8
MILITARY AND INDUSTRIAL TEMPERATURE RANGES
IDT54/74FCT162511AT/CT
FAST CMOS 16-BIT REGISTERED/LATCHED TRANSCEIVER
FCT162511AT FCT162511CT
Ind. Mil. Ind. Mil.
Symbol Parameter Test Conditions
(1, 3)
Min. Max. Min. Max. Min. Max. Min. Max. Unit
tSU Set-up Time GEN/CHK LOW PBx valid CL = 50pF 4 — 4 — 3 — 3.5 — ns
HIGH or LOW PBx not valid RL = 500Ω 3—3—3—3—ns
Ax to CLKAB GEN/CHK HIGH PERB valid 4 — 4 — 3 — 3 — ns
PERB not valid 3 — 3 — 3 — 3 — ns
tSU Set-up Time GEN/CHK HIGH PERB valid 4 — 4 — 3 — 3 — ns
PAx to CLKAB PERB not valid 3 — 3 — 3 — 3 — ns
tSU Set-up Time PERA valid 4 — 4 — 3 — 3 — ns
Bx to CLKBA, PERA not valid 3 — 4 — 3 — 3 — ns
PBx to CLKBA
tSU Set-up Time CLKAB LOW PBx valid 3.5 — 3.5 — 3 — 3 — ns
Ax to LEAB GEN/CHK LOW PBx not valid 3 — 3 — 3 — 3 — ns
CLKAB LOW PERB valid 3.5 — 3.5 — 3 — 3 — ns
GEN/CHK HIGH PERB not valid 3 — 3 — 3 — 3 — ns
CLKAB HIGH PBx valid 3.5 — 3.5 — 3 — 3 — ns
GEN/CHK LOW PBx not valid 3 — 3 — 3 — 3 — ns
CLKAB HIGH PERB valid 3.5 — 3.5 — 3 — 3 — ns
GEN/CHK HIGH PERB not valid 3 — 3 — 3 — 3 — ns
tSU Set-up Time CLKAB LOW PERB valid 3.5 — 3.5 — 3 — 3 — ns
PAx to LEAB GEN/CHK HIGH PERB not valid 3 — 3 — 3 — 3 — ns
CLKAB HIGH PERB valid 3.5 — 3.5 — 3 — 3 — ns
GEN/CHK HIGH PERB not valid 3 — 3 — 3 — 3 — ns
tSU Set-up Time CLKBA LOW PERA valid 3.5 — 3.5 — 3 — 3 — ns
Bx to LEBA PERA not valid 3 — 3 — 3 — 3 — ns
PBx to LEBA CLKBA HIGH PERA valid 3.5 — 3.5 — 3 — 3 — ns
PERA not valid 3 — 3 — 3 — 3 — ns
t
SK(O) Output Skew
(4)
— 0.5 — 0.5 — 0.5 — 0.5 ns
SWITCHING CHARACTERISTICS OVER OPERATING RANGE (SET UP TIMES)
FCT162511AT FCT162511CT
Ind. Mil. Ind. Mil.
Symbol Parameter Condition
(1)
Min. Max. Min. Max. Min. Max. Min. Max. Unit
tH Hold Time HIGH or LOW Ax to LEAB, Bx to LEBA CL= 50pF 1 — 1 — 1 — 1 — ns
tH Hold Time HIGH or LOW PAx to LEAB RL = 500Ω 1—1—1— 1—ns
tH Hold Time HIGH or LOW PBx to LEBA 1 — 1 — 1 — 1 — ns
tH Hold Time Ax to CLKAB, PAx to CLKAB 1 — 1 — 0 — 0 — ns
tH Hold Time Bx to CLKBA, PBx to CLKBA 1 — 1 — 0 — 0 — ns
tW LEAB or LEBA Pulse Width HIGH
(2)
3—3—3— 3—ns
tW CLKAB or CLKBA Pulse Width HIGH or LOW
(2)
3—3—3— 3—ns
SWITCHING CHARACTERISTICS OVER OPERATING RANGE (HOLD TIMES)
NOTES:
1. See test circuits and waveforms.
2. This parameter is guaranteed but not tested.
3. "Not valid" means the set-up time indicated is not sufficient to assure proper functioning of this output; however, the set-up time indicated will assure proper functioning of the
A to B or B to A port respective to the indicated direction.
4. Skew between any two outputs of the same package, switching in the same direction, excluding PERx in clocked mode, and Pxx (parity bits) and PERx in transparent/
latched mode. This parameter is guaranteed by design.