BPM15 Series
Encapsulated Isolated Wide Input Bipolar 15-Watt DC-DC Converters
MDC_BPM15.A02 Page 22 of 29
www.murata-ps.com/support
FUNCTIONAL SPECIFICATIONS, BPM15-150-Q48
ABSOLUTE MAXIMUM RATINGS
Conditions ➀
Minimum Typical/Nominal Maximum Units
Input Voltage, Continuous 075
Vdc
Input Voltage, Transient 100 mS max. duration 100
Vdc
Isolation Voltage Input to output 1600
Vdc
On/Off Remote Control Power on, referred to -Vin
0
15
Vdc
Output Power 1.485 15.15
W
Output Current
Current-limited, no damage, short-circuit
protected
0.05
0.5
A
Storage Temperature Range Vin = Zero (no power)
-55
125 ˚C
Absolute maximums are stress ratings. Exposure of devices to greater than any of these conditions may adversely affect long-term reliability. Proper operation under conditions other than those
listed in the Performance/Functional Specifi cations Table is not implied or recommended.
INPUT
Operating Voltage Range 18 48 75
Vdc
Recommended External Fuse Fast blow 2
A
Start-up Threshold Rising input voltage 16.25 16.8 17.5
Vdc
Undervoltage Shutdown (50% load) Falling input voltage 15 16 17
Vdc
Internal Filter Type C
Input Current
Full Load Input Current Vin = nominal 0.36 0.38
A
Low Line Input Current Vin = minimum 0.97 1.01
A
Inrush Transient 0.05 A2-Sec.
Short Circuit Input Current 0.05 0.1
A
No Load Input Current Iout = minimum, unit=ON 50 100
mA
Shut-Down Input Current (Off, UV, OT) 12
mA
Refl ected (Back) Ripple Current ➁
Measured at input with specifi ed fi lter 35
mA, p-p
GENERAL and SAFETY
Effi ciency
Vin = 48V, full load 83.0
86.0
%
Vin = min., full load 83.0
85.5
%
Isolation
Isolation Voltage Input to output
1600
Vdc
Isolation Resistance 10
M
Isolation Capacitance 700 pF
Safety
Certifi ed to UL-60950-1, CSA-C22.2 No.
60950-1, IEC/60950-1, 2nd edition, with AM1
Approved
Calculated MTBF
Per Telcordia SR332, issue 1, class 3, ground
fi xed, Tambient = +25°C
5
Hours x 10
6
DYNAMIC CHARACTERISTICS
Fixed Switching Frequency 290 320 350
KHz
Startup Time Power on to Vout regulated 50
mS
Startup Time Remote ON to Vout regulated 60
mS
Dynamic Load Response
50-75-50% load step, settling time to within
1% of Vout
250 300
µSec
Dynamic Load Peak Deviation same as above ±150 ±250
mV
FEATURES and OPTIONS
Remote On/Off Control ➂
“N” suffi x
Negative Logic, ON state ON = Ground pin
-0.7
0.8
V
Negative Logic, OFF state OFF = Pin open
10
15
V
Control Current Open collector/drain 1 mA
“P” suffi x
Positive Logic, ON state ON = Pin open
10
15
V
Positive Logic, OFF state OFF = Ground pin
-0.7
0.7
V