USA/Canada:
Toll Free:
Europe:
(315) 432-8909
(800) 411-6596
+44 2392-232392
Available on Tape and
Reel for Pick and Place
Manufacturing.
Model XEC24P3-30G
Rev B
2400 2410 2420 2430 2440 2450 2460 2470 2480 2490 2500
-50
-40
-30
-20
-10
0
Frequency (MHz)
Return Loss (dB)
Return Loss for XEC24P3-30G (Feeding Port 1)
-55ºC
25ºC
95ºC
150ºC
2400 2410 2420 2430 2440 2450 2460 2470 2480 2490 2500
-50
-40
-30
-20
-10
0
Frequency (MHz)
Return Loss (dB)
Return Loss for XEC24P3-30G (Feeding Port 2)
-55ºC
25ºC
95ºC
150ºC
2400 2410 2420 2430 2440 2450 2460 2470 2480 2490 2500
-50
-40
-30
-20
-10
0
Frequency (MHz)
Return Loss (dB)
Return Loss for XEC24P3-30G (Feeding Port 3)
-55ºC
25ºC
95ºC
150ºC
2400 2410 2420 2430 2440 2450 2460 2470 2480 2490 2500
-50
-40
-30
-20
-10
0
Frequency (MHz)
Return Loss (dB)
Return Loss for XEC24P3-30G (Feeding Port 4)
-55ºC
25ºC
95ºC
150ºC
Available on Tape
and Reel for Pick and
Place Manufacturing.
USA/Canada:
Toll Free:
Europe
:
(315) 432-8909
(800) 411-6596
+44 2392-232392
Model XEC24P3-30G
Rev B
Typical Performance (-55°C, 25°C, 95°C & 150°C): 2400-2500 MHz
2400 2410 2420 2430 2440 2450 2460 2470 2480 2490 2500
-33
-32
-31
-30
-29
-28
-27
Frequency (MHz)
Coupling (dB)
Coupling for XEC24P3-30G (Feeding Port 1)
-55ºC
25ºC
95ºC
150ºC
2400 2410 2420 2430 2440 2450 2460 2470 2480 2490 2500
-0.2
-0.15
-0.1
-0.05
0
Frequency (MHz)
Insertion Loss (dB)
Insertion Loss for XEC24P3-30G (Feeding Port 1)
-55ºC
25ºC
95ºC
150ºC
2400 2410 2420 2430 2440 2450 2460 2470 2480 2490 2500
-50
-40
-30
-20
-10
0
Frequency (MHz)
Directivity (dB)
Directivity for XEC24P3-30G (Feeding Port 1)
-55ºC
25ºC
95ºC
150ºC
2400 2410 2420 2430 2440 2450 2460 2470 2480 2490 2500
-0.2
-0.15
-0.1
-0.05
0
Frequency (MHz)
Transmission Loss (dB)
Transmission Loss for XEC24P3-30G (Feeding Port 1)
-55ºC
25ºC
95ºC
150ºC
USA/Canada:
Toll Free:
Europe:
(315) 432-8909
(800) 411-6596
+44 2392-232392
Available on Tape and
Reel for Pick and Place
Manufacturing.
Model XEC24P3-30G
Rev B
Definition of Measured Specifications
Parameter Definition Mathematical Representation
VSWR
(Voltage Standing Wave Ratio)
The impedance match of
the coupler to a 50:
system. A VSWR of 1:1 is
optimal.
VSWR =
min
max
V
V
Vmax = voltage maxima of a standing wave
Vmin = voltage minima of a standing wave
Return Loss
The impedance match of
the coupler to a 50:
system. Return Loss is
an alternate means to
express VSWR.
Return Loss (dB)= 20log
1-VSW
R
1VSWR
Mean Coupling
At a given frequency (Z
n
),
coupling is the input
power divided by the
power at the coupled
port. Mean coupling is
the average value of the
coupling values in the
band. N is the number of
frequencies in the band.
Coupling (dB) =
¸
¸
¹
·
¨
¨
©
§
)(
)(
log10)(
ncpl
nin
n
P
P
C
Z
Z
Z
Mean Coupling (dB) =
N
C
N
n
n
¦
1
)(
Z
Insertion Loss
The input power divided
by the sum of the power
at the two output ports.
10log
directcpl
in
PP
P
Transmission Loss
The input power divided
by the power at the direct
port.
10log
direct
in
P
P
Directivity
The power at the
coupled port divided by
the power at the isolated
port.
10log
iso
cpl
P
P
Frequency Sensitivity
The decibel difference
between the maximum in
band coupling value and
the mean coupling, and
the decibel difference
between the minimum in
band coupling value and
the mean coupling.
Max Coupling (dB) – Mean Coupling (dB)
and
Min Coupling (dB) – Mean Coupling (dB)

XEC24P3-30GR

Mfr. #:
Manufacturer:
Anaren
Description:
RF DIR COUPLER 2.4GHZ-2.5GHZ SMD
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet