods”) and individual reliability data (i.e. reliability test
report and estimated failure rate, etc).
Note 1: Pulse width PW≤1μs, 300 pps.
Note 2: This device is regarded as a two-terminal device: pins 1 and 3 are shorted together, and pins 4,5 and 6 are
shorted together.
Recommended Operating Conditions
Characteristic Symbol Min Typ. Max Unit
Input current , ON I
F
ON
10
—
16 mA
Input voltage , OFF V
F
OFF
0
—
1.0 V
Supply voltage(*) (Note 3)
V
CC
4.5 5.0 5.5 V
* This item denotes operating ranges, not meaning of recommended operating conditions.
Note: Recommended operating conditions are given as a design guideline to obtain expected performance of the
device. Additionally, each item is an independent guideline respectively. In developing designs using this
product, please confirm specified characteristics shown in this document.
Note 3: The detector of this product requires a power supply voltage (
V
CC
) of 4.5 V or higher for stable operation. If
V
CC
is lower than this value, I
CC
may increase or the output may be unstable.
Be sure to use the product after checking the supply current, and the operation of a power-on/-off.