ADCMP603 Data Sheet
Rev. A | Page 6 of 16
ABSOLUTE MAXIMUM RATINGS
Table 3.
Parameter Rating
Supply Voltages
Input Supply Voltage Range
(V
CCI
to GND)
−0.5 V to +6.0 V
Output Supply Voltage Range
(V
CCO
to GND)
−0.5 V to +6.0 V
Positive Supply Differential Range
(V
CCI
− V
CCO
)
−6.0 V to +6.0 V
Input Voltages
Input Voltage Range −0.5 V to V
CCI
+ 0.5 V
Differential Input Voltage ±(V
CCI
+ 0.5 V)
Maximum Input/Output Current ±50 mA
Shutdown Control Pin
Applied Voltage Range (HYS to GND)
CCO
Maximum Input/Output Current ±50 mA
Latch/Hysteresis Control Pin
Applied Voltage Range (HYS to GND) −0.5 V to V
CCO
+ 0.5 V
Maximum Input/Output Current ±50 mA
Temperature
Operating Ambient Temperature
Range
−40°C to +125°C
Operating Junction Temperature 150°C
Storage Temperature Range −65°C to +150°C
Stresses at or above those listed under Absolute Maximum
Ratings may cause permanent damage to the product. This is a
stress rating only; functional operation of the product at these
or any other conditions above those indicated in the operational
section of this specification is not implied. Operation beyond
the maximum operating conditions for extended periods may
affect product reliability.
THERMAL RESISTANCE
θ
JA
is specified for the worst-case conditions, that is, a device
soldered in a circuit board for surface-mount packages.
Table 4. Thermal Resistance
θ
JA
1
ADCMP603 LFCSP 12-lead 62 °C/W
1
Measurement in still air.
ESD CAUTION