MC10H680FNR2

MC10H680, MC100H680
http://onsemi.com
4
Table 6. 100H DC CHARACTERISTICS (CONTROL INPUTS ONLY), ECL V
CCT
= + 5.0 ±10%, V
EE
= 4.2 V to 5.5 V
Symbol
T
A
= 0°C T
A
= 25°C T
A
= 75°C
Parameter Min Max Min Max Min Max Unit
V
IH
V
IL
Input HIGH Voltage
Input LOW Voltage
1165
1810
880
1475
1165
1810
880
1475
1165
1810
880
1475
mV
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
Table 7. DC CHARACTERISTICS, TTL V
CCT
= + 5.0 V ±10%, V
EE
= 5.2 ± 5% (10H Version);
V
EE
= 4.2 V to 5.5 V (100H Version)
Symbol
T
A
= 0°C T
A
= 25°C T
A
= 75°C
Parameter Condition Min Max Min Max Min Max Unit
V
IH
V
IL
Standard Input
Standard Input
2.0
0.8
2.0
0.8
2.0
0.8
Vdc
V
IK
Input Clamp I
IN
= 18 mA 1.2 1.2 1.2 Vdc
V
OH
Output HIGH Voltage
Output HIGH Voltage
I
OH
= 3.0 mA
I
OH
= 15 mA
2.5
2.0
2.5
2.0
2.5
2.0
V
V
OL
Output LOW Voltage I
OL
= 48 mA 0.55 0.55 0.55 V
I
IH
* TTL (Input HIGH)
TTL (Input HIGH)
V
in
= 2.7 V
V
in
= 7.0 V
20
100
20
100
20
100
mA
I
IL
* TTL (Input LOW) V
in
= 0.5 V 0.6 0.6 0.6 mA
I
CCL
Supply Current 75 75 75 mA
I
CCH
Supply Current 70 70 70 mA
I
CCZ
Supply Current 70 70 70 mA
I
OS
Output Short Circuit Current V
OUT
= 0 V 100 225 100 225 100 225 mA
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
*TTL Control Inputs only
Table 8. DC (I/O CHARACTERISTICS ONLY), TTL
Symbol
T
A
= 0°C T
A
= 25°C T
A
= 75°C
Parameter Condition Min Max Min Max Min Max Unit
I
IH/IOZH
I
IL/IOZL
Output Disable
Current
V
OUT
= 2.7 V
V
OUT
= 0.5 V
70
200
70
200
70
200
mA
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
MC10H680, MC100H680
http://onsemi.com
5
Table 9. ECL TO TTL DIRECTION / AC TEST
Symbol
T
A
= 0°C T
A
= 25°C T
A
= 75°C
Parameter Waveforms Condition Min Max Min Max Min Max Unit
t
PLH
t
PHL
Propagation Delay
to Output
2, 4 C
L
= 50 pF 2.7 4.8 2.7 4.8 2.7 4.8 ns
t
PZH
t
PZL
ECEB to Output
Enable Time
2, 5, 6 C
L
= 50 pF 3.5
3.5
6.5
6.0
3.5
3.5
6.5
6.0
3.7
3.7
6.7
6.4
ns
t
PHZ
t
PLZ
ECEB to Output
Disable Time
2, 5, 6 C
L
= 50 pF 3.5
3.5
8.6
6.5
3.5
3.5
8.6
6.5
3.7
3.7
8.8
7.3
ns
t
PZH
t
PZL
TCEB to Output
Enable Time
2, 5, 6 C
L
= 50 pF 5.7
5.4
7.7
6.9
5.7
5.4
7.7
6.9
5.9
5.9
7.9
7.4
ns
t
PHZ
t
PLZ
TCEB to Output
Disable Time
2, 5, 6 C
L
= 50 pF 4.0
4.0
8.5
5.8
4.1
4.2
8.4
6.0
4.2
4.7
8.3
6.5
ns
t
r
/t
f
1.0 to 2.0 Vdc 3 C
L
= 50 pF 0.4 1.5 0.4 1.5 0.4 1.5 ns
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
Table 10. TTL TO ECL DIRECTION / AC TEST
Symbol Waveforms
T
A
= 0°C T
A
= 25°C T
A
= 75°C
Parameter Condition Min Max Min Max Min Max Unit
t
PLH
t
PHL
Propagation Delay
to Output
1, 4
25 W to 2.0 V
1.8 4.6 1.8 4.6 2.0 4.9 ns
t
PLH
t
PHL
ECEB
to Output
1, 4
25 W to 2.0 V
2.9 5.1 3.0 5.2 3.4 5.7 ns
t
PLH
t
PHL
TCEB
to Output
1, 4
25 W to 2.0 V
3.4 6.3 3.5 6.6 3.8 7.4 ns
t
r
/t
f
Output Rise/Fall
Time 20%80%
1, 3
25 W to 2.0 V
1.0 3.4 1.0 3.4 1.0 3.4 ns
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
MC10H680, MC100H680
http://onsemi.com
6
Figure 2. Block Diagram
TOE
EOE
CONTROL INPUTS
ECL I/O
TTL I/O
V
EE
V
CCE
V
CCT2
V
CCT1
V
CCO1
GND1
V
CCO2
GND2
V
CCO3
GND3
GND4
V
CCO4
TIO3
EIO3
EIO3
TIO2
EIO2
EIO2
TIO1
EIO1
EIO1
ECE
TCE
EDIR
TDIR
TIO0
EIO0
EIO0
50 W COAX
V
EE
V
CC
& V
CCO
IN OUT
OSCILLOSCOPE
CH A
CH B
USE 0.1 mF CAPACITORS
FOR DECOUPLING.
DEVICE
UNDER
TEST
PULSE
GENERATOR
Figure 3. Switching Circuit ECL
ECL
DEVICE
UNDER
TEST
50 pF
R2
500 W
R1
500 W
ALL
OTHERS
+7 V OPEN
t
PZL
, t
PLZ
TTL
50 W
USE OSCILLOSCOPE
INTERNAL 50 W LOAD
FOR TERMINATION.
50 W COAX
50 W COAX
Figure 4.
SWITCHING CIRCUIT

MC10H680FNR2

Mfr. #:
Manufacturer:
ON Semiconductor
Description:
IC TRNSLTR BIDIRECTIONAL 28PLCC
Lifecycle:
New from this manufacturer.
Delivery: